• Title/Summary/Keyword: interactive factor

Search Result 256, Processing Time 0.03 seconds

A Study on the Line-Interactive UPS with Power Factor correction (Line - Interactive UPS의 역률 개선 방안에 관한 연구)

  • Jang Hoon;Lee Woo-Cheol;Lee Taeck-Kie;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.93-96
    • /
    • 2001
  • This paper proposed on the Line-Interactive UPS with power factor correction. The paper Line-Interactive UPS topology with its advantages is reviewed. Next introduces Line -Interactive UPS of the series active compensator. The series active compensator controls input currents and power factor.

  • PDF

Validation of the Penn Interactive Peer Play Scale for Korean Young Children with a Special Focus on Confirmatory Factor Analysis (확인적 요인분석을 통한 또래 놀이행동 척도의 타당화)

  • Choi, Hye-Yeong;Shin, Hae-Young
    • Korean Journal of Child Studies
    • /
    • v.32 no.2
    • /
    • pp.35-52
    • /
    • 2011
  • The purpose of this study was to evaluate the validity and reliability of the Penn Interactive Peer Play Scale (PIPPS) for Korean young children, with a special confirmative factor analysis. The participants were composed of 435 5-to 6-year-old children and their parents, and 42 teachers. The instruments included the 32-item exploratory PIPPS (Choi & Shin, 2008), the Preschool Behavior Questionnaire (PBQ; Park, 1992), and the PIPPS on parental reporting. The PIPPS was confirmed, and supported the following constructs resulting in the investigation of 3 factors, 'play disruption', 'play interaction', and 'play disconnection', along with 30 items similar to the PIPPS (2008). Inter-correlations between the sub-factors of PIPPS with those of criterion measures were validated by ratings from the PBQ and the parent version of the PIPPS. The reliability coefficients of the sub-factors of the PIPPS ranged from .85 to .92. In conclusion, 3 factor structure of the PIPPS was appropriate to represent the interactive peer play of Korean young children.

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

The Effect of Using the Interactive Electronic Models in Teaching Mathematical Concepts on Students Achievement in the University Level

  • Alzahrani, Yahya Mizher
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.5
    • /
    • pp.149-153
    • /
    • 2022
  • This study examines the effect of using interactive electronic models to teach mathematical concepts on students' achievement in the linear algebra course at university. The field sample consisted of 200 students divided into two equal groups, an experimental group of 100 students and a control group of 100 students. The researcher used an achievement test in some mathematical concepts related to linear algebra. The results of the study showed that there were statistically significant differences (0.05) between the average achievement scores of the experimental and control groups in the post application of the achievement test, in favor of the experimental group. The size of the influence of the independent factor on the results of the study, which is "interactive electronic forms", on the dependent factor, which is the students' academic achievement in the prepared test, had a very large effect. Also, the results of the study showed that there were statistically significant differences (0.05) between the mean scores of the experimental group in the pre and post applications of the achievement test, in favor of the post application. The researcher recommended the use of interactive electronic models in teaching mathematical concepts at the university level and diversifying the strategies of teaching mathematics, using technology to attract learners and raise their academic achievement.

Source Side Power Factor Correction for Utility Interactive Photovoltaic System (계통연계형 태양광 발전 시스템에서의 전원측 역율 개선)

  • 조영준;김홍성;목형수;최규하;김한성
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.386-392
    • /
    • 1997
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reserve margin in summer. As one of the remedies about this problem, the small scale utility interactive photovoltaic system(UIPVS) is considered for auxiliary power source. For this system one of problems to be solved technically, system operating power factor. Generally in case of small scale system, system is operated in unity power factor. But this unity power factor operating mode decrease power factor viewed from utility because UIPVS supply active power to utility. Therefore this paper propose UIPVS with power factor correcting function and this system is analyzed.

  • PDF

Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter (PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

EMTP Implementation of Power Factor Controller in Utility Interactive Photovoltaic System (EMTP를 이용한 태양광 연계 계통의 역률 제어기 구현)

  • Kim, Sang-Hyub;Rhee, Sang-Bong;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.490-491
    • /
    • 2008
  • A photovoltaic power generation system is one of the ideal clean energy sources increasingly replacing fossil fuel, which has many environmental problems such as exhausted gas or air pollution. As a photovoltaic generation system should meet the requirement to be connected to utility, power factor is an important factor for the high quality of power. This paper implements a power factor controller to improve the power quality of utility interactive photovoltaic system. To verify the effectiveness of the implemented power factor controller, the results by Electromagnetic Transients Program (EMTP) are presented.

  • PDF

A filed operation characteristics and the controversial point of Photovoltaic power generation system (태양광 발전시스템의 현장 운전특성 및 문제점)

  • Koh, Kang-Hoon;Suh, Ki-Young;Lee, Hyun-Woo;Hong, Doo-Sung;Gang, Yeong-Cheol;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

Learning a Second Culture through Interactive Practices: A Study-Abroad Language Learners' Experiences

  • Lee, Eun-Sil
    • English Language & Literature Teaching
    • /
    • v.15 no.4
    • /
    • pp.137-156
    • /
    • 2009
  • This case study examines language learners' oral interactive practices and what they learn along with these practices. Language learners who study abroad take on the challenge of living in a foreign place and undergo difficulties in communicating and interacting with people in their new country. These difficulties, caused by cultural differences, are experienced most particularly in their daily interactions. Language learners' trials and efforts to learn English while dealing with a different culture and the difficulties are mainly observed for this paper. The process of learning a second culture is closely related to the process of learning a second language. Oral interactive practices can give the study abroad language learners opportunities to learn their target culture. Therefore, the purpose of this paper is to discuss how participating in interactive practices assists the learners in understanding their target culture while they deal with their difficulties inherent in studying abroad. This study adds weight to the notion that culture is an essential and major factor in learning a language, and that only active participation in interactions can be effective in learning both a language and its culture.

  • PDF

Optimized LCL filter Design Method of Utility Interactive Inverter (계통연계형 인버터의 LCL필터 최적 설계기법)

  • Jung, Sang-Hyuk;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.