• Title/Summary/Keyword: integrated solar radiation

Search Result 97, Processing Time 0.019 seconds

An Experimental Study on the Characteristics of Flux Density Distributions produced by Solar Concentrating System (태양열 집광기의 플럭스 밀도 분포 특성에 관한 연구)

  • Kang Myeongcheol;Kang Yongheack;Yoon Hwanki;Yu Changkyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.422-426
    • /
    • 2005
  • This experimental study represents the results of an analysis on the characteristics of flux density distribution in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This was deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17m. The total integrated power and percent power was 2467W and $85.8\%$, respectively, in the case of small dish, and also 2095W and $79\%$, respectively, in the case of KIERDISH II. As a result of the percent power within radius, approximately $90\%$ of the incident radiation is intercepted by about 0.06 m radius. The minimum radius of receiver in KIERDISH II is found to be 0.15m and approximately $90\%$ of the incident radiation is intercepted by receiver aperture.

  • PDF

Analysis of Generation Characteristics of a Bifacial BIPV System According to Installation Methods (양면형 BIPV 시스템의 설치환경에 따른 발전특성 분석)

  • Kang, Jun Gu;Kim, Jin Hee;Kim, Jun Tae
    • Current Photovoltaic Research
    • /
    • v.3 no.4
    • /
    • pp.121-125
    • /
    • 2015
  • BIPV system is one of the best ways to harness PV module. The BIPV system not only produces electricity, but also acts as a building envelope. Thus, it has the strong point of increasing the economical efficiency by applying the PV modules to the buildings. Bifacial solar cells can convert solar energy to electrical energy from both sides of the module. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial soalr cells. Therefore, many of the module manufacturers can easily produce the bifacial solar cells without changing their manufacturing equipment. Moreover, bifacial BIPV system has much potential in building application by utilizing glass to glass structure. However, the performance of bifacial solar cells depends on a variety of factors, ranging from the back surface to surrounding conditions. Therefore, in order to apply bifacial solar cells to buildings, an analysis of bifacial PV module performance should be carried out that includes a consideration of various design elements, and reflects a wide range of installation conditions. As a result it found that the white insulation reflector type can improve the performance of the bifacial BIPV system by 16%, compared to the black insulation reflector type. The performance of the bifacial BIPV was also shown to be influenced by inclination angle, due to changes in both the amount of radiation captured on the front face and the radiation transmitted to the rear face through the transparent space. In this study is limited design condition and installation condition. Accordingly follow-up researches in this part need to be conducted.

Case Study on 12kW Building Integrated Photovoltaic System (12kW급 건물일체형 태양광발전시스템 사례분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;So, Jung-Hoon;Yu, Gwon-Jong;Kim, Jun-Tae;Lee, Kil-Song
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

A Study on Energy Distributions Produced by Dish Solar Concentrating System (접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구)

  • 현성택;강용혁;천원기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.

Evaluation of Heat Waves Predictability of Korean Integrated Model (한국형수치예보모델 KIM의 폭염 예측 성능 검증)

  • Jung, Jiyoung;Lee, Eun-Hee;Park, Hye-Jin
    • Atmosphere
    • /
    • v.32 no.4
    • /
    • pp.277-295
    • /
    • 2022
  • The global weather prediction model, Korean Integrated Model (KIM), has been in operation since April 2020 by the Korea Meteorological Administration. This study assessed the performance of heat waves (HWs) in Korea in 2020. Case experiments during 2018-2020 were conducted to support the reliability of assessment, and the factors which affect predictability of the HWs were analyzed. Simulated expansion and retreat of the Tibetan High and North Pacific High during the 2020 HW had a good agreement with the analysis. However, the model showed significant cold biases in the maximum surface temperature. It was found that the temperature bias was highly related to underestimation of downward shortwave radiation at surface, which was linked to cloudiness. KIM tended to overestimate nighttime clouds that delayed the dissipation of cloud in the morning, which affected the shortage of downward solar radiation. The vertical profiles of temperature and moisture showed that cold bias and trapped moisture in the lower atmosphere produce favorable conditions for cloud formation over the Yellow Sea, which affected overestimation of cloud in downwind land. Sensitivity test was performed to reduce model bias, which was done by modulating moisture mixing parameter in the boundary layer scheme. Results indicated that the daytime temperature errors were reduced by increase in surface solar irradiance with enhanced cloud dissipation. This study suggested that not only the synoptic features but also the accuracy of low-level temperature and moisture condition played an important role in predicting the maximum temperature during the HWs in medium-range forecasts.

