• 제목/요약/키워드: intelligent cooling control

검색결과 16건 처리시간 0.026초

변압기 냉각시스템의 지능제어알고리즘 (The Intelligent Control Algorithm of a Transformer Cooling System)

  • 한도영;원재영
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.515-522
    • /
    • 2010
  • In order to improve the efficiency of a transformer cooling system, the intelligent algorithm was developed. The intelligent algorithm is composed of a setpoint algorithm and a control algorithm. The setpoint algorithm was developed by the neural network, and the control algorithm was developed by the fuzzy logic. These algorithms were used for the control of a blower and an oil pump of the transformer cooling system. In order to analyse performances of these algorithms, the dynamic model of a transformer cooling system was used. Based on various performance tests, energy savings and stable controls of a transformer cooling system were observed. Therefore, control algorithms developed for this study may be effectively used for the control of a transformer cooling system.

Intelligent cooling control for mass concrete relating to spiral case structure

  • Ning, Zeyu;Lin, Peng;Ouyang, Jianshu;Yang, Zongli;He, Mingwu;Ma, Fangping
    • Advances in concrete construction
    • /
    • 제14권1호
    • /
    • pp.57-70
    • /
    • 2022
  • The spiral case concrete (SCC) used in the underground powerhouse of large hydropower stations is complex, difficult to pour, and has high requirements for temperature control and crack prevention. In this study, based on the closed-loop control theory of "multi-source sensing, real analysis, and intelligent control", a new intelligent cooling control system (ICCS) suitable for the SCC is developed and is further applied to the Wudongde large-scale underground powerhouse. By employing the site monitoring data, numerical simulation, and field investigation, the temperature control quality of the SCC is evaluated. The results show that the target temperature control curve can be accurately tracked, and the temperature control indicators such as the maximum temperature can meet the design requirements by adopting the ICCS. Moreover, the numerical results and site investigation indicate that a safety factor of the spiral case structure was sure, and no cracking was found in the concrete blocks, by which the effectiveness of the system for improving the quality of temperature control of the SCC is verified. Finally, an intelligent cooling control procedure suitable for the SCC is proposed, which can provide a reference for improving the design and construction level for similar projects.

승강기용 냉각장치의 에너지 절감을 위한 사람 검출과 퍼지 온도 제어 시스템 (Human Detection and Fuzzy Temperature Control System for Energy Reduction of Cooling Device in Elevator)

  • 음혁민;장석윤;이희진;박민용;윤창용
    • 한국지능시스템학회논문지
    • /
    • 제25권2호
    • /
    • pp.147-154
    • /
    • 2015
  • 본 논문에서는 승강기용 냉각장치의 에너지 절감을 위한 사람 검출과 퍼지 온도 제어 시스템을 제안한다. 기존의 냉매를 사용하는 냉각장치의 문제점들을 개선하기 위해 사람 검출과 퍼지 온도 제어 시스템으로 열전냉각장치를 구동시켜 에너지 절감을 하고 자동적으로 효율적인 온도 관리를 한다. 제안된 시스템은 사람 검출을 통해 승강기 탑승 인원수를 확인하고 나서 퍼지 시스템에서 탑승 인원수와 계절 평균 기온을 기반으로 온도 제어를 한다. 사람 검출 방법은 승강기에서 조감도 카메라를 기반으로 사람의 머리 부분을 특징으로 사용하여 탑승 인원수를 검지한다. 퍼지 시스템은 look-up table 방법으로서 검지된 인원수와 기온을 고려하여 승강기의 내부 온도를 결정한다. 제안된 시스템은 사람 검출과 온도 제어를 통해 냉각장치의 에너지를 절감시킨다. 실험을 통해 에너지 절감을 확인하고 제안된 시스템의 성능을 검증한다.

DEVELOPMENT OF INTELLIGENT POWER UNIT FOR HYBRID FOUR-DOOR SEDAN

  • Aitaka, K.;Hosoda, M.;Nomura, T.
    • International Journal of Automotive Technology
    • /
    • 제4권2호
    • /
    • pp.57-64
    • /
    • 2003
  • The Intelligent Power Unit (IPU) utilized in Honda's Civic Hybrid Integrated Motor Assist (IMA) system was developed with the aim of making every component lighter, more compact and more efficient than those in the former model. To reduce energy loss, inverter efficiency was increased by fine patterning of the Insulated Gate Bipolar Transistor (IGBT) chips, 12V DC-DC converter efficiency was increased by utilizing soft-switching, and the internal resistance of the IMA battery was lowered by modifying the electrodes and the current collecting structure. These improvements reduced the amount of heat generated by the unit components and made it possible to combine the previously separated Power Control Unit (PCU) and battery cooling systems into a single system. Consolidation of these two cooling circuits into one has reduced the volume of the newly developed IPU by 42% compared to the former model.

