• Title/Summary/Keyword: interface efficiency

Search Result 1,109, Processing Time 0.465 seconds

CAD/CAPP System based on Manufacturing Feature Recognition (제조특징인식에 의한 CAD/CAPP 시스템)

  • Cho, Kyu-Kab;Kim, Suk-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.1
    • /
    • pp.105-115
    • /
    • 1991
  • This paper describes an integrated CAD and CAPP system for prismatic parts of injection mold which generates a complete process plan automatically from CAD data of a part without human intervention. This system employs Auto CAD as a CAD model and GS-CAPP as an automatic process planning system for injection mold. The proposed CAD/CAPP system consists of three modules such as CAD data conversion module, manufacturing feature recognition module, and CAD/CAPP interface module. CAD data conversion module transforms design data of AutoCAD into three dimensional part data. Manufacturing feature recognition module extracts specific manufacturing features of a part using feature recognition rule base. Each feature can be recognized by combining geometry, position and size of the feature. CAD/CAPP interface module links manufacturing feature codes and other head data to automatic process planning system. The CAD/CAPP system can improve the efficiency of process planning activities and reduce the time required for process planning. This system can provide a basis for the development of part feature based design by analyzing manufacturing features.

  • PDF

Development of Freeze Drying Analysis Program using Fixed Grid (고정격자를 이용한 동결건조 해석프로그램의 개발)

  • Nam Jin Hyun;Song Chi Sung;Kim Charn-Jung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.923-931
    • /
    • 2004
  • A multi-dimensional freeze drying analysis program, which took simultaneous heat and mass transfer, sublimation of ice and motion of sublimation front into full account, was developed using finite volume method with fixed grid. The effect due to the motion of sublimation interface was modeled by an enthalpy formulation streamlined for the freeze drying problems. The efficiency and accuracy of the program was validated by solving one- and two-dimensional freeze drying problems frequently encountered in industrial processes. Finally, the freeze drying processes of cylinder and slab objects with permeable side surfaces were simulated, which demonstrated the capability of the present analysis program in solving multi-dimensional freeze drying problems with complex sublimation interface configurations.

Design of Reconfigurable Desk Based on Pin Art Technology (핀 아트 기술을 활용한 재구성 가능한 데스크 설계)

  • Jeong, Seungdo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.2
    • /
    • pp.63-70
    • /
    • 2019
  • To increase the efficiency of task on the desk, this paper proposes a reconfigurable desk. The proposed reconfigurable desk is based on the Pin Art technology. For the design of the proposed desk, the upper surface of the desk is divided into small units, and then the user easily controls the height of the divided pieces to make desk a desired shape by using the proposed user interface. The Arduino module controls the hardware and the user interface is configured by using Android applications, making it easy for anyone to use. Through extensive experiments, the proposed system shows that various types of deformations are possible and thus the utilization is very high by mounting diverse devices.

WEB-BASED SERVICE REQUEST & FEEDBCK SYSTEM: THE LIFE CYCLE MANAGEMENT AS CONTINUOUS CUSTOMIZATION OF FACILITY INFORMATION

  • Jinsu Jeong;Kwang Jun Lee;Valerian Miranda
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.836-840
    • /
    • 2005
  • This research investigates the feasibility of Web technology as a means of delivering facility information for better support facility operation and maintenance. Our research proposes a Web-based feedback system as a pragmatic solution to the limitations of current FM (Facility Management) processes. In practice work orders and records are often misplaced resulting in lower efficiency and customer satisfaction. This may be overcome by a system that states information digitally and provides a Web-based interface. The interface could allow customers to report facility problems, trace their work order in progress, view schedules for maintenance and provide feedback for service online. The benefit for a FM department is that it can receive feedback on performance which would improve the quality of service and build a record of practical experiences.

  • PDF

A Study on Automatic Generation of Interface Circuits Based on FSM between Standard Buses and Ips (FSM을 이용한 표준화된 버스와 IP간의 인터페이스 회로 자동생성에 관한 연구)

  • Lee, Ser-Hoon;Moon, Jong-Uk;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2A
    • /
    • pp.137-146
    • /
    • 2005
  • IP-based design methodology has been popularly employed for SoC design to reduce design complexity and to cope with time-to-market pressure. Interface modules for communication between system buses and IPs are required, since many IPs employ different protocols. Automatic generation of these interface modules would enhance designer's productivity and IP's reusability. This paper proposes an automatic interface generation system based on FSM generated from the protocol description of IPs. The proposed system provides the library modules for the standard buses to reduce the burdens of describing the protocols for data transfer from/to standard buses. Experimental results show that the area of the interface circuits generated by the proposed system had been increased slightly by 4.5% on the average when compared to manual designs. In the experiment, where bus clock is 100 Mhz and slave module clock is 34 Mhz, the latency of the interface had been increased by 7.1% in burst mode to transfer 16 data words. However, occupation of system bus can be reduce by 64.9%. A chip designer can generate an interface that improves the efficiency of system bus, by using this system.

A Study of a Virtual Reality Interface of Person Search in Multimedia Database for the US Defense Industry (미국 방위산업체 상황실의 인물검색 활동을 돕는 가상현실 공간 인터페이스 환경에 관한 연구)

  • Kim, Na-Young;Lee, Chong-Ho
    • Journal of Korea Game Society
    • /
    • v.11 no.5
    • /
    • pp.67-78
    • /
    • 2011
  • This paper introduces an efficient and satisfactory search interface that enables users to browse and find the video data they want from a massively huge video database widely used in various multimedia environment. The target user group is information analysts at US defense industry or governmental intelligence agencies whose job is to identify a certain person from a lot of video footage taken from CCTV(Closed-circuit Television) cameras. For the first user test, we suggested the CAVE-like virtual reality interface to be the most optimal for the tasks we designed for, so we compared this interface with desktop interface. The softwares and database developed and optimized for each task were used in this user test. For the second user test, we researched on what input devices would be most optimal for enhancing efficiency of search task in the CAVE-like virtual reality system. Especially we focused our effort on measuring the effectiveness and user satisfaction of three different types of devices that embody gestural interface input system that encourages users' ergonomic control of the interface. We also measured the time consumed for performing each task to find out the most efficient input device among the ones tested.

