• Title/Summary/Keyword: interception

Search Result 337, Processing Time 0.029 seconds

A Study on the Sound Insulation performance Survey Estimation in Apartment house (공동주택의 소음성능 실측평가에 관한 연구)

  • 함진식;박명길
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

Influence of Radioactive Contamination to Agricultural Products Due to Rain During a Nuclear Accident

  • Won Tae Hwang;Eun Han Kim;Kyung Suk Suh;Moon Hee Han;Han Soo Lee
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.415-420
    • /
    • 2002
  • The previous dynamic food chain model was improved for the consideration of the influence of radioactive contamination to agricultural products due to rain during the environmental releases of radionuclides in a nuclear accident Wet interception coefficients for the agricultural plants were derived as a function of radionuclide and rainfall amount, and mathematical formulations of the previous model were modified. As a result, rain during accidental releases was influential in agricultural contamination. The contamination level of agricultural products decreased dramatically according to increasing rainfall amount. It means that predictive concentrations in agricultural products using the previous model, in which dry interception to the agricultural plants is only considered, can be overestimated. The influence of rainfall in agricultural contamination was the most sensitive for $^{131}$ I, and the least sensitive for $^{90}$ Sr among the radionuclides considered in this study.

A Study on the Sound Insulation Performance Elevation of Floor Structure that use Rubber chip in Apartment House (고무칩을 이용한 공동주택 바닥구조의 차음성능 향상에 관한 연구)

  • 박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.237-332
    • /
    • 2002
  • We constructed ceiling structure and floor structure for elevation of sound insulation performance of concrete slab of apartment house. And, we wished to measure heavy floor impact sound level and light floor impact sound level of these structure. As the result, light floor impact sound level interception performance of concrete slab was measured by thing that construction work of gypsum baud is important. Heavy floor impact sound level interception performance was measured by thing that it is effective that construct to thickness about 30 millimeters on concrete Slav. It was measured effectively that heavy floor impact sound level interception performance constructs rubber chip to thickness about 30 millimeters on concrete Slav.

  • PDF

Throughfall, Stemflow and Interception Loss at Pinus taeda and Pinus densiflora stands (테다소나무림과 소나무림에서의 수관통과우량(樹冠通過雨量), 수간유하우량(樹幹流下雨量) 및 차단손실우량(遮斷損失雨量))

  • Min, Hong-Jin;Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.502-516
    • /
    • 1995
  • The objective of this study was to estimate throughfall, stemflow, interception loss and net rainfall in relation to rainfall interception, and to understand the factors affecting interception process at Pinus taeda stand and Pinus densiflora stand in the Research Forests of Seoul National University, located in Choosan, Kwangyang, Chollanamdo. 1. The gross rainfall during the period of field observation was 3,107.6mm(average 1,035.9mm/year). Most of the daily rainfall intensity was under 30mm, which was 90% in 1992, 81% in 1993 and 88% in 1994. 2. In this study the throughfall, stemflow, interception loss and net rainfall were expressed separately as a function of gross rainfall. The overall throughfall collected during the period of field observation was 2,432.5mm(78.3%) at Pinus taeda stand and 2,699.6mm at Pinus densiflora stand, out of total rainfall of 3107.6mm. The canopy storage capacity, which was determined by the prediction equation between gross rainfall and throughfall was 1.1mm at Pinus taeda stand and 1.3mm at Pinus densiflora stand. 3. The sums of stemflow from measurement of total rainfall at Pinus taeda stand and Pinus densiflora stand was 227.3mm(7.3%) and 62.7mm(2.0%), respectively. The minimum rainfall causing stemflow was estimated as 7.2mm at Pinus taeda stand and 1.9mm at Pinus densiflora stand. 4. Interception loss accounted for 447.8mm(14.4%) at Pinus taeda stand and 345.3mm(11.1%) at Pinus densiflorra stand. 5. Net rainfall was 2,659.8mm(85.6%) at Pinus taeda stand and 2,762.3mm(88.9%) at Pinus densiflora stand. 6. The rates of throughfall and stemflow increased with increasing the gross rainfall. However, the amounts of throughfall and the stemflow were constant above 30mm at Pinus taeda stand and 50mm at Pinus densiflora stand. The rates of interception loss decreased with increasing the gross rainfall. However, the amount of interception loss was constant above 50mm at Pinus taeda stand and Pinus densiflora stand.

