• 제목/요약/키워드: interconnected system

검색결과 602건 처리시간 0.035초

연계계통에서 안전도제약을 고려한 최적전력조류 (Optimal Power Flow considering Security in Interconnected Power Systems)

  • 김규호;이재규;이상봉;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.194-196
    • /
    • 2001
  • This paper presents a hybrid algorithm for solving security constrained OPF in interconnected power systems, which is based on the combined application of evolutionary programming (EP) and sequential quadratic programming (SQP). The objective functions are the minimization of generation fuel costs and system power losses. In OPF considering security, the outages are selected by contingency ranking method. The control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SVC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow. The method proposed is applied to the modified IEEE 14buses model system.

  • PDF

남북한 연계선로 평가 및 최적안 선정에 관한 연구 (A Study on Evaluation of Tie Lines between North and South Korea and its Selection of the Best Alternative)

  • 차준민;노대석;최재석;김홍래;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.414-417
    • /
    • 2001
  • This paper presents the results of power flow of North-South Korea system with interconnected cases which were proposed by various present studies PSS/E and PowerWorld Simulator were used to analyze the inter connected system with several interconnected lines alternatives. The results would be very useful to select the best alternative for interconnection with considering several evaluation terms.

  • PDF

PSCAD/EMTDC를 이용한 전지전력저장시스템의 수리모형에 관한 연구 (A Study on Mathematical Modeling of Battery Energy Storage Systems using PSCAD/EMIDC)

  • 김용상;김재언;노대석;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1035-1037
    • /
    • 1997
  • This paper deals with the mathematical modeling of battery energy storage systems interconnected with the distribution system. This battery model takes account of self-discharge, battery storage capacity, internal resistance and overvoltage. The model components are decided by using an approximation technique and experimental results. This model can be used to evaluate battery performance of battery energy storage systems interconnected with distribution system.

  • PDF

분산형 전원이 연계된 배전계통에 분산형 전원 추가 시 리크로저와 섹셔널아이저의 보호 협조 방안 (The effective recloser and sectionalizer coordination and protection scheme when distributed resource is added in distribution system interconnected distributed resource)

  • 정현준;최준호;남해곤;박성준;박장현;노경수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.704-706
    • /
    • 2005
  • According to the second scheme of the Korean Government about technology development, utilization and popularization of new ${\cdot}$ renewable energy, the continuous growth of distributed resources are expected. But there is a few paper about recloser and sectionalizer coordination and protection scheme in distribution system interconnected a number of distributed resources. In this paper, it is dealt with that recloser and sectionalizer coordination at the cases concerned with position among protection devices. Adding distributed resource, the problems of each case are investigated through simulation.

  • PDF

다수 연결된 전력계통에 대한 최적 다가변 구조 제어기 (Optimal Multidimensional Variable Structure Controller for Multi-Interconnected Power Systems)

  • Lee, Ju-Jang
    • 대한전기학회논문지
    • /
    • 제38권9호
    • /
    • pp.671-683
    • /
    • 1989
  • A controller of interconnected power systems is investigated using an optimal multidimensional variable structure control. The switching hyperplane of the variable structure stabilizer is obtained by minimizing a quadratic performance index in continuous-time. A special feature of the optimal multidimensional variable structure stabilizer is that, when it is operated in the so-called sliding mode, the system response becomes insensitive to changes in the plant parameters. A digital simulation is performed by a digital computer using the Advanced Continuous Simulation Language (ACSL) package, which shows that the dynamic performance of the power system in response to mechanical torque changes is improved when optimal multidimensional variable sturcture stabilizers are employed.

  • PDF

시간지연을 갖는 불확정성 대규모 시스템의 강인 제어기 설계 (Design of Robust Controller for Uncertain Large-scale Systems with Time-delays)

  • 이희송;김진훈
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권1호
    • /
    • pp.26-32
    • /
    • 2000
  • In this paper, we consider to robust controller design problem for the linear large scale systems with the uncertainties and the time-delays. The considered time-delays are that exist in the state and the input of the subsystems and the interconnected subsystems. And the considered uncertainties are two general types that exist in the system, input and interconnected matrices. Based on the linear matrix inequality(LMI) and Lyapunov theorem, we present sufficient conditions for the existence of a controller that guarantees the asymptotic stability of systems regardless of the uncertainties and the time-delays. Also, the controller can be easily obtained by checking the feasibility of the LMI's. Finally, we show the usefulness of our results by an example.

  • PDF

광전극 폭 변화에 따른 W-상호연결 염료감응 태양전지 모듈의 전기적 특성 연구 (Study on the Electrical Properties of W-interconnected DSSC Modules According to Variation of the Working Electrode Width)

  • 오병윤;김상기;김두근
    • 한국전기전자재료학회논문지
    • /
    • 제26권4호
    • /
    • pp.298-303
    • /
    • 2013
  • In this study, the W-interconnected dye-sensitized solar cell (DSSC) modules composed of a number of rectangular cells connected in series were investigated, where neighboring cells are processed in reverse. The DSSC modules, a module of dimension about 200 mm ${\times}$ 200 mm, were fabricated with different working electrode width ranging from 5 mm to 21 mm. The short-circuit current of the module increased as the working electrode width increased. Whereas, the decrease in the working electrode width resulted in the increase of the conversion energy efficiency, fill factor, and open-circuit voltage, which is explained by the fact that the possibility that electrons are recombined along their path on the transparent conductive oxide substrate decreases. The module with the conversion energy efficiency of 3.59% was obtained with the working electrode width of 5 mm.

치수/공차표의 자동생성 알고리듬 (An Algorithm for Automatic Generation of Dimension and Tolerance Charts)

  • 정종인;김광수;최후곤
    • 대한산업공학회지
    • /
    • 제29권1호
    • /
    • pp.21-31
    • /
    • 2003
  • Determination of operational dimensions and tolerances is complex if there exist inconsistencies between operational and design specifications. Dimension and tolerance charts (D&T charts) have been used to establish the relationships among operational dimensions in complex machining. This chart proves that individual operations can be harmonized when they are interconnected. However, it is hard to generate the chart manually. Because operational dimensions and tolerances must meet the design specifications, the dimensions and tolerances of interconnected operations have to be verified serially for economical operations. In this paper, the chart is automatically generated from the interconnected operations. More importantly, all operational dimensions and tolerances displayed in the chart have been verified by using LP to meet the design specifications. Finally, the chart is converted to an operational routing sheet that contains a detailed process plan along with cutting speed, feed rate, and operational references based on material hardness, surface finish, and tool nose radius.