Understanding and Improvement of Best Available Techniques for Waste Incineration Facility (폐기물 소각시설 최적가용기법 (BAT) 기준서의 이해와 개선방향)

  • Shin, Sujeong;Park, Jae-Hong;Park, Sang-Ah;Lee, DaeGyun;Kim, Dai-Gon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.533-543
    • /
    • 2017
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In order to facilitate the implementation of integrated environmental pollution prevention act with these advantages, the BAT BREF should be published, modified and revised every 5 years considering the level of scientific development. This study reviewed the issues to be considered in applying BAT and the types of BAT and focused on presenting improvements and development direction when revising and supplementing the standards in the future based on these contents. For this purpose, when revising the standards, it will be necessary to reflect on the domestic situation, to expand the TWG(Technical Working Group) of small-scale workplace experts, and to exchange opinions with business places that have similar processes for each waste type through a systematic total inspection. In addition to these methods, by establishing a resident participation system through information disclosure, it is expected to be used as a guideline for environmental management of business places not subject to integrated permission of less than 3 types as well as those subject to integrated permission.

An Integrated Inventory Model for Two-Product Single-Facility System

  • Choi, Sung-Bin;Moon, Dug-Hee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.12 no.1
    • /
    • pp.31-41
    • /
    • 1986
  • In this paper, an integrated production inventory model is developed for two products on a single facility in which the raw materials are fed to the production system as required at the facility. The aim is to determine simultaneously the optimal production schedule for two products and the optimal procurement policies for the raw materials in a way that minimizes the total variable cost of the production system. The production schedule for the more frequently set-up product is formulated by the method of equal or unequal lot sizes. For the model developed, we present a computational scheme of finding the optimal policies and carry out sensitivity analysis through example problem.

  • PDF

Application of Disaster Information Classification System for Disaster Management (시설물 재해관리를 위한 재해정보분류체계 구성 방안)

  • Kang Leen-Seok;Park Seo-Young;Moon Hyoun-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.335-342
    • /
    • 2006
  • Disaster management system should be built for minimizing damage factor that affects to construction facility from natural disaster. It could be classified by three categories such as disaster prevention, damage survey and recovery phases. For an integrated disaster management system, a disaster information classification system(DICS) is necessary for the reasonable disaster information management. This study suggests an integrated DICS that includes disaster type classification, facility type classification and information type classification for disaster management service. The applicability of suggested DICS is verified by railway facility and the research result could be used as a basic information system for national disaster management system.

Ontology-based Facility Maintenance Information Integration Model using IFC-based BIM data

  • Kim, Karam;Yu, Jungho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.280-283
    • /
    • 2015
  • Many construction projects have used the building information modeling (BIM) extensively considering data interoperability throughout the projects' lifecycles. However, the current approach, which is to collect the data required to support facility maintenance system (FMS) has a significant shortcoming in that there are various individual pieces of information to represent the performance of the facility and the condition of each of the elements of the facility. Since a heterogeneous external database could be used to manage a construction project, all of the conditions related to the building cannot be included in an integrated BIM-based building model for data exchange. In this paper, we proposed an ontology-based facility maintenance information model to integrate multiple, related pieces of information on the construction project using industry foundation classesbased (IFC-based) BIM data. The proposed process will enable the engineers who are responsible for facility management to use a BIM-based model directly in the FMS-based work process without having to do additional data input. The proposed process can help ensure that the management of FMS information is more accurate and reliable.

  • PDF

A Management of Child Care Facility for Electrical Safety using Home-Smart Cabinet Panel(H-SCP) (지능형 홈 분전반을 이용한 영유아 시설 전기 안전 관리)

  • Ahn, Jae-Min;Lim, Young-Bae;Bae, Seok-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2144-2145
    • /
    • 2011
  • We carry out a demonstration project to verify performance of a Home- Smart Cabinet Panel(H-SCP) at the child care facility. It is difficult to prevent an electrical disaster using a existing cabinet panel because electrical events are invisible and unforeseeable. So we construct a integrated information system with a Home-Smart Cabinet Panel(H-SCP) for management of low-voltage customers. The integrated information system with the H-SCP maintain the transmitted data from H-SCP, alert a electrical event to a administrator and show a state of customer health in real time respectively. A manager of electrical safety can prevent electrical disaster to maintain electrical facilities after analysis on the integrated information system.

