• Title/Summary/Keyword: internal standard

Search Result 1,907, Processing Time 0.035 seconds

Awareness and Performance on Standard Precautions of Hospital-acquired Infection Control in Nursing Students: The Mediating Effect of Internal Health Locus of Control (간호 대학생의 의료관련감염 관리에 대한 표준주의 인지도와 표준주의 수행도: 내적 건강통제위의 매개효과)

  • Yang, Sun-Yi;Lim, Hyo-Nam
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.23 no.4
    • /
    • pp.378-388
    • /
    • 2017
  • Purpose: The aim of this study was to identify the status of performance on standard precautions among nursing students and to examine the mediating effects of internal health locus of control on the relationship between awareness and performance on standard precautions of hospital-acquired infection control. Methods: The participants in this study were 134 nursing students. The measurements included a standard precautions awareness and performance scale, and a multidimensional health locus of control scale. Data were analyzed using independent t-test, one-way ANOVA, $Scheff{\acute{e}}$ test, Pearson correlation coefficient, and simple and multiple regression techniques. Mediation analysis was performed by the Baron and Kenny's method and Sobel test. Results: The mean score of standard awareness, standard performance, and internal health locus of control about standard precaution were $174.30{\pm}9.08$; $169.48{\pm}12.04$; and $20.43{\pm}2.82$; respectively. There was a positive correlation between standard awareness and performance (r=.414, p<.001). Also, standard awareness was significantly correlated with internal health locus of control (r=.413, p=.014). Internal health locus of control showed partial mediating effects in the relationship between awareness and performance. Conclusion: The results indicate a need to improve the internal health locus of control of nursing students. Therefore, an internal health locus of control improvement program should improve performance on standard precautions for patients and themselves.

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

Correlation Study between Electrogastrography and Nepean Dyspepsia Index (NDI) in Clinical Practice Students (임상실습 학생을 대상으로 한 위전도검사와 Nepean Dyspepsia Index(NDI) 설문검사와의 연관성 연구)

  • Choi, Jin-yong;Bae, Go-eun;Shim, So-hyun;Seo, Hee-jeong;Seo, Hyung-bum;Choi, Jun-yong;Kwon, Jung-nam;Lee, In;Hong, Jin-woo;Yun, Young-ju;Park, Seong-ha;Han, Chang-woo;Kim, So-yeon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.732-740
    • /
    • 2018
  • Objective: The aim of this study was to find a correlation between the Nepean Dyspepsia Index (NDI) and electrogastrography (EGG) in clinical practice students. Methods: In total, 28 students were enrolled. NDI and EGG were measured in all students. NDI was classified as abnormal when the score was 11 or more. In EGG, standard 1 was classified as abnormal if the preprandial or postprandial percentage of normal gastric slow waves of Ch3 was less than 70% or if power ratio of Ch3 was less than 1. Standard 2 was classified as abnormal if standard 1 was met or if the percentage of normal gastric slow waves of Ch3 decreased after meals. Results: NDI and EGG had no statistically meaningful correlation when standard 1 was used, but NDI and EGG had statistically meaningful correlation when standard 2 was used. Conclusions: These findings suggest that NDI and EGG are correlated and that EGG can be used to evaluate the degree of dyspepsia.

Precise Determination of Silicon in Ceramic Reference Materials by Prompt Gamma Activation Analysis at JRR-3

  • Miura, Tsutomu;Matsue, Hideaki
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.299-303
    • /
    • 2016
  • Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

Development of Multi-sample Loading Device for TEM Characterization of Hydroxyapatite Nanopowder

  • Lee, Jong-Moon;Kim, Jung-Kyun;Jeong, Jong-Man;Kim, Jin-Gyu;Lee, Eunji;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.788-792
    • /
    • 2013
  • A shortcoming of using transmission electron microscopy (TEM) for structural analysis via electron diffraction is the relatively large error of the measurements as compared to X-ray diffraction. To reduce these errors, various internal standard methods from earlier studies have been widely used. We developed a new device to facilitate the application of internal standard methods in preparation of TEM grids used for nanopowder analysis. Through the application of a partial mask on the TEM grid, both the internal standards and the research materials can be loaded on the same grid. Through this process, we conducted a TEM analysis that compared synthetic hydroxyapatite (HAp) nanopowder to bone apatite from a bovine femur. We determined that the accuracy of the d-spacing measurements of the HAp and bone powders could be improved to better than 1% after statistical treatments of the experimental data. By applying a quarter mask, we loaded four different nanoparticles on a single TEM grid, with one section designated for the internal standard.

An Investigation of Lattice Parameter Measurement of Inorganic Crystals by Electron Diffraction Patterns (전자회절도형을 이용한 무기시료의 격자상수 측정법 연구)

  • Lee, Young-Boo;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.75-81
    • /
    • 1999
  • Optimum conditions for making the Au and Al internal standards for TEM have been determined experimentally. The Au internal standard was produced by sputter coating at 9mA for 100 seconds in low vacuum $(\leq1\times10^{-3})$. The Al internal standard was produced by evaporation coating at 7kV for 10 minutes in high vacuum $(\leq1\times10^{-5})$. Measurements of the lattice parameters of andalusite and albite feldspars with this Au internal standard resulted in errors of (a) $ \leq1.2%$ in precion and $\leq0.3%$ in accuracy for andalusite: (b) $\leq0.5%$ in precision and $\leq1.1%$ in accuracy for albite feldspars. The most significant error occurred from the measuring processes of distances and angles of electron diffraction patterns. By employing systematic procedures of measurement with high precision devices, this lattice parameter determination method utilizing the internal standard should be a good alternative to the conventional powder XRD method or the sophisticated CBED method for special samples.

  • PDF

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

A study on internal morphological standard in Codonopsis Pilosulae Radix (黨參의 內部構造規格設定에 관한 硏究)

  • Kim, Baek-Cheol;Kang, Kyung-sic;Ju, Young-sung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.13 no.1
    • /
    • pp.253-266
    • /
    • 2000
  • In order to strengthen objectivity and availability of oriental herb medicine, the standard formula for herbs has been attempted to set up by experimenting and documentary testing original herbs which were recorded in authorized document. The object herb medicine is Codonopsis Pilosulae Radix. The internal and external morphological standard in this study is expected to supply the search for several physiochemical reaction, biological reaction, determination of indicator material and identification of gene with basic sources in the future. The result of study is as follows; In the external shape, it was possible that herbs were distinguished according to artificial classification and that same genus-degree of relatedness among herbs could be distinguished by more precise and active observation. In the shape of real herbs, I compared current herbs in market with original herbs which were just collected or were on the course of drying. In addition, it was possible that the internal shape could be identified by using microscope after butanol series. In powder herbs, it was possible to purify the shape by microscope through maceration of natural and powder herbs. Though it was impossible to make distinction of herbs which are not current in my search contents, this search contents will be a standard for alpplying herbs in the future. Despite such a useful character, it was difficult to deal with power herbs because it was uncertain to make a standard for them on account of the crush of these tissue. Since powders shape of herbs in a few documents were regard not as the powder shapes of natural herbs but as the maceration state of them. It is suggested that we should inspect the original herbs which are not crushed yet with a microscope in order to identify crushed shape of powder herbs from now on. An Additional standard establishment including physiochemical reaction and gene research is required in order to supplement the fault of this search. As for the supplement about this search, considering that many kinds of same genus-degree of relatedness are being current now, it is necessary that each herb should he collected only after identifying and that the succeeding search of each herb should be proceeded for the regular establishment of internal and external standard.

  • PDF