• 제목/요약/키워드: interface pressure

검색결과 1,047건 처리시간 0.026초

LPG/CNG Interface Box 제품 Hardware 설계 (LPG/CNG Interface Box Hardware Design)

  • 안정훈;정재민
    • 한국자동차공학회논문집
    • /
    • 제15권6호
    • /
    • pp.23-29
    • /
    • 2007
  • In Korea, the number of LPG vehicles is increasing continuously because LPG is cheaper than Gasoline. Also in Europe, the CNG fuel is a good solution to meet $CO_2$ regulation. In order to use LPG/CNG fuel, new EMS ECU must be developed for every type of vehicles and it requires huge development cost. In order to reduce development cost and time, SIEMENS VDO has developed an Interface Box. It supports EMS ECU in the car and manages LPG/CNG fuel injection system. Basically the Interface box can be used with any kind of EMS ECU. The Interface Box controls LPG/CNG injector through the injection command of gasoline EMS ECU. It calculates required amount of based on the fuel temperature and pressure and sends feedback signal to ECU for fuel correction. Also, it controls LPG/CNG specific actuator such a Shut off valves and LPG switch inputs.

강-콘크리트 계면의 계면상수 결정 : 계면상수의 역학적 성질 (Determination of Steel-concrete Interface Parameters: Me chanical Properties of Interface Parameters)

  • 이타;주영태;이용학
    • 콘크리트학회논문집
    • /
    • 제21권6호
    • /
    • pp.781-788
    • /
    • 2009
  • 강-콘크리트 계면의 성질을 대표하는 부착강도, 부착 및 비부착 마찰계수, 부착 및 비부착 마찰계수의 연화영역에서 잔류량의 크기, 모드 I 파괴에너지, 부착 및 비부착 모드 II 파괴에너지, 파괴포락선의 형상계수를 포함한 총 9개 계면상수의 값을 계면거동실험결과와 파괴포락선의 기하학적 형상 및 구성모델을 이용하는 민감도 해석을 통해 결정하였다. 계면의 거동이 계면의 부착상태뿐만 아니라 계면법선방향 응력의 방향과 크기에 따라 매우 민감하게 작용하므로 계면상수 값의 결정에서는 이러한 구속압의 크기와 부착 및 비부착 계면조건을 고려하였다. 강재판 사이에 콘크리트가 타설된 강-콘크리트 계면실험체의 거동해석을 위한 계면유한요소해석을 결정된 계면상수를 적용하여 수행하였으며 실험결과와의 비교를 통해 상수값의 적정성을 검토하였다.

복합재 고압용기의 스마트 모니터링을 위한 FBG 센서의 삽입 적용성에 관한 연구 (Feasibility Study of Embedded FBG Sensors for the Smart Monitoring of High Pressure Composite Vessel)

  • 박상욱;박상오;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.33-36
    • /
    • 2005
  • In this research, for the smart health monitoring of the hydrogen storage high pressure composite vessel, the feasibility study of an embedded fiber Bragg grating(FBG) sensor is carried out. To verify strain measurement in various temperature environment which is needed for the hydrogen pressure vessel, tensile test of a composite specimen with both an embedded FBG sensor and a strain gauge is made in low temperature. Before we try a real-size hydrogen storage pressure vessel, a small & cheap composite pressure vessel having the same structure is fabricated with embedded FBG sensors and tested. In the case of an aluminum liner inside the vessel, survivability of FBG sensors at the interface is lower than the other areas.

  • PDF

감각귀환형 기능적 전기자극 시스템(SEFES)을 위한 발압력 분포 계측시스템의 개발 (Development of Measurement Systems of Foot Pressure Distribution for Sensory-Feedback type FES System(SEFES))

  • 김주명;김양영;양경모;고수복;정동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.88-91
    • /
    • 1994
  • We develope a assistant system of foot pressure distribution for improvement gait Pattern, adapted working speed, and minimitation of muscle fatigue of the sensory feedback type FES system(SEFES). This measurement system consist of mat type pressure sensor with piezo electric films. The pressure data signal multiflexed input scanning method processed A/D conversion after two step amplify and integrate. Matrix sensor interface to PC for pseudo color display by level of Pressure distribution data. This measurement system clinically evaluated in hemiplegic patients. It has produced acceptable results with optimal location of the food sensor's pressure point and avoid the muscle fatigue.