  • PDF

A Demonstration Construction of Sewerage Underground Facilities Map Based on Aerial Photograph (항공사진 기반 하수 지하시설물도 시범구축)

  • Min, Kwan-Sik;Choi, Min-Ho
    • Spatial Information Research
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2011
  • This study attempts to establish sewerage underground facility map using aerial photograph with high readability and accessibility as an alternative of digital map and compilation cadastral map. A study on utility and consistency of established sewerage underground facility map in line with the current continuous cadastral map of underground facility was carried out. If underground facility map is established and utilized by converging digital image and compilation cadastral map, various spatial information analysis and systematic and integrated information utilization is available. The drawing of underground facility map using aerial photograph in this highly information-oriented society shall play a role in basic map for integrated control as an alternative of problems in the current drawing and designs created and managed by controlling institutions. In addition, the information of sewerage underground facility map using aerial photograph shall be used for establishing systematized urban planning and control.

An Integrated AHP-VIKOR Methodology for Facility Layout Design

  • Shokri, Hamidreza;Ashjari, Behzad;Saberi, Morteza;Yoon, Jin Hee
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.389-405
    • /
    • 2013
  • A facility layout design (FLD) problem can be generally introduced as assignment of facilities (departments) to a site such that a set of criteria are satisfied or some objectives are minimized (maximized). Hence, it can be considered as a multi-criteria problem due to the presence of qualitative criteria such as maintenance or flexibility and quantitative criteria such as the total cost of handling material. The VIKOR method was developed to solve multiple criteria decision making problems with conflicting and non-commensurable (different units) criteria, assuming that compromising is acceptable for conflict resolution, the decision maker wants a solution that is the closest to the ideal, and the alternatives are evaluated according to all established criteria. This paper proposes a hierarchical analytic hierarchy process (AHP) and VIKOR approach to solve the FLD problem. A computer-aided layout-planning tool is adopted to generate the facility layout problems, as well as their quantitative data. The qualitative performance measures are weighted by AHP. VIKOR is then used to solve the FLD problem. Finally, the proposed integrated procedure is applied to three real-time examples.

Strategy of Establishing GIS for Social Facility in Korea (한국의 사회기반시설물 GIS 구축 방안)

  • 이태식;이교선;조영준
    • Spatial Information Research
    • /
    • v.2 no.1
    • /
    • pp.27-38
    • /
    • 1994
  • Due to the rapid civilization, the need for social facilities is increasing. When these facilities controlled by the integrated facility management system (GIS), various adverse situations such as emergencies, inconvenience of the public and duplication of construction cost can be improved. In this study, the types of information for GIS which may be needed by the facility management agencies are investigated and analyzed. Based on this information, major components for the integrated facility management system including standard format of digital map, basemap scales, and basemap management methods are established.

  • PDF

Design and Implementation of facility Management System based Ubiquitous (u-기반 시설물 관리 시스템 설계 및 구현)

  • Kim, Jung Jae;Park, Chan Kil
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • The USN is important in technique, unmanned observation using wireless network camera, detection technique that use intrusion detection sensor. But these encrypted data transmission and processing technique through sensor network, method of the staff's location recognition and arrangement aren't serviced still as a integrated system in facility security industry. This paper proposed that improve facility management, the staff present recognition and system efficiency using RFID, USN and wireless camera.

A Study for Development of Facility Management System Using GIS (GIS를 이용한 시설물관리시스템 개발에 관한 연구 - 강원대학교를 중심으로-)

  • Yang, In-Tae;Yu, Young-Geol;Chun, Ki-Sun;Park, Jai-Kook
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.101-107
    • /
    • 2003
  • In university of Korea, the computerization of facility management is lower level than other management areas such as educational matters, administration, library, computing center, teaching assistance, and teaching methodology. So we need urgently the blueprint for an information-oriented and integrated facility management system. In this research, It is presented and implemented an FMS(Facility Management System) for efficient management of the ground and underground facilities on a campus. This studies is computerized the drawings, protocols, and ledgers. It is used a GIS(Geographic Information System) to get the geographical information of facilities. The data more efficiently could be search and update on this system. The decision making process understanding the present facility condition, and analyzing the condition of location could be performed easily by the GUI(Graphic User Interface) of the system.

  • PDF