• 제목/요약/키워드: integrating sphere

검색결과 68건 처리시간 0.037초

액상유체 환경하에서 레이저빔의 산란 해석 (Laser Beam Scattering Analysis in Aqueous Environments)

  • 최해운
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.91-95
    • /
    • 2019
  • A new experimental approach is proposed to detect a specific polymer dissolved in a liquid. Distinctive optical properties were found using a laser scattering technique when there is a polymer compound with almost no difference in optical properties (index of refraction) in a liquid phase. The index of refraction, which determines the refraction of light, is obtained by dissolving PCL and PLA. The used samples are biodegradable materials with similar properties and dissolved in a mixture of Chloroform 7: Methanol 3. To predict the optical properties, a 632-nm diode laser was used as the light source of the device, and an integrating sphere was used as the light receiver. Although PCL and PLA had a similar index of refraction of 1.46-1.48, the dissolved PCL showed a relative transmittance of 43%, and the dissolved PLA had a relative transmittance of 34%. The difference in optical properties of the pure polymer compound in the solid state or liquid state is not significantly different, and the difference in the dissolved state in the specific solvent is remarkable because the solubility differs in a specific solution and is randomly distributed.

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

비파괴 분석 방법인 푸리에 변환 근적외선 분광 분석을 이용한 한지 기록물의 산성도 및 함수율 정량 분석 연구 (The study of quantitative analytical method for pH and moisture of Hanji record paper using non-destructive FT-NIR spectroscopy)

  • 신용민;박성배;이창영;김찬봉;이성욱;조원보;김효진
    • 분석과학
    • /
    • 제25권2호
    • /
    • pp.121-126
    • /
    • 2012
  • 한지기록물의 상태를 평가하는 데 있어 기록물의 훼손을 방지하는 것은 필수적인 요소이다. 사용된 공시재료는 1900년대 생산된 한지기록물을 사용하였다. 이 종이 기록물의 상태를 평가하기 위하여 비파괴적 분석기인 12,500~4,000 $cm^{-1}$ 파장영역을 가진 푸리에변환(FT) 근적외선 분광 분석기를 이용하였다. 푸리에변환 방식의 간섭계는 뛰어난 정밀도와 정확도를 가지며, 신호-대-잡음비가 가장 우수 하여 정량 분석에서 가장 많이 사용되고 있다. 한지기록물의 산성도와 함수율을 적분구(integrating sphere)의 확산반사로 사용하여 측정하였다. 산성도(pH)의 경우에 전처리를 하지 않았을 때의 상관계수($R^2$)는 0.92, 표준예측오차(SEP)는 0.317이었고, 전처리를 하였을 때의 $R^2$는 0.98, SEP는 0.208 이었다. 그리고 함수율의 경우 산성도와 달리 전처리를 하지 않았을 경우에도 $R^2$와 SEP는 각각 0.99와 0.458로 확인 되었다. 전처리 중 다산란 보정방법(MSC)의 경우에는 $R^2$가 0.97, SEP가 0.558로 증가하는 것을 확인 할 수 있어 함수율은 전처리를 하지 않았을 때가 좋은 결과가 나오는 것으로 확인 되었다. 이러한 결과를 통해 비파괴적인 분석방법으로 한지기록물을 적분구와 FT 근적외선 분광 분석기를 이용하여 한지의 상태를 정확히 평가할 수 있을 것으로 판단되었다.

QUICK DETERMINATION OF MEAT COLOR, METMYOGLOBIN FORMATION AND LIPID OXIDATION IN BEEF, PORK AND CHICKEN BY NEAR-INFRARED SPECTROSCOPY

  • Mitsumoto, Mitsuru;Sasaki, Keisuke;Murakami, Hitoshi
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1259-1259
    • /
    • 2001
  • Meat becomes brown and rancid during storage in the refrigerator and display in the case. Color changes, metmyoglobin formation and lipid oxidation are the important problems in the transportation / distribution of meat and retail display. The freshness of meat is determined by the sense of vision and smell. Since conventional method determining lipid oxidation is time consuming and destructive (it needs to homogenize meat with reagents, filtrate, time for reaction and read optical density using spectroscopy), more rapid and nondestructive technical tools are desired. The objective of this work was to evaluate near-infrared spectroscopy as an analytical tool for determining meat color, metmyoglobin formation and lipid oxidation. in beef, pork and chicken. Semitendinosus and longissimus thoracis muscles from six beef steers, biceps femoris and longissimus thoracis muscles from twelve LWD crossbred pigs, and superficial pectoral muscles from twenty-four broilers were used. About a 5-cm diameter and 1-cm thick sample (20.0g) was cut from the muscle and placed on plastic foam, over-wrapped with PVC film, and displayed under flourescent lights at 4 degrees C. during 10 days for beef and pork or 4 days for chicken. The spectra was measured by NIR systems Model 5500 Spectrophotometer using fiber optic scan at range of 400 - 1100 nm. Data were recorded at 2 nm intervals and 10 scans / 10 sec were averaged for every sample. Data obtained were saved as log 1/Re, where Re is the reflectance energy, and then mathematically transformed to second derivatives to reduce effects of differences in particle size. $L^{*}$, $a^{*}$ and $b^{*}$, and metmyoglobin formation were determined by conventional spectrophotometer using the integrating sphere unit. 2-Thiobarbituric acid reactive substances (TBARS) were measured for lipid oxidation. A multiple linear regression was used to find the equation which would best fit the data. The number of wavelengths used in the equation was selected based on the fewer number compared to the increasing multiple correlation and Decreasing standard error. (omitted)

