• 제목/요약/키워드: interfacial bond

Search Result 188, Processing Time 0.023 seconds

Effect of intracanal medications on the interfacial properties of reparative cements

  • Pereira, Andrea Cardoso;Pallone, Mariana Valerio;Marciano, Marina Angelica;Cortellazzi, Karine Laura;Frozoni, Marcos;Gomes, Brenda P.F.A.;de Almeida, Jose Flavio Affonso;de Jesus Soares, Adriana
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.21.1-21.8
    • /
    • 2019
  • Objectives: The purpose of the present study was to evaluate the effect of calcium hydroxide with 2% chlorhexidine gel (HCX) or distilled water (HCA) compared to triple antibiotic paste (TAP) on push-out bond strength and the cement/dentin interface in canals sealed with White MTA Angelus (WMTA) or Biodentine (BD). Materials and Methods: A total of 70 extracted human lower premolars were endodontically prepared and randomly divided into 4 groups according to the intracanal medication, as follows: group 1, HCX; group 2, TAP; group 3, HCA; and group 4, control (without intracanal medication). After 7 days, the medications were removed and the cervical third of the specimens was sectioned into five 1-mm sections. The sections were then sealed with WMTA or BD as a reparative material. After 7 days in 100% humidity, a push-out bond strength test was performed. Elemental analysis was performed at the interface, using energy-dispersive spectroscopy. The data were statistically analyzed using analysis of variance and the Tukey test (p < 0.05). Results: BD presented a higher bond strength than WMTA (p < 0.05). BD or WMTA in canals treated with calcium hydroxide intracanal medications had the highest bond strength values, with a statistically significant difference compared to TAP in the WMTA group (p < 0.05). There were small amounts of phosphorus in samples exposed to triple antibiotic paste, regardless of the coronal sealing. Conclusions: The use of intracanal medications did not affect the bond strength of WMTA and BD, except when TAP was used with WMTA.

Effects of Interfacial Dielectric Layers on the Electrical Performance of Top-Gate In-Ga-Zn-Oxide Thin-Film Transistors

  • Cheong, Woo-Seok;Lee, Jeong-Min;Lee, Jong-Ho;KoPark, Sang-Hee;Yoon, Sung-Min;Byun, Chun-Won;Yang, Shin-Hyuk;Chung, Sung-Mook;Cho, Kyoung-Ik;Hwang, Chi-Sun
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.660-666
    • /
    • 2009
  • We investigate the effects of interfacial dielectric layers (IDLs) on the electrical properties of top-gate In-Ga-Zn-oxide (IGZO) thin film transistors (TFTs) fabricated at low temperatures below $200^{\circ}C$, using a target composition of In:Ga:Zn = 2:1:2 (atomic ratio). Using four types of TFT structures combined with such dielectric materials as $Si_3N_4$ and $Al_2O_3$, the electrical properties are analyzed. After post-annealing at $200^{\circ}C$ for 1 hour in an $O_2$ ambient, the sub-threshold swing is improved in all TFT types, which indicates a reduction of the interfacial trap sites. During negative-bias stress tests on TFTs with a $Si_3N_4$ IDL, the degradation sources are closely related to unstable bond states, such as Si-based broken bonds and hydrogen-based bonds. From constant-current stress tests of $I_d$ = 3 ${\mu}A$, an IGZO-TFT with heat-treated $Si_3N_4$ IDL shows a good stability performance, which is attributed to the compensation effect of the original charge-injection and electron-trapping behavior.

Performance evaluation of soil-embedded plastic optical fiber sensors for geotechnical monitoring

  • Zhang, Cheng-Cheng;Zhu, Hong-Hu;Shi, Bin;She, Jun-Kuan;Zhang, Dan
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.297-311
    • /
    • 2016
  • Based on the distributed fiber optic sensing (DFOS) technique, plastic optical fibers (POFs) are attractive candidates to measure deformations of geotechnical structures because they can withstand large strains before rupture. Understanding the mechanical interaction between an embedded POF and the surrounding soil or rock is a necessary step towards establishing an effective POF-based sensing system for geotechnical monitoring. This paper describes a first attempt to evaluate the feasibility of POF-based soil deformation monitoring considering the POF-soil interfacial properties. A series of pullout tests were performed under various confining pressures (CPs) on a jacketed polymethyl methacrylate (PMMA) POF embedded in soil specimens. The test results were interpreted using a fiber-soil interaction model, and were compared with previous test data of silica optical fibers (SOFs). The results showed that the range of CP in this study did not induce plastic deformation of the POF; therefore, the POF-soil and the SOF-soil interfaces had similar behavior. CP was found to play an important role in controlling the fiber-soil interfacial bond and the fiber measurement range. Moreover, an expression was formulated to determine whether a POF would undergo plastic deformation when measuring soil deformation. The plasticity of POF may influence the reliability of measurements, especially for monitored geo-structures whose deformation would alternately increase and decrease. Taken together, these results indicate that in terms of the interfacial parameters studied here the POF is feasible for monitoring soil deformation as long as the plastic deformation issue is carefully addressed.

Shear Bond Strength and Interfacial Characterization of Ceramic to Beryllium Free Nonprecious Alloys for Porcelain Fused to Metal Crown (베릴륨이 포함되지 않은 도재용착용 비귀금속 합금과 세라믹간의 전단결합강도와 계면특성)

  • Chung, In-Sung;Kim, Chi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.11
    • /
    • pp.228-234
    • /
    • 2010
  • Ni-Cr and Co-Cr alloy uncontained Be element for using as dental porcelain alloy were analyzed the mechanical properties through bonding strength and fracture test after the bonding with porcelain. The bonding strengths between alloy and ceramic were measured through the shear bond strength test. Consequently, the T-3 group contained Be element that had shear strength of 41.13(${\pm}5.11$)MPa was showed the highest shear strength than the other groups. The second highest group was a verabond contained Be element that had shear strength of 40.72(${\pm}5.98$)MPa. The results of the other groups according to the shear strength were Wirobond(38.40(${\pm}9.66$)MPa) belonged to Co-Cr alloy, and Verabond 2V(32.77(${\pm}4.31$)MPa), Bellabond N(28.63(${\pm}6.39$)MPa), Bellabond plus(24.97(${\pm}6.13$)MPa), Argeloy N.P. Star(22.69(${\pm}3.41$)MPa) uncontained Be element, respectively. The morphological aspects of the fracture surface between alloys and ceramic were observed that all groups were caused mixed failure as conformation attached ceramic fragments to metallic surface by fracture process.

SHEAR BOND STRENGTH OF REPAIRED COMPOSITE RESIN RESTORATIONS (수리된 복합레진 수복물의 전단결합강도 연구)

  • Choi, Soo-young;Jeong, Sun-Wa;Hwang, Yun-Chan;Kim, Sun-Ho;Yun, Chang;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.569-576
    • /
    • 2002
  • This study was peformed to evaluate the interfacial shear bond strength of base (direct and indirect) and repair composites with aging and surface treatment methods. Direct composite resin specimens ($Charisma^{\circledR}$, Heraeus Kulzer, Germany) were aged for 5 min, 1 hour, 24 hours, and 1 week in $37^{\circ}C$ distilled water before surface treatment, and then divided into five groups Group 1, grinding; Group 2, grinding and application of bonding agent, Group 3, grinding, etching with 37% phosphoric acid for 30sec, and application of bonding agent, Group 4, grinding, etching with 37% phosphoric acid for 30sec, silane treatment, and application of bonding agent ; Group 5, grinding, etching with 4% hydrofluoric acid for 30sec. silane treatment, and application of bonding agent. Indirect composite resin specimens ($Artglass^{\circledR}$, Heraeus Kulzer, Germany) were aged for 1 week in $37^{\circ}C$ distilled water and divided into seven groups Group 1 - Group 5, equal to Charisma specimens; Group 6, grinding, etching with 37% phosphoric acid for 60sec, silane treatment, and application of bonding agent; Group7, grinding, etching with 4% hydrofluoric acid for 60 sec, silane treatment, and application of bond-ing agent. The repair material($Charisma^{\circledR}$) was then added on the center of the surface (5 mm in diameter. 5 mm in height). The shear bond strength was tested and the data was analyzed using one-way ANOVA and the Student- Newman-Keuls test. The following conclusions were drawn. 1 The shear bond strength of $Charisma^{\circledR}$ specimens aged for 1 hour was significantly higher in Group 2 and Group 5 than in Group 1 (p<0.05), and that of $Charisma^{\circledR}$ specimens aged for 1 week was signifi-cantly higher in Group 3 and Group 5 than in Group 1 (p<0.05). No significant difference was found in the bond strength of specimens aged for 5 min and 24 hours. 2. In Group 2 of the $Charisma^{\circledR}$ specimens, there was significant difference between the bond strength of 24 hours and that of 1 week (p<0.05). 3. In Group 4 of the $Charisma^{\circledR}$ specimens, the shear bond strength of specimens aged for 24 hours was significantly higher than the others(p<0.05) 4. There was no significant difference between the shear bond strength of the $Artglass^{\circledR}$ specimens, 5. Most of the $Charisma^{\circledR}$ specimens showed cohesive fractures. Artglass^{\circledR}$ specimens that were etched with acid (phosphoric or hydrofluoric) for 30 sec showed more cohesive fractures.

A FEA Study on the Bond Property according to the Rib-Shape of Reinforcement (철근 마디형상에 따른 부착특성에 관한 해석적 연구)

  • Mihn, Joon-Soo;Hong, Geon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.38-46
    • /
    • 2014
  • Effects of various parameters on bond property between reinforcing bar and concrete are investigated in many researchers, and various study is on going to improve the bond strength. Properties of interface between reinforcement and concrete is important role in bond property. This study analyzed the interfacial bond mechanism between deformed bar and concrete by finite element analysis (FEA) to evaluate the effect of rib shape. The FEA model in this study is simplified 2D plane stress model. The variables of analysis are selected by rib angle, rib height, rib spacing and relative rib area. From the results of analysis, reinforcing bars with rib angle $30{\sim}60^{\circ}$ showed better bond strength than the others. Bond strength ratio following to the rib height is proportionally increased up to the $0.12d_b$, but rib spacing has little effect on bond strength. The results also indicated that relative rib area can be efficiently represented the properties of deformed shape in reinforcing bars, and zigzagged rib height shape showed excellent bond strength increase.

THE STUDY ON SHEAR BOND STRENGTHS OF VARIOUS ONE-BOTTLE DENTIN ADHESIVES (수종의 One-bottle 상아질 결합제의 전단 결합 강도에 관한 연구)

  • Oh, So-Hee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.553-565
    • /
    • 2001
  • One-bottle adhesive system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. To test the shear bond strength of a new "one-bottle adhesive" system to bovine dentin various commercially available one-bottle adhesives(Prime & Bond $2.1^{(R)}$, One Coat $Bond^{(R)}$, Syntac $Sprint^{(R)}$, Single $Bond^{(R)}$) were included for comparison. And we observe the interfacial morphology by scanning electron microscope. The results were as follows; 1. Group II (One Coat $Bond^{(R)}$) showed higher shear bond strength than group I (Prime & Bond $2.1^{(R)}$), group III(Syntac $Sprint^{(R)}$), and group IV(Single $Bond^{(R)}$), but no statistically significant difference was founded between groups(p>.05). 2. Relating reverse-cone shape resin tags were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other three groups, and discontinuous hybrid layer.

  • PDF

Effect of Surface Treatments of Titanium on Bond Strength and Interfacial Characterization in Titanium-Ceramic Prosthesis (티타늄의 표면처리방법에 따른 티타늄-세라믹 보철시편의 결합강도와 계면특성)

  • Chung, In-Sung;Kim, Chi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.10
    • /
    • pp.219-225
    • /
    • 2010
  • The bonding strength between titanium and ceramic were analyzed according to the bonding agent and the coating methods of Au and TiN respectively. The bonding strength was measured through the 3 point bending test. Consequently, the bonding strength of the special bonding agent after the TiN coated (SPTB) group was $72.20({\pm}5.25)MPa$ which was the strongest one among groups. The bonding strength of the special bonding agent treated only (SPB) group was $67.66({\pm}12.10)MPa$, the special bonding agent after the Au coating SPGB group was $46.95({\pm}12.48)MPa$ and the SP group was $43.80({\pm}5.12)MPa$. Taking these results into account, the bonding strength of the SPB group shows the same as it of the SPTB group, however, it is stronger than SP group. And the TiN coated SPTB group shows the stronger bonding strength than the Au coated SPGB group.

Molecular Orbital Study of Binding at the Pt(111)/${\gamma}-Al_2O_3$(111) Interface (Pt(111)/${\gamma}-Al_2O_3$(111) 계면간 결합에 관한 분자 궤도론적 연구)

  • Choe, Sang Joon;Park, Sang Moon;Park, Dong Ho;Huh, Do Sung
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.4
    • /
    • pp.264-272
    • /
    • 1996
  • Cluster models of the Υ-Al2O3(111) and the Pt(111) surfaces have been used in an atom superposition and electron delocalization molecular orbital study of interfacial bond strengths between them. The reduced extents for Al3+ are due to the ratio of oxygen to aluminum atoms. The greater the reduced extent for Al3+ is, the stronger the binding energy is to Pt atoms in a cluster. The oxygen-covered surfaces of Υ-Al2O3(111) are shown to bind more weakly to Pt atoms, while the binding to the oxygen-covered surface formed under oxidizing conditions of Pt atoms is strong. The interfacial bond of platinum-alumina may be possible by a charge-transfer mechanism from the platinum surface to the partially empty O-2p band and Al3+ dangling surface orbital.

  • PDF

Experimental Study on the Flexural Behavior Effect of RC Beam Repaired and Strengthened by Latex Modified Concrete (라텍스개질콘크리트로 보수·보강된 RC 보의 휨 거동에 관한 실험적 연구)

  • Kim, Seong-Hwan;Yun, Kyong-Ku;Kim, Yong-Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.503-510
    • /
    • 2009
  • Latex modified concrete (LMC) is a successful polymer-portland cement concretes, which have been developed and used for many years, in overlaying bridge decks and resurfacing industrial floors. The excellent bond strength to substrate, easy application and high resistance to impact, abrasion, wear, aggressive chemicals and freeze-thaw deterioration have made this material used widely. The objective of this study was to determine experimentally the load-deflection response and ultimate strength of reinforced RC beams. The cracking patterns and the mode of failure were observed. Because of excellent bond strength and repairing effects, the RC beams repaired by LMC at compression or tension zone showed over 100% recovery from damaged structures. The RC beams overlaid by LMC showed significant improvement at load carrying capacity as overlay thickness increases. However, the beams repaired of tension zone without shear stirrups almost showed no strengthen effect, and indicated an interfacial failures. The interfacial behavior was estimated by numerical method adopting the concept of shear flow.