• 제목/요약/키워드: interior column

검색결과 198건 처리시간 0.022초

베라이트 시멘트를 이용한 고강도 철근콘크리트 보-기둥 접합부의 이력특성 (Hysteretic Behavior of RC Beam-Column Joint for High Strength Structures using Belite Cement)

  • 배흥한;이상원;윤정배;김기수;이세웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.582-588
    • /
    • 1998
  • The experimental study for the interior beam-column joint for high strength conccrete using Belite cement is presented. Test parameters are compressive strength, flexual strength ratio and joint shear stresslevel. The results from cyclic loading tests show different behaviors from the various parameters. Also, The different behaviors on beam-column joint can be achived by the different concrete strength.

  • PDF

기둥 형상비에 따른 플랫 플레이트 기둥-슬래브 접합부의 거동특성 (Seismic Behavior of Column-Slab Connections with Different Column Aspect Ratio)

  • 천영수;이현호;이도범;김진수;허무원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.30-33
    • /
    • 2006
  • The purpose of this research is to study the seismic behavior of interior column-slab connections with different column aspect ratio, when subjected to combined gravity and cyclic lateral loading. The control specimen had square column, while the other specimens had rectangular column with aspect ratio of 0.5 and 2.0. From the test results, all of the specimens sustain lateral drifts as high as 4% with no more than a 20% decrease in peak lateral load capacity. And it appears that KBC Code(2005) procedure may be unconservative for connections with different column aspect ratio.

  • PDF

슬래브-기둥 접합부의 전단보강상세에 관한 연구 (A Study of Shear Reinforcement for Slab-Column Connection)

  • 백성우;김준서;최현기;최창식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.37-40
    • /
    • 2008
  • The study is an experimental test on full-scale flat plate slab-column interior connection. The punching shear on the flat plate slab-column connection can bring about the reason of the brittle punching shear failure which may result of collapsing the whole structure. From the development of residential flat plate system, the shear reinforcement is developed for preventing the punching shear. For making sure of the punching shear capacity, developed for shear reinforcement in slab-column connection, the structural test is performed. The dimension of the slabs was 2620*2725*180mm with square column (600*800mm). The slabs were tested up to failure monotonic vertical shear forces. The presences of S/S bar and wire mesh substantially increased the punching shear capacity and the ductility of the slab-column connections.

  • PDF

전단 보강 슬래브-기둥 내부 접합부 및 기초판에 대한 뚫림 전단강도 모델 (Direct Punching Shear Strength Model for Interior Slab-Column Connections and Column Footings with Shear Reinforcement)

  • 최경규;김석환;김동훈;박홍근
    • 콘크리트학회논문집
    • /
    • 제23권2호
    • /
    • pp.159-168
    • /
    • 2011
  • 이 연구에서는 뚫림 전단을 재하받는 전단 보강/전단 무보강 슬래브-기둥 내부 접합부와 기초판에 대하여 개선된 설계 방법을 개발하였다. 슬래브-기둥 접합부와 기초판의 다양한 파괴 메커니즘(경사 인장 균열 파괴, 전단 보강근의 항복, 콘크리트 압축대/스트럿의 압축 파괴)을 고려하여 뚫림 전단강도를 산정하였다. 콘크리트 위험 단면에 작용하는 뚫림 전단은 대부분 콘크리트 압축대에 의하여 지지된다고 가정하였으며, 콘크리트 압축대의 뚫림 전단강도는 압축 수직 및 전단의 조합 응력을 재하받는 콘크리트 재료 파괴 기준에 근거하여 산정하였다. 제안된 강도 모델은 실험 결과 와의 비교를 통하여 검증하였다. 검증 결과, 제안된 설계 방법은 전단 보강 및 전단 무보강 경우에 대하여 현행 KCI 설계기준 보다 우수한 강도 추정 능력을 가지고 있다는 점이 밝혀졌다.

Seismic behavior of reinforced concrete interior beam-column joints with beams of different depths

  • Xing, G.H.;Wu, T.;Niu, D.T.;Liu, X.
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.429-449
    • /
    • 2013
  • Current Design Codes for Reinforced Concrete (RC) interior beam-column joints are based on limited experimental studies on the seismic behavior of eccentric joints. To supplement existing information, an experimental study was conducted that focused on the effect of eccentricity of the deeper beams with respect to the shallow beams. A total of eight one-third scale interior joints with beams of different depths were subjected to reverse cyclic loading. The primary variables in the test specimens were the amount of joint transverse reinforcement and the cross section of the shallow beams. The overall performance of each test assembly was found to be unsatisfactory in terms of joint shear strength, stiffness, energy dissipation and shear deformation. The results indicated that the vertical eccentricity of spandrel beams in this type of joint led to lower capacity in joint shear strength and severe damage of concrete in the joint core. Increasing the joint shear reinforcement was not effective to alter the failure mode from joint shear failure to beam yielding which is favorable for earthquake resistance design, whereas it was effective to reduce the crack width at the small loading stages. Based on the observed behavior, the shear stress of the joint core was suggested to be kept as low as possible for a safe and practical design of this type of joint.