  • PDF

Design of IGRINS Wavelength Calibration System

  • 오희영;박수종;육인수;박찬;이상은;천무영;김강민;이성호;표태수
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • IGRINS (the Immersion GRating Infrared Spectrograph) is a high resolution infrared spectrograph which is being developed by a collaboration of the University of Texas, the Korea Astronomy and Space Science Institute, and Kyung Hee University. The wavelength calibration unit of IGRINS will be situated between the telescope flange and IGRINS dewar. It will include Th-Ar hallow cathode lamp, optical elements, and gas absorption cell for the case that requires precise calibration (e.g., radial velocity observation). The system will also use a tungsten halogen lamp in an integrating sphere as a blackbody source for the flat-field imaging. IGRINS will be placed initially on the McDonald 2.7m Harlan J. Smith telescope and later on 4-8m class telescopes. We present an overview of the plan for the wavelength calibration sources and of the development process for the optical and mechanical design of the IGRINS calibration system.

  • PDF

LCD 기판 검사 광학계의 MTF 측정장치 제작 (MTF Measuring Equipment of Optical System for LCD Substrate Inspection)

  • 홍성목;김희남;조재흥;이윤우;이회윤;양호순;이인원;정진호
    • 한국광학회지
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2007
  • LCD(liquid crystal display) 기판의 표면검사용 광학장치의 성능평가를 위한 변조전달함수 측정장치를 설계하고 제작하였다. 이 장치에는 3개의 막대물체 모양의 USAF(United States Air Force) 해상도 물체와 적분구로 구성한 물체발생장치와 2차원 CCD(charge coupled device)의 상분석 장치를 사용하였다. 시험렌즈의 변조전달함수는 물체와 상의 명암비를 나눈 명암전달함수를 구한 후 변조 전달함수로 보정하여 변환시켰다. 제작된 평가장치를 이용하여 배율 2.6배, F/13.65의 시험 광학계를 평가하였으며, 공간주파수 62.5 1p/mm에서 자오면에 대해서 30.6 %, 구결면에 대해서 26.1 %의 값을 얻었다.

산소 유량별 플라즈마 방출광원 세기에 따른 전자온도 진단과 산화주석박막 특성연구 (Study on Electron Temperature Diagnostic and the ITO Thin Film Characteristics of the Plasma Emission Intensity by the Oxygen Gas Flow)

  • 박혜진;최진우;조태훈;윤명수;권기청
    • 한국표면공학회지
    • /
    • 제49권1호
    • /
    • pp.92-97
    • /
    • 2016
  • The plasma has been used in various industrial fields of semiconductors, displays, transparent electrode and so on. Plasma diagnostics is critical to the uniform process and the product. We use the electron temperature of the various plasma parameters for the diagnosis of plasma. Generally, the range of the electron temperature which is used in a semiconductor process used the range of 1 eV to 10 eV. The difference of electron temperature of 0.5 eV has a influence in plasma process. The electron temperature can be measured by the electrical method and the optical method. Measurement of electron temperature for various gas flow rates was performed in DC-magnetron sputter and Inductively Coupled Plasma. The physical properties of the thin film were also determined by changing electron temperatures. The transmittance was measured using the integrating sphere, and wavelength range was measured at 300 ~ 1100 nm. We obtain the thin film of the mobility, resistivity and carrier concentration using the hall measurement system. As to the electron temperature increase, optical and electrical properties decrease. We determine it was influenced by the oxygen flow ratio and plasma.

