• Title/Summary/Keyword: inter-scale

Search Result 439, Processing Time 0.021 seconds

Distribution Characteristics of the Medical Services in Korea (한국 의료서비스의 분포 특징 분석)

  • Lee Keumsook
    • Journal of the Korean Geographical Society
    • /
    • v.40 no.2 s.107
    • /
    • pp.242-251
    • /
    • 2005
  • This study investigates the distribution characteristics of medical services in Korea. For the purpose this paper examines the spatial discordance between the provisions of the medical services and the need for them, and analyzes the spatial distribution patterns of medical service in both inter- and intra-regional levels. Disclosed is a severe regional disparity problem in the provision of medical facilities at both inter-regional and intra-regional levels. In recent years people's interest gets increased more in the social well-being of the community, and the resulting strong request makes it desirable to restructure the healthcare service system. This study has thus attempted to draw out the distribution function of the medical facilities, based on the examination of the real data. A particular attention has been paid to whether there exists any hierarchical structure in their size distribution. Quite remarkably, no appreciable hierarchical structure has been observed in the scale of the medical facilities in Korea, in sharp contrast to of the three-level hierarchical structure assumed in the three-level referral system adopted widely. Remarkably, it is revealed that medical facilities in Korea are described by scale-invariant distribution functions. Instead, scale-invariant power-law behavior has been found in the size distribution, which is expected to be rather generic and applicable to other countries as well.

Retrieving Protein Domain Encoding DNA Sequences Automatically Through Database Cross-referencing

  • Choi, Yoon-Sup;Yang, Jae-Seong;Ryu, Sung-Ho;Kim, Sang-Uk
    • Bioinformatics and Biosystems
    • /
    • v.1 no.2
    • /
    • pp.95-98
    • /
    • 2006
  • Recent proteomic studies of protein domains require high-throughput and systematic approaches. Since most experiments using protein domains, the modules of protein-protein interactions, require gene cloning, the first experimental step should be retrieving DNA sequences of domain encoding regions from databases. For a large scale proteomic research, however, it is a laborious task to extract a large number of domain sequences manually from several inter-linked databases. We present a new methodology to retrieve DNA sequences of domain encoding regions through automatic database cross-referencing. To extract protein domain encoding regions, it traverses several inter-connected database with validation process. And we applied this method to retrieve all the EGF domain encoding DNA sequences of homo sapiens. This new algorithm was implemented using Python library PAMIE, which enables to cross-reference across distinct databases automatically.

  • PDF

Reliability and Validity of the Korean Version of the Functional Movement Screen (한국판 기능적 동작 검사의 신뢰도와 타당도)

  • An, Seung-Heon;Lee, Je-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.83-93
    • /
    • 2010
  • Purpose: The purpose of this study was to determine the reliability and validity of the Functional Movement Screen (FMS) for assessing Korean athletes. Methods: A total of 48 patients (37 males and 11 females) participated in this study. Data were acquired after translation of the FMS from English to Korean and cross-cultural adaptation of the this questionnaire. To determine inter-rater reliability, the relationship between the FMS scores obtained by two raters was evaluated using the Kappa coefficient, which was in total agreement with the Intra-Correlation Coefficient (ICC3,1). Concurrent validity was examined by correlating the FMS scores with the Oswestry disability index (ODI) scores and Visual analogue scale (VAS) scores. Results: The raters demonstrated excellent agreement on 7 (above 90%) of the 17 test (72.9 to 97.9%) components. Substantial agreement was seen in 11 of the 17 tests. Two components of the In-line lunge and rotatory stability tests demonstrated moderate agreement. It showed good inter-rater reliability: the Kappa coefficients ranged from 0.42 to 0.97. ICC3,1=0.42~0.99 and 0.93 (total FMS score). Cronbach's alpha for FMS was 0.80. It was not correlated with ODI or VAS. Conclusion: The Korean version of the FMS is a reliable instrument for measuring movement patterns of Korean athletes and for making decisions related to interventions for performance enhancement.