  • PDF

Throughfall, Stemflow and Interception Loss of the Natural Old-growth Deciduous and Planted Young Coniferous in Gwangneung and the Rehabilitated Young Mixed Forest in Yangju, Gyeonggido(I) - with a Special Reference on the Results of Measurement - (광릉(光陵) 활엽수(闊葉樹) 천연노령림(天然老齡林)과 침엽수(針葉樹) 인공유령림(人工幼齡林) 그리고 양주(楊洲) 사방지(砂防地) 혼효유령림(混淆幼齡林)의 수관통과우량(樹冠通過雨量), 수간유하량(樹幹流下量) 그리고 차단손실량(遮斷損失量)에 관하여(I) - 실험적(實驗的) 측정결과(測定結果)를 중심(中心)으로 -)

  • Kim, Kyongha;Jun, Jaehong;Yoo, Jaeyun;Jeong, Yongho
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.488-495
    • /
    • 2005
  • This study was conducted to understand the influences of forest structure on throughfall, stemflow and interception loss. The study plots included the natural old-growth deciduous, Pinus koraiensis and Abies holophylla forests in Gwangneung and the rehabilitated young mixed forest in Yangju, Gyeonggido. The Pinus koraiensis and Abies hotophylla had been planted in 1976. The rehabilitated young mixed forest had been established to control erosion in 1974. Total and net rainfall were monitored from March, 2003 to October, 2004. Tipping bucket rain gauge recorded total rainfall. Throughfall and stemflow were measured by custom-made tipping bucket and CR10X data logger at each $10m{\times}10m$ plots at intervals of 30 minutes. Interception loss in the Pinus koraiensis plot were most as 37.2% of total rainfall and least as 22.6% in the rehabilitated young mixed forest. Stemflow in the rehabilitated young mixed forest was 10.7% of total rainfall and stemflow in the Pinus koraiensis plot was 2.4%. The average throughfall ratio ranged from 66% to 77% depending on the canopy coverage. The relationship of stemflow and total rainfall represented in a linear regression equation though the variation of data was large. The ratio of stemflow-conversion was 2% of total rainfall in the Pinus koraiensis plot and 12% in the rehabilitated young mixed forest, respectively. The stem storage of the natural old-growth deciduous was the largest of 0.21 mm whereas that of the Pinus koraiensis plot was the least of 0.003 mm. A deciduous forest produced stemflow more than a coniferous forest due to a smooth bark and steeply angled branches. Interception loss of all study plots increased linearly as total rainfall increased. The distribution of interception loss data related in total rainfall became wider in a deciduous forest than a coniferous. It resulted from seasonality of leaf area index in a deciduous forest. As considered above results, it was confirmed that there were great differences of throughfall, stemflow and interception loss depending on forest stand structures. The simulation model for predicting interception loss must have parameters such as forest stand characteristics and LAI in order to describe the influence of forest structure on interception loss.

Intercepted flow equation at grate inlet on road (도로 빗물받이 유입구의 차집유량 산정식)

  • Kim, Jung Soo;Kwak, Sang Ho;Ryu, Taek Hee;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.537-549
    • /
    • 2016
  • The grate inlets generally were installed to intercept surface runoff on the roads and intercepted flow was drained to the underground sewer system. The equation of interception flow was used to determine the size and spacing of grate inlet on the roads. Therefore, it is necessary to analyze the interception capacity of grate inlet. Hydraulic experimental apparatus which can be changed with the longitudinal slopes(2, 4, 6, 8, 10%) of street, the transverse slopes(2, 4, 7, 10%), and the lengths(50, 100, 150cm) of grate inlet was installed for this study. The range of the experimental discharges were calculated with change of road lanes(2, 3, 4) and design frequencies(5, 10, 20, 30year). As the transverse slope increased, it led to the increase of interception capacity at grate inlets. The long lengths of grate inlet with direction of flow increased the interception capacity by the increase of side inflow. On the basis of the hydraulic model experiment results, the empirical equations for calculation of the interception capacity were derived with regression analysis. As a result of comparison with equations, the suggested equation of this study was estimated reasonable one for increased design frequency. Therefore, this study can suggest the basic data for design of drainage facility at road.