Effects of Harvest Time on Growth and Phytochemical Contents of Baby Leaf Vegetables in Multi-layer System (다단재배에서 수확시기가 어린잎 채소의 생육과 항산화물질 함량에 미치는 영향)

  • Kim, Jae Kyung;Kang, Ho Min;Kim, Il Seop;Choi, Eun Young;Choi, Ki Yong
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.194-200
    • /
    • 2017
  • This study aimed to determine the suitable of harvest time on the growth and quality of baby leafy vegetables (Agastsche rugosa O. Kuntze and Lepidium sativum L.) grown on rice seedling tray in a six-layered bench system at 30cm intervals in order to exploit the space during rice growing off-season. Seedlings were grown on the rice seedling tray for 10 days after sowing with coir substrate supplied with nutrient solution at EC $1.5dS{\cdot}m^{-1}$ every 2 days prior to placing the tray on the bench, which were at $1^{st}$ (Low) layer above 20cm and $6^{th}$ (High) layer above 170cm apart from the ground. Growth and phytochemical contents were measured at 7-day and 14-day harvest time. During the culture periods, daily average of integrated solar radiation and temperature were $9.3{\sim}9.6MJ{\cdot}m^{-2}$, $27.5^{\circ}C$ in the High layer and $5.1{\sim}6.2MJ{\cdot}m^{-2}$ in average, and $26.5{\sim}26.6^{\circ}C$ in the Low layer, respectively. For A. rugosa, the highest growth was observed in the Low layer bench at a 14-day harvest time, while their plant height in the High layer was shorter and the leaf number was lower. For L. sativum, the plant height, leaf length and width, leaf number and fresh weight were higher in the Low layer. For A. rugosa, a high yield was observed with the increase in integrated temperature and integrated solar radiation, while a higher yield of L. sativum was found with the increase in integrated temperature, but not with integrated solar radiation. For A. rugosa, both polyphenol and anthocyanin contents were higher in the High layer at a 14-day harvest time. For L. sativum, polyphenol contents were higher in the High layer, whereas no significant difference in anthocyanin and flavonoid contents was observed depending on the layer and harvest time. The highest chlorophyll content showed in Low layer at a 7-day harvest time in both A. rugose and L. sativum. All of the results suggest that in terms of growth and quality, it may be better growing in the high layer for 14 days after seedling in A. rugosa, and low layer for 7 days in L. sativum.

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

The Development of an Intelligent Home Energy Management System Integrated with a Vehicle-to-Home Unit using a Reinforcement Learning Approach

  • Ohoud Almughram;Sami Ben Slama;Bassam Zafar
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.87-106
    • /
    • 2024
  • Vehicle-to-Home (V2H) and Home Centralized Photovoltaic (HCPV) systems can address various energy storage issues and enhance demand response programs. Renewable energy, such as solar energy and wind turbines, address the energy gap. However, no energy management system is currently available to regulate the uncertainty of renewable energy sources, electric vehicles, and appliance consumption within a smart microgrid. Therefore, this study investigated the impact of solar photovoltaic (PV) panels, electric vehicles, and Micro-Grid (MG) storage on maximum solar radiation hours. Several Deep Learning (DL) algorithms were applied to account for the uncertainty. Moreover, a Reinforcement Learning HCPV (RL-HCPV) algorithm was created for efficient real-time energy scheduling decisions. The proposed algorithm managed the energy demand between PV solar energy generation and vehicle energy storage. RL-HCPV was modeled according to several constraints to meet household electricity demands in sunny and cloudy weather. Simulations demonstrated how the proposed RL-HCPV system could efficiently handle the demand response and how V2H can help to smooth the appliance load profile and reduce power consumption costs with sustainable power generation. The results demonstrated the advantages of utilizing RL and V2H as potential storage technology for smart buildings.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

Control of Environments in Greenhouse Using Programmable Logic Controller (PLC를 이용한 온실의 환경제어)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF