A Study on the Effect of GND Condition on CISPR25 Radiation Emission Test (GND조건이 CISPR25 복사방출 시험에 미치는 영향에 관한 연구)

  • Yoon, Jin-sang;Hong, ik-pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.404-407
    • /
    • 2018
  • - A car is a means of transporting passengers or cargo on the ground by transmitting power from the engine to the wheels. In the past, automobiles started from internal combustion engines have recently been introduced with hybrid electric vehicles and pure electric vehicles. As a result, the deployment of high-tech electrical and electronic products is inevitably increased due to the development of technology and stability of various parts, resulting in a more complicated and diversified electromagnetic environment. CISPR 25 is conducting research on the test method for electromagnetic noise. In order to analyze the noise pattern according to the GND condition required in the radiation emission test, various conditions are applied for comparison. 2 Page - General characteristics of EMI chambers, techniques for testing and measuring equipmen 3 Page - RE test : Analysis of Noise due to Ground Strap Change when Sample is in Center, Analysis of Noise due to Ground Strap Changes when the Sample is not in the Center.

  • PDF

Development of a CAN-based Real-time Simulator for Car Body Control

  • Kang, Ki-Ho;Seong, Sang-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.444-448
    • /
    • 2005
  • This paper presents a developing procedure of the CAN-based real-time simulator for car body control, aiming at replacing the actual W/H (Wiring Harness) and J/B(Junction Box) couple eventually. The CAN protocol, as one kind of field-bus communication, defines the lowest 2 layers of the ISO/OSI standard, namely, the physical layer(PL) and the data link layer(DLL), for which the CSMA/NBA protocol is generally adopted. For CPU, two PIC18Fxx8x's are used because of their built-in integration of CAN controller, large internal FLASH memory (48K or 64K), and their costs. To control J/B's and actuators, 2 controller boards are separately implemented, between which CAN lines communicate through CAN transceivers MCP255. A power motor for washing windshield, 1 door lock motor, and 6 blink lamps are chosen for actuators of the simulator for the first stage. For the software architecture, a polling method is used for the fast global response time despite its slow individual response time. To improve the individual response time and to escape from some eventual trapped-function loops, High/Low ports of the CPU are simply used, which increases the stability of the actuator modules. The experimental test shows generally satisfactory results in normal transmitting / receiving function and message trace function. This simulator based on CAN shows a promising usefulness of lighter, more reliable and intelligent distributed body control approach than the conventional W/H and J/B couple. Another advantage of this approach lies in the distributed control itself, which gives better performance in hard real-time computing than centralized one, and in the ability of integrating different modules through CAN.

  • PDF

Reliability and Validity of the Malay Version of the Breast-Impact of Treatment Scale (MVBITS) in Breast Cancer Women undergoing Chemotherapy

  • Zainal, Nor Zuraida;Shuib, Norley;Bustam, Anita Zarina;Sabki, Zuraida Ahmad;Guan, Ng Chong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.463-468
    • /
    • 2013
  • Background: Body image dissatisfaction among breast cancer survivors has been associated with psychological stress resultant from breast cancer and resultant surgery. This study aimed to examine the psychometric properties of the Malay Version of the Breast-Impact of Treatment Scale (MVBITS) and to investigate the associations of retained factors with the Hospital Anxiety and Depression Scale (HADS) and the Rosenberg Self-Esteem Scale (RSES). Materials and Methods: The MVBITS was 'forward-backward' translated from English to Malay and then administered to 70 female breast cancer patients who came to the Oncology Clinic of University Malaya Medical Centre, Kuala Lumpur, Malaysia to undergo chemotherapy. Principal component analysis (PCA) with varimax rotation was performed to explore the factor structure of the MVBITS. Associations of retained factors were estimated with reference to Spearman correlation coefficients. Results: The internal consistency reliability of MVBITS was good (Cronbach's alpha 0.945) and showed temporal stability over a 3-week period. Principal component analysis suggested two factors termed as 'Intrusion' and 'Avoidance' domains. These factors explained 70.3% of the variance. Factor 1 comprised the effects of breast cancer treatment on the emotion and thought, while Factor 2 informed attempts to limit exposure of the body to self or others. The Factor 1 of MVBITS was positively correlated with total, depression and anxiety sub-scores of HADS. Factor 2 was positively correlated with total and anxiety sub-scores of HADS. MVBITS was also positively correlated with the RSES scores. Conclusions: The results showed that the Malay Version of Breast-Impact of Treatment Scale possesses satisfactory psychometric properties suggesting that this instrument is appropriate for assessment of body change stress among female breast cancer patients in Malaysia.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