퍼지 Look-up Table을 이용한 엔진 다이나모메타 시스템의 트로틀 벨브 제어 (The Throttle Valve Control of engine Dynamometer system Using Fuzzy Look-up Table)

  • 이상윤;이팔진;신위재;김치원
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1995년도 추계학술대회 학술발표 논문집
    • /
    • pp.125-130
    • /
    • 1995
  • Recently, the vehicle engine requried precision control of Air-Fuel rate and rigid restriction of exhaust gas. Therefore, we demanded excellent measuring equipment so as to improve of engine performance. Specially, throttle valve control is very important part in the engine control, because structure of engine dynamometer system is very important part in the engine control, because structure of engine dynamometer system is very complicate and it has nonlinear elements which is influenced of disturbance about vibration, a heat, a cooling, energy loss so on. In this study, we propose the method that the control technique using Fuzzy Look-up table and we obtained the satisfying result from realized the control system.

  • PDF

Fuzzy-Neuro Controller for Control of Air-Conditioning System

  • Lee, Sang-Bae
    • 한국지능시스템학회논문지
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 1995
  • A practical application of a fuzzy-neuro controller is described for an air-conditioning system. Air-handing units are being widely used for improving the performance of central air-conditioning systems. The fuzzy-neuro control system has two controlled variables, temperature and humidity and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical contorl, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy-neuro control system is described for controlling air-conditioning systems efficiently and economically. Simulation results confirmed that the fuzzy neuro control system is effective for this multivariable system.

  • PDF

적분형 최적 레귤레이터 적용 시스템 히트펌프 제어 시뮬레이션 연구 (Numerical Simulation of a System Heat Pump Adopting an Integral Optimum Regulating Controller)

  • 김용찬;최종민
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.398-405
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system that utilizes package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance, along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only an easy distribution control, allowing free combination of indoor units with different models and different capacities, but also wide applications to intelligent air conditioning. However, the control algorithms of the system heat pump are limited in the open literature, due to complicated operating conditions. In this paper, an inverter-driven system heat pump having two indoor units with electronic expansion valves (EEV) was simulated in the cooling mode. An integral optimum regulating controller employing the state space control method was also simulated, and applied to the system-heat pump system, to obtain efficient control of the MIMO (multi input multi output) system. The simulation model for the controller yielded satisfactory prediction results. The new control model can be successfully utilized as a basic tool in controller design.

Hot Gas를 이용한 오일쿨러의 성능평가 (Performances of Hot Gas Bypass Type Oil Cooler System)

  • 이승우;염한길;박길종
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.73-80
    • /
    • 2009
  • In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with machine tools. For precise temperature control, both cooling and heating should be implemented. A hot gas bypass type cooling cycle method has a simplified structure and temperature control accuracy to with in ${\pm}0.1^{\circ}C$. In this study, the performances of oil cooler system, including temperature controllability according to hot gas floe and preset temperature sustainability according to temperature load, were tested. It is expected that this study will contribute to the development and performances of oil cooler system, which could minimize thermal errors and improve the quality of precision machine tools.

IR 카메라 기반의 풍력발전용 고장검출 시스템 개발 (Development of IR Camera based Fault Detection System for Wind Turbine Generator)

  • 김세윤;김성호
    • 한국지능시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.780-785
    • /
    • 2012
  • 최근 풍력발전은 전 세계적으로 전기의 생산을 위해 사용되는 신재생 에너지원 중 가장 빨리 성장하고 있는 분야이다. 일반적으로 풍력발전 시스템은 설치 후 약 20년 동안 사용될 수 있도록 설계되며 따라서 장기간 운전할 경우, 풍력 발전기에서의 고장은 필연적으로 발생하게 된다. 특히 풍력발전 시스템의 너셀 내부에는 로터샤프트, 기어박스 및 발전기 등이 설치되며 이들 요소의 정상적인 동작을 보장하기 위한 각종 냉각 시스템이 설치된다. 만일 이들 냉각 시스템에 고장이 발생된다면 전체 풍력발전시스템의 정상적인 동작을 보장하는 것이 불가능하다. 이에 본 연구에서는 풍력발전 시스템 너셀 내부에 설치되는 각종 냉각장치의 고장을 미연에 방지할 수 있게 하는 IR 카메라 기반의 풍력발전용 고장검출 시스템을 제안하고 실제 시스템의 구현을 통해 제안된 기법의 유용성을 확인하고자 한다.

120km/h급 교류 전동차용 추진제어장치(Converter/Inverter) 개발 및 성능 특성 (Development and Performance Characteristic of Propulsion System (Converter/Inverter) for 120km/h AC Electric Vehicle)

  • 김태윤;노애숙;김명룡;백광선;이상준;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1214-1221
    • /
    • 2006
  • In this paper, development and performance characteristic of propulsion system(Converter/Inverter) using IPM(Intelligent Power Module) for 120km/h AC electric vehicle is proposed. The proposed propulsion system is comprised of IPM converter and inverter stack which uses natural air-cooling system, DC-Link, OVCRf unit and control unit. And also 2-Parallel operation of two PWM converter is adopted for increasing capacity of system and the VVVF inverter control is used a mixed control algorithm, where the vector control strategy at low speed region and slip-frequency control strategy at high speed region. The proposed propulsion system is verified by main line test results as well as combined test results.

  • PDF