• Title/Summary/Keyword: insulations

Search Result 118, Processing Time 0.027 seconds

An Efficient Vibration Analysis of the Floors in Residential Building (주거용 건축물의 효율적인 바닥진동해석)

  • Kim, Tae-Ho;Lee, Dong-Guen
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.228-235
    • /
    • 2005
  • The floor impact sound insulations are installed frequently for reducing the floor impact sound into the floor slab of the residential buildings in recent years. Therefore the analytical FE model considering the insulations is needed for the sound and vibration analysis of the floor and it is necessary to use a refined finite element model for considering the large number of modes involving in the dynamic responses. So it is very difficult to use FE model because of the tiresome task for constructing the FE model, taking a lot of times for analysis and the impossibility of using the proportional damping. The efficient analysis and modeling method are proposed to the dynamic analysis for the floor with floor impact sound insulations in this study. The floor slabs and finished layers are modeled individually and the spring elements that mean floor impact sound insulations use to connect two parts. The dynamic analysis by the $Newmark-{\beta}$ method is performed to solve the non-proportional damping problem due to the damping coefficient of insulations .

  • PDF

Electrical Characteristics Assessment for PE Series Insulations (PE 계열 절연재 전기적 특성 평가)

  • Jung, Jong-Wook;Jung, Jin-Soo;Han, Woon-Ki
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.430-435
    • /
    • 2007
  • This paper describes the results of electrical characteristics assessment for organic insulations of polyethylene(PE) series insulations and acrylonitrile butadiene styrene copolymer(ABS). In the experiment, 4 kinds of specimens by composition density were tested in relative permittivity, specific resistance and tracking duration. A WinDETA system and a tracking test set manufactured for this assessment were used to measure the dielectric parameters and tracking duration, respectively. In measuring the tracking duration, the time from testing voltage application to testing circuit breaking due to the tracking current was measured. As a result, dielectric dispersion was observed in measuring the relative permittivity of ABS. It was confirmed that the relative permittivity decreased with the density of the PE series insulations and it depends rather on the temperature than frequency. In most specimens, specific resistance exponentially decreased with frequency and the result for each specimen was almost similar. By the way, in the tracking test, all the PE series insulations showed more excellent performance than ABS and especially in the case of HDPE, its tracking withstand performance was the best.

Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer (고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

Degradation Diagnosis of Insulation Paper Using CO and $CO_2$ Gases in Oil Immersed Transformers (CO와 $CO_2$ 가스를 이용한 유입식 변압기 절연지의 열화진단에 관한 연구)

  • Sun Jong-Ho;Yi Sang-Hwa;Kim Kwang-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.523-529
    • /
    • 2004
  • Faults of cellulosic insulations greatly affect the life span of oil immersed transformers because their performance recovery is impossible. Therefore, the reliable diagnosis technologies are needed for detection of the faults. Dissolved gas analysis technologies using CO and $CO_2$ gases have been widely used for fault diagnosis of cellulosic insulations. In this research, we described Degradation diagnosis of insulation paper CO and $CO_2$ gases in oil immersed Transformers using. We considered the distribution characteristics of CO, $CO_2$ gases' concentrations and ratios of $CO_2$/CO not only in serviced transformers but in experiments with typical fault causes such as heat, partial discharge and moisture. As result, the reliability of diagnosis results for the cellulosic insulations can be improved when the concentrations of CO, $CO_2$ and the ratio of CO/$CO_2$ satisfy each diagnosis criterion at a tim

Microstructure Analysis of Large Turbine Generator Stator Insulations (대형 터빈발전기 고정자 권선의 미세구조 분석)

  • Kim, Hee-Dong;Ju, Young-Ho;Song, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1452-1454
    • /
    • 2002
  • Large turbine generator(rated 22kV) has failed in the stator winding area during normal operation. The capacitance and tan${\delta}$ were measured by Schering bridge in the zone 1, 2 and zone 3-6 stator windings. The capacitance and tan${\delta}$ in the zone 1, 2 of stator winding were higher than those of zone 3-6 in the stator winding. Experiments on microstructure property were conducted in the zone 1, 2 and zone 3-6 insulations, which were drawn out from stator windings of the large turbine generator. Microstructure analysis was characterized using scanning electron microscope(SEM). SEM results indicated that several isolated delaminations occurred at the interface of mica/epoxy insulations. Both thermal and mechanical aging cause the delamination.