  • PDF

흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포 (Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket)

  • 장윤희;김영호;양길태;임송학;문무성
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.249-252
    • /
    • 1997
  • A study on static and dynamic socket pressure distributions on a trans-femoral amputee with a suction socket was performed in order to assess an optimal socket fitting and function. Even for the amputee's static neutral position, pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free walking, a significant movement of pressure concentration areas was observed. Large socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

흙의 동상민감성과 포화도를 고려한 동상팽창압 특성 (Frost Heaving Pressure Characteristics of Frozen soils with Frost-Susceptibility and Degree of Saturation)

  • 신은철;박정준;김종인
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.329-336
    • /
    • 2002
  • The earth structures and in-ground LNG tank, and buildings can be constructed with using artificial freezing method on the reclaimed land. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. The pressure is the result of the surface energy of a curved ice-water interface. The most significant of these parameters will have the greatest effect on the classification. In order to establish frost-susceptibility criteria based on frost heaving expansion pressure, more soils have to be tested. This study was initiated to investigate the soils frost heaving expansion pressure and moisture characteristics resulting from freezing and freezing-thawing cycle process. Weathered granite soils, sandy soil, sandy soil were used in the laboratory freezing test subjected to thermal gradients under closed- systems.

  • PDF

환경에 따른 MZT/LZT 디스크의 tribological 특성 (Tribological Behavior of MZ/LZT disk under Various Environmental Conditions)

  • 박용식;김대은
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.53-60
    • /
    • 1999
  • As the flying height decreased, it is essential that hard disk drives perform reliable under various environmental conditions. In this paper the tribological characteristics of a head/disk interface are investigated under various temperature, relative humidity, altitude and outgas conditions. Specially, Contact-Start-Stop(CSS) tests were performed to assess the stiction, acoustic emission, slider take-off behavior, and track average amplitude(TAA). It is shown that the surface damage and head failure are accelerated by high temperature and humidity as well as low ambient pressure.

  • PDF

XLPE/EPDM의 계면처리조건에 따른 절연파괴 특성 (Breakdown Characteritics of XLPE/EPDM on the Treatment Condition of the Interfacial layer)

  • 한성구;조정형;이창종;박양범;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1996
  • In this paper, We intended to evaluate characteristics of XLPE/EPDM interface which exists in the cable joint. Because the fault was mainly occurred in this interface. We investigated breakdown characteristics of XLPE/EPDM double layered insulator as a funtion of temperature, pressure, annealing time, kinds of jointmaterial. It was shown that breakdown strength of XLPE/EPDM insulators is higher that of XLPE/XLPE or EPDM/EPDM

  • PDF

Numerical analysis for supercavitating flows around axisymmetric cavitators

  • Kwack, Young Kyun;Ko, Sung Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권3호
    • /
    • pp.325-332
    • /
    • 2013
  • Diffuse interface model for numerical analysis was used to compute supercavitating flows around various cavitators. The ambient pressures of 2 atm permitted cavitation studies in a range of cavitation number, ${\sigma}=0.1$ to 1.0 on selected conical and disk-headed cavitors. The computed results were compared with relation by Reichardt. Drag coefficient obtained from pressure forces acting on the cavitator also compared well with those obtained from analytical relations.

Low Temperature Cure Film Adhesive

  • Liang, Bin;Zhao, Shenglong
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2004
  • A novel carboxyl terminated butadiene-acrylonitrile (CTBN) modified, low temperature cure epoxy film adhesive was developed in this paper. It can be cured at as low as $75^{\circ}C$ for 4 hours with a pressure of 0.1MPa. After post cure at $120^{\circ}C$ for 2 hours, the bonding strengths of Phosphoric Acid Anodizing(PAA) surface treated aluminum adherend were similar to those of structural film adhesives curing at $120^{\circ}C$. It is suitable to bond both metal/composite laminate-to-laminate and laminate to honeycomb structure.

  • PDF