콘크리트 강도 및 강관 폭두께비에 따른 각형 CFT 단주의 내력평가 (Strength Evaluation of Rectangular CFT Stub Columns varing with Concrete Strength and Width-to-Thickness Ratio of Steel Tubes)

  • 심종석;한덕전
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권2호
    • /
    • pp.31-39
    • /
    • 2011
  • Concrete-filled steel tube(CFT) columns have become popular for building construction due to not only composite effect of steel tube and infilled concrete, but also more economical. The purpose of this paper is to propose the applicable boundary formula of width-to-thickness ratio for rectangular steel tube as using CFT column. A parametric study was performed taking width-to-thickness ratio of rectangular steel tube and compressive strength of concrete as the main parameter. The strength of concrete are selected to 30, 60, 90MPa. The non-linear analysis was adopted in order to take into account the effect of concrete strength. Finally, from the test and analysis results, the effect of increasing strength according to concrete strength and width-to-thickness of steel tube and plastic behavior of specimens were verified distinctly.

주상복합구조에서 전이보와 내부기둥 접합부의 반복횡하중 실험 (Cyclic Loading Test of Interior Deep-Beam Lower-Column Joint in Upper-shear Wall Lower-Frame Structure)

  • 이한선;김상연;고동우;권기혁;최성모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.446-451
    • /
    • 2000
  • In case of strong earthquake, upper-sheat wall lowe-frame structures show the weak-story failure at lower part. Where we should guarantee sufficient strength, energy dissipation capacity and ductility. In this study, a typical structure was selected for a prototype and four 1:2.5 scaled models, representing the subassemblages including the interior column and the deep beam, were constructed. Experimental parameters include transverse reinforcement ratio and axial force. The non- linear behavior of the subassemblages subjected to the cyclic lateral displac-ement were evaluated through investigation of the ultimate strength, ductility, load-deformation characteristics. From the results of the tests on 4 specimens, it is concluded that the strength increased as the axial force increased and the ductility increased as the transverse reinforcement ratio increased.

  • PDF

내부 포스트 텐션 플랫 플레이트 슬래브 기둥 접합부의 이력거동 (Cyclic Behavior of Interior Joints in Post Tensioned Flat Plate Slab Systems)

  • 기성훈;한상환;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.107-110
    • /
    • 2005
  • In general, post tensioned (PT) flat plate slab systems have been used as a Gravity Load Resisting System (GLRS) in buildings. Thus, these systems should be constructed with Lateral Force Resisting Systems (LFRS) such as shear walls and moment resisting frames. When lateral loads such as winds or earthquakes occur, lateral load resisting systems undergo displacement by which connected gravity systems experience lateral displacement. Therefore, GLRS should have some lateral displacement capacity in order to hold gravity loads under severe earthquakes and winds. Since there are the limited number of researches on PT flat plate slab systems, the behavior of the systems have not been well defined. This study investigated the cyclic behavior of post tensioned flat plate slab systems. For this purpose, an experimental test was carried out using 4 interior PT flat plate slab-column specimens. All specimens have bottom reinforcement in the slab around the slab-column connection. Test variables of this experimental study are vertical load level and tendon distribution patterns.

  • PDF

플랫 플레이트 슬래브 해석을 위한 강성감소계수 제안 (Stiffness Reduction Factor for Flat Plate Slabs)

  • 박영미;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.337-340
    • /
    • 2006
  • The purpose of this study is to propose the stiffness reduction factor for flat plate slabs under lateral loads. Current design code (e.g., ACI 318-05) requires considering the effects of cracks for calculating slab stiffness under lateral loads. This study collected the test results of 20 interior slab-column connections, from which stiffness reduction in each test was estimated with respect to the ratio of applied moment to cracking moment ($M_a/M_{cr}$). Based on collected data, this study proposed equations for calculating stiffness reduction with respect to $M_a/M_{cr}$. To verify the proposed equations, this study conducted the experimental test of interior slab-column connections under quasi-static cyclic loading. From the test, load-deformation curve is compared to that obtained from effective beam width method with the proposed equation for the stiffness reduction. It is shown that the effective beam width method with the proposed equation for stiffness reduction predicts accurately the test results.

  • PDF

Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings

  • Kwon, Kwangho;Park, Seromi;Kim, Jinkoo
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.229-235
    • /
    • 2012
  • In this paper the progressive collapse potential of building structures designed for real construction projects were evaluated based on arbitrary column removal scenario using various alternate path methods specified in the GSA guidelines. The analysis model structures are a 22-story reinforced concrete moment frames with core wall building and a 44-story interior concrete core and exterior steel diagrid structure. The progressive collapse resisting capacities of the model structures were evaluated using the linear static, nonlinear static, and nonlinear dynamic analyses. The linear static analysis results showed that progressive collapse occurred in the 22-story model structure when an interior column was removed. However the structure turned out to be safe according to the nonlinear static and dynamic analyses. Similar results were observed in the 44-story diagrid structure. Based on the analysis results, it was concluded that, compared with nonlinear analysis procedures, the linear static method is conservative in the prediction of progressive collapse resisting capacity of building structure based on arbitrary column removal scenario.