On Estimating Interception Storage Capacity of Litter Layer at Gwangneung Deciduous Forest (광릉 활엽수림의 낙엽층 차단저류능 추정에 관하여)

  • Kang, Min-Seok;Hong, Je-Woo;Bong, Ha-Young;Jang, Hye-Mi;Choi, Myung-Je;Jang, Yoo-Hee;Cheon, Jeong-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.2
    • /
    • pp.87-92
    • /
    • 2011
  • In order to better understand the role of litter layer on hydrological cycle in forest, we estimated the interception storage capacity of the litter layer at Gwangneung deciduous forest. We first made a thickness map of the litter layer at the study site based on field survey and then collected representative litter samples for the laboratory experiment. We constructed a measurement device consisting of sample tray, drain collector, tipping bucket, and a data logger. Using this device, we examined the relationship between the interception storage capacity ($C_i$) and the thickness (d) of the litter layer. For the range of d from 25 to 100 mm, there was a simple linear relationship between $C_i$ and d, which changed with the intensity of the simulated rain. The results were extrapolated to d smaller than 25 mm by considering that no interception occurs without litter layer. Overall, $C_i$ increased rapidly when d was low (< 25 mm) but the rate of increase decreased as d increased due to clumping. With an average thickness of 59 mm, the estimated $C_i$ at the site was 0.94 (${\pm}0.39$) mm. Such an interception storage capacity of the litter layer is comparable to that of the forest canopy, suggesting that the litter layer can play an important role in the forest water cycle.

Development of interception capacity equations according to grate inlet types (빗물받이 형상에 따른 차집량 산정식 개발)

  • Choi, Sung Yeul;Eom, Kwangho;Choi, Seungyong;Cho, Jaewoong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.10
    • /
    • pp.851-861
    • /
    • 2016
  • Recently, natural disasters, which are hard to predict and prevent, are rapidly increasing due to climate change worldwide. Particularly the damage scale of urban areas is increasing because of local torrential rainfall. In urban areas, the rain water cannot flow to pipes well due to the high percentage of impervious areas by the indiscriminate development. As a result, the inundation damage is getting higher in urban areas. So we need to characterize the interception of the grate inlets to ensure good drainage in impervious areas. But Korean installation criteria of grate inlets does not reflect road and drainage sector characteristics so the grate inlets do not function properly in many areas. In this study, we suggest the interception capacity equations about grate inlets through hydraulic experiments in various conditions. Therefore, the interception capacity changes are analyzed according to bearing bar slopes of grate inlets, grate inlet sizes and shapes and connecting pipe numbers. Though this, we developed the interception capacity equations about domestic grate inlets.

An Experimental Study for Clogging Factors Estimation of Grate Inlets in Urban Area (도시지역에서 빗물받이의 막힘계수 산정에 관한 실험적 연구)

  • Kim, Jung Soo;Kwon, In Sup;Yoon, Sei Eui;Lee, Jong Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2B
    • /
    • pp.179-186
    • /
    • 2006
  • Effective interception area of street grate inlets was decreased by clogging with trash, debris, and sand. It also decreased the interception capability of grate inlets and increased the inundation area in street. Therefore, it is necessary to analyze the clogging characteristics and interception capability change by clogging for appropriate design and management of grate inlets. Hydraulic experimental apparatus which can be changed the gutter transverse slopes, longitudinal slopes of street and clogging condition of grate inlet ($40{\times}50cm$) was installed for this study. 81 total experiments were conducted with 8 different clogging condition. The interception capacities of grate inlets clogged curb direction are smaller than those of clogged flow direction. As the longitudinal slopes of street increase, the interception capacity of grate inlet decreases due to splash-over phenomena. This is also observed at grate inlets which has no clogging condition. In general, 50% of clogging factor was selected in design of grate inlet in foreign country. The clogging factor for same clogging condition are suggested 0.25~0.65 in domestic urban area.

Minimum-Time Algorithm for Intercepting an Object by the Robot on Conveyor System (컨베이어 상의 물체 획득을 위한 로봇의 최소시간 알고리즘)

  • Shin, Ik-Sang;Moon, Seung-Bin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.9
    • /
    • pp.795-801
    • /
    • 2005
  • This paper focuses on planning strategies for object interception by the robotic manipulator on a conveyor system in minimum time. The goal is that the robot is able to intercept object with minimum time on a conveyor line that moves at a given speed. The search algorithm for minimum time solution is given in detail for all possible cases for initial locations of robot. Simulations results show the validity of the given algorithm.