  • PDF

Chemical Characteristics of Transformer Insulations by the Thermal Aging (변압기 절연물의 열화에 따른 화화적 특성)

  • Kim, Jae-Hoon;Lee, Won-Young;Lee, Byung-Sung;Lee, Sei-Hyun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1912-1914
    • /
    • 2005
  • The electrical, chemical and mechanical characteristics in transformer insulations are changed due to thermal stress. It is known that characteristics of transformer insulations is deteriorated such as decrease of dielectric strength, deterioration of dielectric constant and tensile strength of paper as transformer oil and paper are aged by thermal stress. Furthermore, chemical characteristics of them are deteriorated as like increment of moisture contents and dissolved by-products in oil, etc. In this paper we have been investigated chemical characteristics of transformer by accelerated thermal aging. For this working we have made experimental test cell and aged at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used Karl-Fisher titration method and high performance liquid chromatography (HPLC).

  • PDF

The Effect of Hydrogen Pressure on Partial Discharge Spectroscopy in Turbine Generator Winding Insulations (화력 발전기 고정자 권선에서의 수소 압력에 따른 부분 방전 특성)

  • Kim, Jin-Bong;Hwang, Don-Ha;Kim, Yong-Joo;Park, Myong-Soo;Kim, Taek-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1320-1325
    • /
    • 1995
  • For hydrogen-cooled large turbine generators, partial discharges in ground wall insulations are suppressed by high hydrogen pressure. The first goal of the experiment is to investigate the effect of hydrogen pressure on partial discharge activity and aging rate in turbine generator winding insulations. A series of tests have been performed on two groups of the accelerated aging experiments. The first group of stator windings was aged under hydrogen pressure of 4 atm while the second group of stator windings was aged under air atmosphere. The stator windings aged under air atmosphere suffer from larger partial discharge magnitude with larger voids at high electrical stress than those under hydrogen pressure. The second goal of the experiment is to evaluate the validity of on-line measurement technique which is normally measured under hydrogen environment. The test results show that further experiments are needed to apply the on-line scheme to turbine generator being under high hydrogen pressure.

  • PDF

Thermal Analysis of a Liquid Hydrogen Vessel with Multi-Layer-Insulation and Vapor-Cooled Shield (다층단열재와 증기냉각쉴드를 사용한 액체수소 저장용기의 열해석)

  • Jung, Il-Kwon;Kang, Byung-Ha
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.3
    • /
    • pp.284-289
    • /
    • 2005
  • Thermal analysis of cryogenic-capable vessels with insulations have been carried out to store liquid hydrogen($LH_2$). The combined insulations of MLI(Multi-Layer Insulation) and VCS(Vapor-Cooled Shield) under high vacuum are considered in the analysis for various volumes of vessels. Vapor-Cooled Shields(VCS) are installed at cylinder wall as well as disc side of the $LH_2$ vessels. The results indicate that optimal distribution of boiloff vapor from $LH_2$ vessel into two sides of VCS exists based on the evaporation loss. As the volume of $LH_2$ vessel is increased, mass flow rate of boiloff is increased while the evaporation loss per unit volume is decreased.

The Effect of Pressurized Hydrogen on the Aging and Partial Discharge Activity in Generator Winding Insulations (가압 수소가 발전기 고정자 권선 절연 열화와 부분 방전 특성에 미치는 영향)

  • 김진봉
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.100-107
    • /
    • 1999
  • The purpose of the study is to investigate the effect of H$_2$ pressure on partial discharge (PD) activity and aging rate in turbine generator winding insulations. A series of field tests and laboratory tests were peformed to investigate the effect of $H_2$ pressure on PD activity. Field tests were conducted at two unit turbine generators in two conditions, in $H_2$ pressure and in air atmosphere. Obtained results are as follows ; 1) ${\Delta}tan{\delta}$ and maximum partial discharge are reduced with increase of $H_2$ pressure and partial discharge inception voltage. 2) The reduction ratio of ${\Delta}tan{\delta}$ due to $H_2$ pressure is higher than one of PD magnitude. 3) Partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. From the result, partial discharge pulses are subjected to resonance phenomena in a generator winding.

  • PDF

A Tracking Test for PE Series Insulations (PE 계열 절연재의 내트래킹 성능 평가)

  • Jung, Jong-Wook;Jung, Jin-Soo;Yi, Geon-Ho;Park, Ha-Yong;Kim, Nam-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.154-155
    • /
    • 2006
  • This paper describes a tracking test results for the organic polymers with PE(polyethylene) series by a declining method. After processing the 4 PE series insulations with different density, the tracking duration for each was measured and compared with that for ABS(acrylonitrile butadiene styrene). The surface condition of each specimen was carefully observed after the tracking test. As a result, HDPE showed excellent performance in tracking test.

  • PDF