CEOP Annual Enhanced Observing Period Starts

  • Koike, Toshio
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.343-346
    • /
    • 2002
  • Toward more accurate determination of the water cycle in association with climate variability and change as well as baseline data on the impacts of this variability on water resources, the Coordinated Enhanced Observing Period (CEOP) was launched on July 1,2001. The preliminary data period, EOP-1, was implemented from July to September in 2001. The first annual enhanced observing period, EOP-3, is going to start on October 1,2002. CEOP is seeking to achieve a database of common measurements from both in situ and satellite remote sensing, model output, and four-dimensional data analyses (4DDA; including global and regional reanalyses) for a specified period. In this context a number of carefully selected reference stations are linked closely with the existing network of observing sites involved in the GEWEX Continental Scale Experiments, which are distributed across the world. The initial step of CEOP is to develop a pilot global hydro-climatological dataset with global consistency under the climate variability that can be used to help validate satellite hydrology products and evaluate, develop and eventually predict water and energy cycle processes in global and regional models. Based on the dataset, we will address the studies on the inter-comparison and inter-connectivity of the monsoon systems and regional water and energy budget, and a path to down-scaling from the global climate to local water resources, as the second step.

  • PDF

The Effect of Scaling of Owl's Flight Feather on Aerodynamic Noise at Inter-coach Space of High Speed Trains based on Biomimetic Analogy

  • Han, Jae-Hyun;Kim, Tae-Min;Kim, Jung-Soo
    • International Journal of Railway
    • /
    • v.4 no.4
    • /
    • pp.109-115
    • /
    • 2011
  • An analysis and design method for reducing aerodynamic noise in high-speed trains based on biomimetics of noiseless flight of owl is proposed. Five factors related to the morphology of the flight feather have been selected, and the candidate optimal shape of the flight feather is determined. The turbulent flow field analysis demonstrates that the optimal shape leads to diminished vortex formation by causing separation of the flow as well as allowing the fluid to climb up along the surface of the flight feather. To determine the effect of scaling of the owl's flight feather on the noise reduction, a two-fold and a four-fold scaled up model of the feather are constructed, and the numerical simulations are carried out to obtain the aerodynamic noise levels for each scale. Original model is found to reduce the noise level by 10 dBA, while two-fold increase in length dimensions reduces the noise by 12 dBA. Validation of numerical solution using wind tunnel experimental measurements is presented as well.

  • PDF

Diagnostic accuracy of digital images for detection of artificial chemical proximal caries (화학적 인공 인접면 치아우식증의 디지털 영상 진단능 평가)

  • Park Geum-Mee;Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.91-95
    • /
    • 2003
  • Purpose : To compare the diagnostic accuracy of proximal caries detection between Kodak Insight film and the Biomedisys CDX2000HQ digital (CCD) sensor. Materials and Methods: 156 proximal surfaces of extracted teeth, 78 of which had chemical artificial caries, were used in this study. Four observers interpreted the radiographs using a five-point confidence rating scale to record their diagnoses. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa values. Result: Analysis using receiver operating characteristic curves revealed the areas under each curve which indicated a diagnostic accuracy of 0.951 in Insight and 0.952 in CDX2000HQ digital sensor. ANOVA revealed no significant differences between the two images with respect to caries detection. Kappa values indicated that the mean intra-observer agreement was 0.85 and inter-observer agreement 0.71 in conventional radiography. In digital radiography, the mean intra-observer agreement was 0.84 and inter-observer agreement 0.72. Conclusion: The results suggest that no significant difference exists between the two modalities for artificial caries detection and that CDX2000HQ was as good as Insight film for this purpose.