페로브스카이트 할로겐화물 박막의 발광 측정 조건에 따른 특성 분석 (Photoluminescence Characterization of Halide Perovskite Films according to Measuring Conditions)

  • 조현아;이승민;노준홍
    • 한국재료학회지
    • /
    • 제32권10호
    • /
    • pp.419-424
    • /
    • 2022
  • Halide perovskite solar cells (PSCs) have improved rapidly over the past few years, and research on the optoelectrical properties of halide perovskite thin films has grown as well. Among the characterization techniques, photoluminescence (PL), a method of collecting emitted photons to evaluate the properties of materials, is widely applied to evaluate improvements in the performance of PSCs. However, since only photons emitted from the film in the escape cone are included, the photons collected in PL are a small fraction of the total photons emitted from the film. Unlike PSCs power conversion efficiency, PL measuring methods have not been standardized, and have been evaluated in a variety of ways. Thus, an in-depth study is needed of the methods used to evaluate materials using PL spectra. In this study, we examined the PL spectra of the perovskite light harvesting layer with different measurement protocols and analyzed the features. As the incident angle changed, different spectra were observed, indicating that the PL emission spectrum can depend on the measuring method, not the material. We found the intensity and energy of the PL spectra changes were due to the path of the emitted photons. Also, we found that the PL of halide perovskite thin films generally contains limited information. To solve this problem, the emitted photons should be collected using an integrating sphere. The results of this study suggest that the emission spectrum of halide perovskite films should be carefully interpreted in accordance with PL measuring method, since PL data is mostly affected by the method.

Preflight Calibration Results of Wide-Angle Polarimetric Camera (PolCam) onboard Korean Lunar Orbiter, Danuri

  • Minsup Jeong;Young-Jun Choi;Kyung-In Kang;Bongkon Moon;Bonju Gu;Sungsoo S. Kim;Chae Kyung Sim;Dukhang Lee;Yuriy G. Shkuratov;Gorden Videen;Vadym Kaydash
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.293-299
    • /
    • 2023
  • The Wide-Angle Polarimetric Camera (PolCam) is installed on the Korea's lunar orbiter, Danuri, which launched on August 5, 2022. The mission objectives of PolCam are to construct photometric maps at a wavelength of 336 nm and polarization maps at 461 and 748 nm, with a phase angle range of 0°-135° and a spatial resolution of less than 100 m. PolCam is an imager using the push-broom method and has two cameras, Cam 1 and Cam 2, with a viewing angle of 45° to the right and left of the spacecraft's direction of orbit. We conducted performance tests in a laboratory setting before installing PolCam's flight model on the spacecraft. We analyzed the CCD's dark current, flat-field frame, spot size, and light flux. The dark current was obtained during thermal / vacuum test with various temperatures and the flat-field frame data was also obtained with an integrating sphere and tungsten light bulb. We describe the calibration method and results in this study.

현장관측용 분광 광도계의 상대 검교정 시스템 개발 (Development of relative radiometric calibration system for in-situ measurement spectroradiometers)

  • 오은송;안기범;강혁모;조성익;박영제
    • 대한원격탐사학회지
    • /
    • 제30권4호
    • /
    • pp.455-464
    • /
    • 2014
  • 천리안해양관측위성(Geostationary Ocean Color Imager, GOCI)이 2010년 6월에 발사된 이후, 영상 자료의 보정과 검증을 위한 여러 차례의 현장 관측이 한반도 주변에서 수행되었다. 한국해양과학기술원 해양위성센터(Korea Ocean Satellite Center, KOSC)에서는 Analytical Spectral Devices (ASD)사의 분광 광도계 FieldSpec3나 TriOS사의 분광 광도계 RAMSES와 같은 현장관측장비의 특성 변화를 확인하기 위하여 미국국립표준기술원(National Institute of Standards and Technology, NIST)의 표준화 절차를 거친 광원과 표준 분광 광도계를 이용하여 각각의 현장 관측 마다 기기의 성능을 측정하였다. 본 논문에서는 해양위성센터에 구축된 광학 실험실과 현장관측 분광 광도계의 상대적 복사 검교정 방법에 대해서 소개하고 있다. 광학 실험실은 98% 이상의 광원 균질성을 지니는 20인치 적분구(USS-2000S, LabSphere)와 360 nm 부터 1100 nm 까지 1.6 nm 파장 간격으로 측정이 가능한 표준 분광 광도계(MCPD9800, Photal), 그리고 ${\pm}0.1mm$의 편평도를 가지는 광학테이블($3600{\times}1500{\times}800mm^3$)을 기본으로 구성되어 있다. 실험실 내부는 정확한 검교정 실험을 위하여 일정한 온습도를 유지하고 있으며, 동일한 광원에 동일한 위치에서 표준과 현장관측용 분광 광도계를 동시에 측정하는 방법을 기본으로 한다. 해양위성센터가 보유하고 있는 ASD 를 측정한 결과, 현장관측용 분광광도계의 결과가 푸른 가시광 영역에서 미세한 차이가 측정 시 마다 나타나는 것을 확인하였고, 더불어 1년간의 상대 검교정 실험에 따르면 평균적으로 4.41% 정도의 파장별 광특성이 변화하는 것을 확인하였다. 이러한 결과는 측정 정확도를 유지하고, GOCI 자료의 신뢰도를 확보하기 위하여 지속적인 검교정 실험을 수행해야 하는 이유를 보여주고 있다.