• Title/Summary/Keyword: interleaving

Search Result 257, Processing Time 0.027 seconds

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF

High Efficiency of Grid-Connected Modular Photovoltaic Power Conversion Device (계통연계형 모듈형 태양광 전력변환 장치 고 효율화)

  • Lee, Seung-min;Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.269-270
    • /
    • 2012
  • 이 논문에서는 Fly-Back-Converter로 Interleaving 동작하는 계통연계형 마이크로 인버터를 연구하고 200W급 태양전지 모듈에서 발생되는 전기에너지를 효율적으로 이용하여 계통에 연계하기 위한 전력변환시스템 개발을 목표로 하고 있다. 저렴하면서 효율이 높은 계통연계 인버터를 실현하기 위해서는 기존의 중앙집중식 인버터 구조와 다른 접근이 필요하다. 따라서 영전위 소프트 스위칭이 가능한 2병렬 인터리빙 구동의 Fly-Back DC/DC 컨버터 토폴로지로 입력 단 회로를 구성하여 모든 전력변환 동작이 일어나도록 한다. 출력전류를 사인파 open loop로 제어를 하고 CRM(Critical Conduction Mode) 스위칭 동작으로 높은 효율로 작동을 실현시켰다. 이 논문에서는 인터리빙으로 동작하였을 시 200W급 출력으로 나올 수 있는 전류 최대치를 계산 하였고 출력 전류가 사인파로 동작하게 제어방법을 기재하였다.

  • PDF

Implementation of interleaved Critical mode Flyback type DC-AC inverter using digital controller (디지털 제어를 이용한 Interleaving CRM 플라이백 타입 DC-AC 인버터의 구현)

  • Kim, J.T.;Lee, K.C.;Seo, G.S.;Hyeon, B.C.;Bae, H.S.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.13-14
    • /
    • 2010
  • 본 논문에서는 경계 모드(Critical Mode) 플라이백 타입의 DC-AC 인버터에 인터리빙을 적용한 디지털 제어를 제안한다. 연속모드(CCM)나 불연속모드(DCM)와 달리 경계 모드의 경우 주파수가 가변되기 때문에 인터리빙으로 구현하기는 상당히 까다로운 측면이 있다. 또한 아날로그 제어기로 구현에 한계를 지니기 때문에 보다 간편한 구현을 위해 디지털 제어IC을 이용하여 구현하는 방법에 대해 기술한다. 본문에서 200W급 플라이백 타입의 DC-AC 인버터에 경계모드 인터리빙을 방법을 적용한 후 실험으로 검증한다.

  • PDF

A Power Line Communication System using Interleaving Method for Impulse Noise cancellation (임펄스 잡음 문제의 해결을 위한 인터리빙 기반의 전력선 통신시스템)

  • Moon K. H.;Shin M. C.;Seo H. S.;Choi S. Y.;Choi I. H.;Choi I. H.;Ko E. Y.;Lee J. J.;Cha J. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.316-318
    • /
    • 2004
  • 전력선통신에서 발생하는 잡음 중에 가장 중요한 잡음원이 바로 임펄쓰 잡음이다. 일반적으로 임펄스 잡음은 차단기나 모터의 개폐 시 등, 갑자기 발생하는 잡음으로 연집성 오류를 발생시키기도 하며. 오류발생에 대한 예측이 어려워 대처하기가 까다롭다. 본 논문에서 연집성 임펄쓰 잡음을 해결하기 위한 방안으로서 신호 변환 기술인 인터리빙 덴 디인터리빙 기법을 전력선 통신시스템에 적용하고, 모의실험을 통하여 그 신뢰성 및 유용성을 검토하였다.

  • PDF

Performance Improvement In Broadband Networks Using Forward Error Correction For Cell Loss Recovery (광대역 통신망에서 Forward Error Correction을 이용한 셀손실 회복의 성능 개선)

  • Lim Hyo-Taek;Song Joo-Seok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.6 no.3
    • /
    • pp.3-10
    • /
    • 1996
  • We present a method to recover consecutive cell losses using forward error correction(FEC) in ATM networks. Our method recovers up to 18 consecutive cell losses. Also, we present the performance estimation of the FEC technique using the interleaving in ATM networks. Performance estimation shows an outstanding reduction in cell loss rate.

Cryptanalysis of Bresson-Chevassut-Essiari-Pointcheval′s Key Agreement Scheme for Low-Power Mobile Devices (Bresson-Chevassut-Essiari-Pointcheval의 저전력 모바일 장치를 위한 키 동의 방식의 안전성 분석)

  • Nam Junghyun;Lee Younggyo;Kim Seungioo;Won Dongho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2005
  • Bresson et al. have recently proposed an efficient group key agreement scheme well suited for a wireless network environment. Although it is claimed that the proposed scheme is provably secure under certain intractability assumptions, we show in this paper that this claim is unfounded, breaking the allegedly secure scheme in various ways.