Study on the validation methods of calibration considering correlations (상관관계를 반영한 신용등급 계량화 검정기법 연구)

  • Kim, Enn-Na;Ha, Jeong-Cheol
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.3
    • /
    • pp.407-417
    • /
    • 2010
  • In Basel II compliance, internal rating systems are allowed for banks to enhance the self control and the validation of the system are getting more important. The validation methods are composed of qualitative test and quantitative test, three basic standards of which are discriminatory power, stability and calibration. The aim of this article is to review the quantitative tests for calibration and find a new method for it. These methods for discrimination between forecasted PD and observed PD include binomial test, chi square test, Brier score, traffic lights approach, normal test and extended traffic lights approach. We introduce a modified extended traffic lights approach considering asset correlations.

Effect of Contralateral Hip Adduction on Muscle Thicknesses of Lumbar Stabilizers and Pelvic Lateral Tilting During Hip Abduction in Side-lying (옆으로 누운 자세에서 고관절 외전시 반대 측 고관절 내전이 요추안정화 근육 두께와 골반 외측 경사에 미치는 영향)

  • Kim, Hyo-Uen;Choi, Bo-Ram;Kim, Su-Jung;Lee, Won-Hwee;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The purpose of this study was to determine the effect of contralateral hip adduction (CHA) on thickness of lumbar stabilizers during hip abduction in side-lying. Twenty healthy subjects without back pain were recruited for this study. The thickness of transverse abdominis (TrA), internal oblique (IO) and quadratus lumborum (QL) were measured by ultrasonography. Pelvic lateral tilting motion was measured using a three-dimensional motion analysis system. Measurements were performed at rest position (RP), $35^{\circ}$preferred hip abduction (PHA) and $35^{\circ}$abduction with $10^{\circ}$contralateral hip adduction (CHA) in side-lying at the end of expiration. During the measurements, subjects were asked to maintain steady trunk alignment without hand support. Thickness of TrA and IO was significantly greater in CHA than in PHA and RP conditions. There was no significant difference in thickness of TrA and IO between PHA and RP conditions. Medio-lateral (M-L) thickness of QL was not significant between PHA and CHA conditions. Anterio-posterior (A-P) thickness of QL in PHA and CHA significantly decreased compared to RP condition. Angle of pelvic lateral tilting was significantly decreased in CHA compared to PHA condition. In conclusion, CHA can be recommended for increasing trunk stability without compensatory pelvic motion during hip abduction exercise in side-lying.

EMG Activity of Abdominal Muscles During Lumbopelvic Stabilization Exercises (척추 안정화 운동 방법들에 따른 배근육의 근 활성도 비교)

  • Lee, Gyu-Wan;Yoon, Tae-Lim;Kim, Ki-Song;Lee, Ji-Hyun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • Lumbopelvic stabilization exercise has become the most popular treatment method in lumbar rehabilitation since its effectiveness was shown in some aspects of pain and disability. The abdominal drawing-in maneuver (ADIM) has been extensively implemented to promote lumbopelvic stability. However, performing ADIM correctly is difficult even for healthy subjects, and it is time consuming to train people in ADIM. Thus, the purpose of this study was to compare abdominal muscle [rectus abdominalis (RA), external oblique (EO), and transverse abdominis/internal oblique (TrA/IO)] activity during lumbopelvic stabilization exercises (ADIM only, ADIM with a ball, maximum exhalation only, and maximum exhalation with a ball) performed in a supine position with feet against a wall. Fifteen healthy subjects were recruited for this study. Surface electromyography was used to measure abdominal muscle activity during lumbopelvic stabilization exercises. A one-way repeated-measures analysis of variance was used to determine the statistical significance of RA, EO, and TrA/IO muscle activity during four lumbopelvic stabilization exercises. Both-side TrA/IO muscle activity was significantly greater with maximum exhalation with a ball than with ADIM only or ADIM with a ball (p<.008). The results of this study suggest that maximum exhalation with a ball can be used as an effective lumbopelvic stabilization exercise to increase TrA/IO muscle activity in healthy subjects.