  • PDF

Drift displacement data based estimation of cumulative plastic deformation ratios for buildings

  • Nishitani, Akira;Matsui, Chisa;Hara, Yushiro;Xiang, Ping;Nitta, Yoshihiro;Hatada, Tomohiko;Katamura, Ryota;Matsuya, Iwao;Tanii, Takashi
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.881-896
    • /
    • 2015
  • The authors' research group has developed a noncontact type of sensors which directly measure the inter-story drift displacements of a building during a seismic event. Soon after that event, such seismically-induced drift displacement data would provide structural engineers with useful information to judge how the stories have been damaged. This paper presents a scheme of estimating the story cumulative plastic deformation ratios based on such measured drift displacement information toward the building safety monitoring. The presented scheme requires the data of story drift displacements and the ground motion acceleration. The involved calculations are rather simple without any detailed information on structural elements required: the story hysteresis loops are first estimated and then the cumulative plastic deformation ratio of each story is evaluated from the estimated hysteresis. The effectiveness of the scheme is demonstrated by utilizing the data of full-scale building model experiment performed at E-defense and conducting numerical simulations.

A novel hardware design for SIFT generation with reduced memory requirement

  • Kim, Eung Sup;Lee, Hyuk-Jae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.2
    • /
    • pp.157-169
    • /
    • 2013
  • Scale Invariant Feature Transform (SIFT) generates image features widely used to match objects in different images. Previous work on hardware-based SIFT implementation requires excessive internal memory and hardware logic [1]. In this paper, a new hardware organization is proposed to implement SIFT with less memory and hardware cost than the previous work. To this end, a parallel Gaussian filter bank is adopted to eliminate the buffers that store intermediate results because parallel operations allow all intermediate results available at the same time. Furthermore, the processing order is changed from the raster-scan order to the block-by-block order so that the line buffer size storing the source image is also reduced. These techniques trade the reduction of memory size with a slight increase of the execution time and external memory bandwidth. As a result, the memory size is reduced by 94.4%. The proposed hardware for SIFT implementation includes the Descriptor generation block, which is omitted in the previous work [1]. The addition of the hardwired descriptor generation improves the computation speed by about 30 times when compared with the previous work.

A case Study for Protection Relay System of small Cogeneration intertie (소형 열병합 발전기 계통연계 운전시의 적용 보호지침 개선 제안)

  • Yoon, K.K.;Kim, K.S.;Hyun, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.227-230
    • /
    • 2004
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. For Con-Gen users, the several protection relays are recommended to install at the user's main incoming panel by the guide lines and/or instructions of the interconnected utility Then user's main CB(Circuit Breaker) have the chance to be tripped by some of this recommended relays and users have to undergo the unexpected blackout. So the circuit breaker trip schemes targeted to trip with these protection relays are reconsidered and the study result is hereunder proposed.

  • PDF

Analyzing the Impact of Social Distancing on the Stoning Ritual of the Islamic Pilgrimage

  • Ilyas, Qazi Mudassar;Ahmad, Muneer;Jhanjhi, Noor Zaman;Ahmad, Muhammad Bilal
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.6
    • /
    • pp.1953-1972
    • /
    • 2022
  • The COVID-19 pandemic has resulted in a profound impact on large-scale gatherings throughout the world. Social distancing has become one of the most common measures to restrict the spread of the novel Coronavirus. Islamic pilgrimage attracts millions of pilgrims to Saudi Arabia annually. One of the mandatory rituals of pilgrimage is the symbolic stoning of the devil. Every pilgrim is required to perform this ritual within a specified time on three days of pilgrimage. This ritual is prone to congestion due to strict spatiotemporal requirements. We propose a pedestrian simulation model for implementing social distancing in the stoning ritual. An agent-based simulation is designed to analyze the impact of inter-queue and intra-queue spacing between adjacent pilgrims on the throughput and congestion during the stoning ritual. After analyzing several combinations of intra-queue and inter-queue spacings, we conclude that 25 queues with 1.5 meters of intra-queue spacing result in an optimal combination of throughput and congestion. The Ministry of Hajj in Saudi Arabia may benefit from these findings to manage and plan pilgrimage more effectively.