A New Soft-Switching Three-Level Flying Capacitor Converter (새로운 소프트스위칭 3레벨 Flying Capacitor 컨버터)

  • Kim, Jae-Hoon;Kim, Sun-Ju;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.484-489
    • /
    • 2020
  • This study proposes a new soft-switching three-level flying capacitor converter with low filter inductance. The proposed converter can achieve zero voltage switching (ZVS) turn-on of all switches by using auxiliary components La and Ca. It can also reduce filter inductance because the applied voltage of the filter inductor is decreased by using the flying capacitor. Furthermore, filter inductance can be reduced because the operating frequency of the filter inductor is doubled by the phase shifting between switches S3 and S4. The operation principle, design of passive components for ZVS turn-on, interleaving effects, and comparison of different topologies are presented. The experimental waveforms of a 1 kW two-phase interleaved converter prototype are provided to verify the validity of the proposed converter.

Comparative Analysis of Parallel System Interleaving Performance of Power Compensator for AC Electric Railway (교류전기철도용 전력보상장치의 병렬 시스템 인터리빙 성능 비교분석)

  • Woo, Jehun;Kim, Jichan;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.121-123
    • /
    • 2020
  • 본 논문은 단상 3레벨 조건에서 unipolar 및 bipolar PWM의 구현 및 동작에 대해 서술하였으며, 교류전기철도용 전력보상장치의 병렬 운전 상황에서 unipolar PWM과 bipolar PWM에 따른 인터리빙 효과에 대해 비교하였다. 또한, unipolar PWM 조건에서 전력보상장치의 3병렬과 4병렬 시스템의 인터리빙 결과에 대해 비교하였다. 이를 통해 단상 unipolar PWM을 사용한 병렬 시스템의 인터리빙이라는 특수한 조건에서는 PWM 캐리어의 180° phase shift가 포함되는 2병렬 및 4병렬의 경우 마치 bipolar PWM처럼 동작하여 스위칭 리플의 저감효과가 기대한 결과보다 낮음을 확인하였다. 따라서 스위칭 리플의 저감 측면만을 고려한다면 전력보상장치의 병렬 시스템은 180° 캐리어가 포함된 4병렬 시스템보다 120° 캐리어를 사용하는 3병렬 시스템이 유리한 것을 확인하였다.

  • PDF

Formal Analysis of the Extreme Interleaving on Concurrent Program (병행 프로그램에서 극단적 인터리빙의 정형 분석)

  • Park, Sa-Choun;Kwon, Gi-Hwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.375-377
    • /
    • 2008
  • 프로그램을 작성할 때 시스템의 성능을 높이기 위해서, 여러 개의 프로세스가 동시에 동작하고 상호작용하는 병행 프로그램을 사용한다. 병행 프로그램에서 프로세스들은 인터리빙 방식으로 동작하는 경우가 많다. 그런데 인터리빙을 잘 못 이해할 경우 프로그램에 오류가 생길 가능성이 높고 이러한 오류는 직관적으로 납득하지 못할 때도 많다. 본 논문에서는 인터리빙이 발생하는 최악의 경우를 소개하고 이를 SMV와 Spin 그리고 LTS-BMC로 정형 분석하는 방법에 대해서 설명한다. 또한 실험을 통해서 우리가 만든 LTS-BMC 도구가 병행 오류 검증에 효과적임을 알 수 있었다.

Mineralogical Characteristics and Genesis of Phlogopite in the Talc Deposits of the Chungnam Area, Korea (충남지역 활석광상에서 산출되는 금운모의 광물특성 및 기원)

  • Kim Geon-Young;Kim Soo Jin;Koh Yong Kwon;Bae Dae Seok
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.221-233
    • /
    • 2004
  • Mineralogical characteristics and genesis of phlogopite in the talc deposits of the chungnam area were studied. Mica is one of the major impurity of talc ores in the study area. Talc-related micas show typical phlogopite composition, whereas talc-unrelated micas show wide compositional variations between biotite and phlogopite. Phlogopite mainly occurs in the black-wall type zone, especially in the nodular talc ores near the outer part of talc ore bodies. Interleaving textures of phlogopite and chlorite are easily observed under the optical microscope and back-scattered electron images. Interleaving textures of phlogopite and talc are observed also. Examination of the phlogopite by transmission electron microscope reveals that 14 $\AA$ layers of chlorite are randomly interlayered within the 10 $\AA$ layers of phlogopite, which suggests that the genesis of phlogopite is closely related to chlorite. Considering the occurrence and mineralogical characteristics of phlogopite, and the possible origin of K for the formation of phlogopite, phlogopite of the study area was formed by interaction between talc ore body and hydrothermal solution containing sufficient K at the late stage of talc formation. K might be introduced from the granitic gneiss at the contact zone between the talc ore body and the granitic gneiss under favorable structural condition for the potash metasomatism.