• Title/Summary/Keyword: internal parameter

Search Result 528, Processing Time 0.027 seconds

Off-Line Parameter Identification of Permanent Magnet Synchronous Motor Using a Goertzel Algorithm

  • Yoon, Jae-Seung;Lee, Kyoung-Gu;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2262-2270
    • /
    • 2015
  • Generally, internal parameters of the motors and generators can be divided to the resistance and inductance components. They can become a cause of the changing internal parameters because they have sensitive characteristics due to external conditions. The changed parameters can generate the outputs which include error values from the speed and current controllers. Also, it can bring the temperature increase and mechanical damage to the system. Therefore, internal parameters of the motors and generators need to obtain their values according to the external conditions because it can prevent the mechanical damage caused by the changed parameters. In this paper, the off-line parameter identification method is verified using the Goertzel algorithm. The motor used in the simulation and experiments is an interior permanent magnet synchronous motor (IPMSM), and the proposed algorithm is verified by the simulation and experimental results.

Robust independent control for position motion-inducing force, and internal force of multi-robot (다중 로보트의 위치, 운동야기힘과 내부힘의 강건 독립 제어)

  • 김종수;박세승;박종국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.11-21
    • /
    • 1996
  • Robot manipulators constituing multi-robot system must exert the desired motion force on an object to preserve tghe fine motion of it. The forces exerte on an object by the end-effectors of multi-inducing force and the internal force. Here, motion-inducing force effects the motion of an object, but internal force as lies in the null space of an object coordinate can't effect it. The motion of an object can't track exactly the desired motion by the effect of an object, but internal force as lies in the null space of the effect of internal force component, therefore internal force component must be considered. In this paper, first, under assumption that we can estimate exactly the parameter of dynamics, we constitute paper, first, under assumption that we can estimate exactly the parameter of dynamics, we constitute the controller concerning internal force. And we obtain the internal force as projecting force sensor readings onto the space spanned by null basis set of jacobian matrix. Using the resolved acceleration control method and the fact that internal force lies in the null space of jacobian matrix, we construct the robust control law to preserve the robustness with respect to the uncertainty of mainpulator parameters.

  • PDF

A Study on Measurement and Control of position and pose of Mobile Robot using Ka13nan Filter and using lane detecting filter in monocular Vision (단일 비전에서 칼만 필티와 차선 검출 필터를 이용한 모빌 로봇 주행 위치.자세 계측 제어에 관한 연구)

  • 이용구;송현승;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.81-81
    • /
    • 2000
  • We use camera to apply human vision system in measurement. To do that, we need to know about camera parameters. The camera parameters are consisted of internal parameters and external parameters. we can fix scale factor&focal length in internal parameters, we can acquire external parameters. And we want to use these parameters in automatically driven vehicle by using camera. When we observe an camera parameters in respect with that the external parameters are important parameters. We can acquire external parameter as fixing focal length&scale factor. To get lane coordinate in image, we propose a lane detection filter. After searching lanes, we can seek vanishing point. And then y-axis seek y-sxis rotation component(${\beta}$). By using these parameter, we can find x-axis translation component(Xo). Before we make stepping motor rotate to be y-axis rotation component(${\beta}$), '0', we estimate image coordinates of lane at (t+1). Using this point, we apply this system to Kalman filter. And then we calculate to new parameters whick make minimum error.

  • PDF

Correlation between Trunk Stabilization Muscle Activation and Gait Parameters (몸통 안정화 근육과 보행요소의 상관관계)