A Three-Dimensional Numerical Model of Hydrodynamic Flow on σ-Coordinate (연직변환좌표(鉛直變換座標)에서 3차원(次元) 유동(流動) 수직모형(數値模型))

  • Jung, Tae Sung;Lee, Kil Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1145-1158
    • /
    • 1994
  • A three-dimensional, finite difference, numerical model with free surface was developed on ${\sigma}$-coordinate. A semi-implicit numerical scheme in time has been adopted for computational efficiency. The scheme is essentially independent of the stringent stability criteria (CFL condition) for explicit schemes of external surface gravity wave. Implicit algorithm was applied for vertical shear stress, Coriolis force and pressure gradient terms. The reliability of the model with vertically variable grid system was checked by the comparison of simulation results with analytic solution of wind-driven currents in a one-dimensional channel. Sensitivity analysis of differencing parameters was carried out by applying the model to the calculation of wind-driven currents in a square lake.

  • PDF

A Study on the Organizational Culture of University Libraries (대학도서관 조직문화에 관한 연구)

  • Yoon, Hye-Young
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.4
    • /
    • pp.97-121
    • /
    • 2000
  • This study attempts to identify a profile of the university library's overall organizational culture and to analyze the difference of the organizational culture according to library's characteristics(size, location, control and unit). A questionnaire that is based on the competing values framework is used to survey staff in university library. In conclusion, the highest score is in the internal process quadrant(39.92), toward consolidation and continuity, but emphasizing control aimed at stability. And the weakest in the overall culture profile is the open systems quadrant(13.27) which may indicate that external support and resource acquisition are not strong measures of effectiveness to the staff. Research on university library organizational culture using both qualitative and quantitative method needs to be further considered. Furthermore, the strategy in library organizational culture for library administrator to manage human resources efficiently needs to be developed.

  • PDF

Development and Psychometric Evaluation of the Patient Safety Violation Scale in Medical Oncology Units in Iran

  • Shali, Mahboobeh;Ghaffari, Fatemeh;Joolaee, Soodabeh;Ebadi, Abbas
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4341-4347
    • /
    • 2016
  • Background: Patient safety is one of the key components of nursing care for cancer cases. Valid and reliable context-based instruments are necessary for accurate evaluation of patient safety in oncology units. The aim of the present study was to develop and evaluate the psychometric properties of the Patient Safety Violation Scale in medical oncology units in Iran. Materials and Methods: In this methodological study, a pool of 58 items was generated through reviewing the existing literature. The validity of the 58-item scale was assessed through calculating impact score, content validity ratio, and content validity index for its items as well as conducting exploratory factor analysis. The reliability of the scale was evaluated by assessing its internal consistency and testretest stability. Study sample consisted of 300 oncology nurses who were recruited from thirteen teaching hospitals affiliated to Tehran University of Medical Sciences, Tehran, Iran. Results: Sixteen items were excluded from the scale due to having low impact scores, content validity ratios, or content validity indices. In exploratory factor analysis, the remaining 42 items were loaded on five factors including patient fall, verification of patientidentity, harm during care delivery, delay in care delivery, and medication errors. These five factors explained 62% of the total variance. The Cronbach's alpha of the scale and the test-retest interclass correlation coefficient were equal to 0.933 and 0.92, respectively. Conclusions: The 42-item Patient Safety Violation Scale is a simple and short scale which has acceptable validity and reliability. Consequently, it can be used for assessing patient safety in clinical settings such as medical oncology units and for research projects.