Effects of Immobilized Bipolar Interface Formed by Multivalent and Large Molecular Ions on Electrodialytic Water Splitting at Cation-Exchange Membrane Surface (양이온교환막 표면의 전기투석 물분해에서 다가의 큰 이온성분자에 의해 형성된 고정층 바이폴라 계면의 영향)

  • Seung-Hyeon Moon;Moon-Sung Kang;Yong-Jin Choi
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.143-153
    • /
    • 2003
  • The effects of bipolar interface formed on the surface of cation-exchange membrane on water splitting phenomena were investigated. Results showed that the formation of immobilized bipolar interface resulted in significant water splitting during electrodialysis. In particular, the immobilized bipolar interface was easily created on the cation-exchange membrane surface in the electrodialytic systems where multivalent cations served as an electrolyte. Multivalent cations with low solubility product resulted in violent water splitting because they were easily precipitated on the membrane surface in hydroxide form. Therefore, the bipolar interface consisting of H- and OH-affinity groups were formed on the membrane-solution interface. Apparently, water splitting was largely activated with the help of strong electric fields generated between the metal hydroxide layer and fixed charge groups on the membrane surface. Likewise, the accumulation of large molecular counter ions on the membrane surface led to the formation of a fixed bipolar structure that could cause significant water splitting in the over-limiting current region. Therefore, the prevention of the immobilization of bipolar interface on the membrane surface is very essential in improving the process efficiency in a high-current operation.

Highly Stabilized Protocrystalline Silicon Multilayer Solar Cells (고 안정화 프로터결정 실리콘 다층막 태양전지)

  • Lim Koeng Su;Kwak Joong Hwan;Kwon Seong Won;Myong Seung Yeop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.102-108
    • /
    • 2005
  • We have developed highly stabilized (p-i-n)-type protocrystalline silicon (pc-Si:H) multilayer solar cells. To achieve a high conversion efficiency, we applied a double-layer p-type amorphous silicon-carbon alloy $(p-a-Si_{1-x}C_x:H)$ structure to the pc-Si:H multilayer solar cells. The less pronounced initial short wavelength quantum efficiency variation as a function of bias voltage proves that the double $(p-a-Si_{1-x}C_x:H)$ layer structure successfully reduces recombination at the p/i interface. It was found that a natural hydrogen treatment involving an etch of the defective undiluted p-a-SiC:H window layer before the hydrogen-diluted p-a-SiC:H buffer layer deposition and an improvement of the order in the window layer. Thus, we achieved a highly stabilized efficiency of $9.0\%$ without any back reflector.

  • PDF

An experimental performance analysis of a cold region stationary photovoltaic system

  • Choi, Wongyu;Warren, Ryan D.;Pate, Michael B.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.1-28
    • /
    • 2016
  • A grid-connected photovoltaic (PV) system comprised of multicrystalline silicon (mc-Si) modules was installed in a cold climate region in the U.S. This roof-mounted stationary PV system is a real-world application of PV for building energy generation in International Energy Conservation Code (IECC) Climate Zone 5 (and possibly similar climate zones such as 6, 7 and 8), and it served the purposes of research, demonstration, and education. The importance of this work is highlighted by the fact that there has been less emphasis on solar PV system in this region of the U.S. because of climate and latitude challenges. The system is equipped with an extensive data acquisition system capable of collecting performance and meteorological data while visually displaying real-time and historical data through an interactive online interface. Experimental data was collected and analyzed for the system over a one-year period with the focus of the study being on measurements of power production, energy generation, and efficiency. The annual average daily solar insolation incident upon the array was found to be $4.37kWh/m^2$. During the first year of operation, the PV system provided 5,801 kWh (1,264 kWh/kWp) of usable AC electrical energy, and it was found to operate at an annual average conversion efficiency and PR of 10.6 percent and 0.79, respectively. The annual average DC to AC conversion efficiency of the inverter was found to be 94 percent.

Efficiency Improvement of Green Emitting OLED by Aquaregia Treatment of ITO Substrate (ITO 기판의 Aquaregia 처리에 의한 녹색발광 OLED의 효율 향상 연구)

  • Choi, Gyu-Chae;Kim, Dong-Eun;Kim, Byoung-Sang;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1291-1292
    • /
    • 2008
  • ITO is widely used as an anode material in OLED, because of its good transparency, low electrical resistivity, high work function, and efficient hole injection properties. The interface between the electrode and the organic layer in the OLED effects the charge injection process and may influence the electrical and the luminance properties. Surface treatment of ITO, such as an Aquaregia treatment has been shown to enhance the efficiency, and luminance characteristics of the OLED. In this study, we investigated the effect of Aquaregia treatment. The fundamental structures of the OLED were ITO/NPB/$Alq_3$/LiF/Al. The current density-voltage-luminance, efficiency, and lifetime characteristics were measured with untreated and Aquaregia-treated ITO substrates. The Aquaregia treatment was found to enhance the performance of OLED. For the Aquaregia treated device, the maximum luminance and efficiency were increased by about 2 times compared to the untreated device. The mechanism of the Aquaregia treatment is discussed based on AFM analyses.

  • PDF