  • Chae, Jung-Byung;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Purpose: This study aimed to investigate the correlation between trunk stabilization muscle activation and the parameters of gait analysis in healthy individuals. Methods: Thirty healthy adults (15 male, 15 female) with no history of lower back pain (LBP) or current musculoskeletal and neurological injuries were studied. Trunk stabilization muscle activation (e.g., external oblique, internal oblique, transverse abdominis, erector spinae) were assessed using surface electromyography. To analyze gait, we measured temporal parameters (e.g., gait velocity, single support phase, double support phase, swing phase, and stance phase) and a spatial parameter (e.g., H-H base of support). Results: A statistically significant correlation was found between the internal oblique, transverse abdominis, and erector spinae muscle activity and gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique muscle activity and the gait velocity, single support phase, double support phase, swing phase, and stance phase. No statistically significant correlation was found between the external oblique, internal oblique, transverse abdominis, and erector spinae muscle activity and the spatial parameter. Conclusion: This study demonstrated that a relationship exists between trunk stabilization muscle activation and temporal parameter (i.e., gait velocity, single support phase, double support phase, swing phase, and stance phase) during gait analysis. Therefore, the trunk's stabilizer muscles play an important role in the gait of healthy individuals.

Optimal Excitation Trajectories for the Dynamic Parameter Identification of Industrial Robots by Using Combined Model (통합모델과 최적 경로설계를 통한 산업용 로봇 동적 매개변수 규명)

  • Park, K.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.55-61
    • /
    • 2008
  • This paper discusses the advantages of using Fourier-based periodic excitation and of combining internal and external models in dynamic robot parameter identification. Internal models relate the joint torques or forces with the motion of the robot; external models relate the reaction forces and torques on the bedplate with the motion data. This combined model allows to combine joint torque/force and reaction torque/force measurements in one parameter estimation scheme. This combined model estimation will yield more accurate parameter estimates, and consequently better predictions of actuator torque, which is shown by means of a simulated experiment on a CRS A465 industrial robot.

  • PDF

A Generalized Modal Analysis for Multi-Stepped, Distributed-Parameter Rotor-Bearing Systems (다단 연속 회전체 베어링 계의 일반화된 모드 해석)

  • 박종혁;홍성욱
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.525-534
    • /
    • 1999
  • The present paper proposes a generalized modal analysis procedure for non-uniform, distributed-parameter rotor-bearing systems. An exact element matrix is derived for a Timoshenko shaft model which contains rotary inertia, shear deformation, gyroscopic effect and internal damping. Complex coordinates system is adopted for the convenience in formulation. A generalized orthogonality condition is provided to make the modal decomposition possible. The generalized modal analysis by using a modal decomposition delivers exact and closed form solutions both for frequency and time responses. Two numerical examples are presented for illustrating the proposed method. The numerical study proves that the proposed method is very efficient and useful for the analysis of distributed-parameter rotor-bearing systems.

  • PDF

Visual Inspection of Tube Internal

  • Choi, Young-Soo;Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.789-792
    • /
    • 2003
  • Pipe inspection has a great importance to ensure safety for the nuclear power plant. In this paper, we designed visual inspection module for the tube internal, which diameter is 15${\sim}$20mm. And we made inspection module which consisted of CCD camera and light. And the relation between image and real world coordinate is established. Image processing is performed to calculate mapping parameter and analyze the size of defect. For the calculation of mapping parameter, experiment is performed using grid type test pattern. Acquired image is processed to extract image coordinate. Edge detection, thresholding, median filtering and morphology filtering is applied to extract grid pattern. Extracted image coordinate is used to calculate image to real world mapping. Lens distortion was considered and corrected to get exact data. Coordinate transformation data is provided for the users to recognize easily. Experiment was performed using grid type test pattern, we extracted lens distortion parameter and real coordinate of defect point. Radial distortion of lens was corrected but tangential distortion was not considered. As continuum to this study, the tangential distortion of lens is considered and improvement of analy zing technique for the tube internal be explored continuously.

  • PDF

A Diagnostic Significance of Pleural Fluid Cholesterol Level (흉막액 Cholesterol 농도에 대한 진단적 의의)

  • Kim, Young-Kyoon;Kwon, Soon-Seog;Kim, Kwan-Hyoung;Han, Ki-Don;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.3
    • /
    • pp.262-269
    • /
    • 1991
  • The purpose of this study is to investigate the utility of the pleural fluid cholesterol level in separating the exudates from the transudates, and in differentiating tuberculous exudates from non-tuberculous exudates, 52 patients with pleural effusion were involved in this prospective study. By predefined criteria, 40 of these effusions were classified as exudates (Group I) and 12 as transudates (Group II). Group I was subdivided into tuberculous exudates (Group A) and non-tuberculous exudates (Group B). The followings are parameters used in separating the exudates from the transudates; pleural protein (P-PROT) 3.0 g/dl, pleural protein/serum protein ratio (P/S PORT) 0.5, pleural LDH (P-LDH) 200 IU, pleural LDH/serum LDH ratio (P/S LDH) 0.6, pleural cholesterol (P-CHOL) 50 mg/dl and pleural cholesterol/serum cholesterol ratio (P/S CHOL) 0.4. Mean values of the parameters in each group were compared, and then misclassified rate and the dignostic efficiency for each parameter were calculated. The results were as follows; 1) Mean P-CHOL ($94.98{\pm}73.86\;mg/dl$) in Group I was higher than that ($36.5{\pm}26.5\;mg/dl$) in Group II (p<0.05), but there was no significant difference in mean P-CHOL between Group A and Group B. 2) Mean P/S CHOL ($0.64{\pm}0.39$) in Group I was also higher than that ($0.27{\pm}0.15$) in Group II (p<0.01), but no difference was observed in mean P/S CHOL between Group A and Group B. 3) Misclassified rates for each parameter in separating the exudates from the transudates were as follows; P-PROT 1.9%. P/S PROT 3.8%. P-CHOL 9.6%, P/S CHOL 11.5%, P/S LDH 11.5%, and P-LDH 17.3%. 4) Diagnostic efficiencies for each parameter in separating the exudates from the transudates were as follows; P-PROT 98.1%, P/S PROT 96.2%. P-CHOL 90.4%. P/S CHOL 88.5%, P/S LDH 88.5%, and P-LDH 82.7%. In conclusion, we think that the pleural fluid chloesterol level could be used as a supportive parameter in separating the exudates from the transudates, but could not be used as a parameter in differentiating tuberculous exudates from non-tuberculous exudates.

  • PDF

Evolution of sandstone shear strength parameters and its mesoscopic mechanism

  • Shi, Hao;Zhang, Houquan;Song, Lei
    • Geomechanics and Engineering
    • /
    • v.20 no.1
    • /
    • pp.29-41
    • /
    • 2020
  • It is extremely important to obtain rock strength parameters for geological engineering. In this paper, the evolution of sandstone cohesion and internal friction angle with plastic shear strain was obtained by simulating the cyclic loading and unloading tests under different confining pressures using Particle Flow Code software. By which and combined with the micro-crack propagation process, the mesoscopic mechanism of parameter evolution was studied. The results show that with the increase of plastic shear strain, the sandstone cohesion decreases first and then tends to be stable, while the internal friction angle increases first, then decreases, and finally maintains unchanged. The evolution of sandstone shear strength parameters is closely related to the whole process of crack formation, propagation and coalescence. When the internal micro-cracks are less and distributed randomly and dispersedly, and the rock shear strength parameters (cohesion, internal friction angle) are considered to have not been fully mobilized. As the directional development of the internal micro-fractures as well as the gradual formation of macroscopic shear plane, the rock cohesion reduces continuously and the internal friction angle is in the rise stage. As the formation of the macroscopic shear plane, both the rock cohesion and internal friction angle continuously decrease to a certain residual level.

Parametric Analysis of the Slosh Motion of Internal Mass in a Space Vehicle

  • Kang, Ja-Young
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.04a
    • /
    • pp.95-95
    • /
    • 2004
  • The objectives of this study are to perform extensive analysis on internal mass motion for a wider parameter space and to provide suitable design criteria for a broader applicability for the class of spinning spacecraft. In order to examine the stability criterion determined by an analytical method, some numerical simulations will be performed and compared at various parameter points. (omitted)

  • PDF