• 제목/요약/키워드: insulation oil

검색결과 258건 처리시간 0.025초

불평등 전계에서 변압기 절연유 절연파괴 연구 (Study on the Breakdown of the Transformer Insulating Oil in Nonuniform Electric Field)

  • 조하영;이순형;황미용;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.280-285
    • /
    • 2023
  • A breakdown voltage and breakdown electric field of the transformer insulating oil of liquid dielectric were studied in uniform electric field and non-uniform electric field and the transformer insulating oil was observed by the process reached breakdown. Insulation performance evaluation of the liquid dielectric was evaluated at the electrode spacing of 2.5 mm under the conditions of domestic and international standards (KS C IEC 60156), so a comparative review was conducted at the electrode spacing of 2.5 mm. When the electrode spacing is 2.5 mm, the average breakdown voltage is 38.5 kV for sphere-sphere electrodes, 26.6 kV for plate-plate electrodes, 22.9 kV for needle-needle electrodes, and 24.3 kV for sphere-needle electrodes. 23.7 kV for the sphere-plate electrode, and 20.7 kV for the needle-plate electrode. From these results, it can be seen that the average value of the breakdown voltage at the electrode spacing of 2.5 mm, in ascending order, is sphere-sphere, plate-plate, sphere-needle, sphere-plate, needle-needle and needle-plate. It was found that the breakdown voltage of the unequal field was lower than that of the equal field.

Modelling of On-Site Energy Consumption Profile in Construction Sites and a Case Study of Earth Moving

  • Yi, Kyoo-Jin
    • Journal of Construction Engineering and Project Management
    • /
    • 제3권3호
    • /
    • pp.10-16
    • /
    • 2013
  • The annual expenditure on diesel oil and heavy oil in the construction sector is the second largest among all industrial sectors. According to the greenhouse reduction scheme of Korean Government, construction sector targeted 7.1% reduction by 2020. Although this target is not higher than other industrial sectors, it is not easy to achieve the reduction target without radical advance in technology, which cannot be expected to happen soon, considering the conservative characteristics of construction industry. Most researches on environmental issues focus on the issues related to energy saving matters during material production stage or maintenance stage, such as heating and insulation, and few deal with the issues directly related to the energy use in the construction sites. This research regards the operation of equipment for the on-site construction processes as a system and attempts to model the energy use processes related to the activities in construction sites, and provides simulation results of earth excavation and hauling processes. The result of this research is expected to aid construction planners estimating the time-based patterns of energy use and assessing greenhouse gas emission and to help selecting more energy efficient alternatives at the planning stage.

셀룰로오스 절연지의 열화온도에 따른 절연특성 및 통계처리에 의한 상관관계 규명 (Estimating for Properties of Insulating Degradation for Cellulose paper with Aging Temperature and Correlation by Statistical Treatment)

  • 김재훈;김대식;한상옥
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.912-917
    • /
    • 2010
  • It was known that oil-filled transformer's life depended on insulating paper which was applied to transformers for insulating of transformer. Therefore when paper was aged, its electrical, mechanical and chemical characteristics were changed. Especially if operating temperature was high, paper was quickly damaged. As cellulose paper which was mainly used for solid insulation of transformers was degraded, the cellulose polymer chains broke down into shorter lengths and gases such as CO, $CO_2$, $CH_4$, $C_2H_4$ and so on were produced from paper. Also by-product known as furan compounds were producted from paper and it were dissolved within insulating oil. In this paper accelerating aging cell was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, so evaluating the chemical characteristics of cellulose paper by thermal. An it were performed analysis such as tensile strength(TS), dissolved gas analysis(DGA) and high performance liquid chromatography(HPLC). Also for analyzing of correlation between insulating degradation characteristics, it was performed linear regression method as statistical treatment.

가교폴리에틸렌 계면에서의 트리성장 분석 (An Analysis of Tree Growth in the XLPE Interface)

  • 김철운;박현빈;김태성;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.90-94
    • /
    • 1998
  • This study aims at analyzing to treeing in the solid-solid interface which is insulation type of cable junction parts, the proceeding of tree-growth and electrical breakdown were research in the study. Interface was made artificially to detect how it influenced the insulating ability of the whole system, the specimen were XLPE generally used in cable. The interface conditions were divided into two parts. First condition being the one focused on the surface of interface, it was treated with sand paper (#80, #600, #1200). For the second condition, the pressure of interface was varied as the value of 1, 5, 10 [$kg/cm^2$]. Using above conditions, treeing and breakdown properties on tree-growth were respectively compared in details. As a result, breakdown time was shorter for the full range of supplied voltage in the case of interface existed in the joint than non-existed interface. In the case of existed interface, the interface which had high-interface pressure and painted with silicon insulating oil was the best in the aspect of breakdown characteristics.

  • PDF

고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험 (Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

덕 다운의 악취 냄새물질 제거를 위한 항균소취 가공 (Antibacterial and Deodorant Processing to Remove Odor Substances from Duck Down)

  • 이범훈;조항성
    • 한국염색가공학회지
    • /
    • 제32권4호
    • /
    • pp.232-238
    • /
    • 2020
  • Duck down is a feather of waterfowl and is used as an accessory for bedding products such as evil, pillow and outdoor sleeping bags due to its soft and bulky characteristics. Down is used mainly for winter outdoor such as padding and jumpers because of its excellent thermal insulation effect. Down wear is known as a product with high added value. Down is processed and sanitized because a large amount of oil and fat, bacteria, dust, insects, and soil are mixed. In particular, if the proper amount of oil and fat is not removed, it may cause odor or bacteria, and since the fishy smell peculiar to down and harmful VOCs (toluene, benzene, etc.) are released, there is a need to suppress the occurrence of bacteria through the provision of antibacterial function. In this study, we investigated the substances that cause the fishy odor of down, and confirmed the effect on the deodorization and antibacterial properties of down according to processing agents and processing conditions in order to impart deodorant and antibacterial properties to down.

SYSTEM MODELLING OF ON-SITE ENERGY CONSUMPTION PROFILE IN CONSTRUCTION SITES AND A CASE STUDY OF EARTH MOVING

  • Kyoo-Jin Yi
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.287-293
    • /
    • 2013
  • The annual expenditure on diesel oil and heavy oil in the construction sector is the second largest among all industrial sectors. According to the greenhouse reduction scheme of Korean Government, construction sector targeted 7.1% reduction by 2020. Although this target is not higher than other industrial sectors, it is not easy to achieve the reduction target without radical advance in technology, which cannot be expected to happen soon, considering the conservative characteristics of construction industry. Most researches on environmental issues focus on the issues related to energy saving matters during material production stage or maintenance stage, such as heating and insulation, and few deal with the issues directly related to the energy use in the construction sites. This research regards the operation of equipment for the on-site construction processes as a system and attempts to model the energy use processes related to the activities in construction sites, and provides simulation results of earth excavation and hauling processes. The result of this research is expected to aid construction planners estimating the time-based patterns of energy use and assessing greenhouse gas emission and to help selecting more energy efficient alternatives at the planning stage.

  • PDF

펄스형 고전압 측정용 용량성 분압기 (Capacitive Voltage Divide for a Pulsed High-Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.

변압기 폭발/화재 방지 기술 (TRANSFORMER EXPLOSION AND FIRE PREVENTION)

  • 김형승;필리프매그너
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가 (Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable)

  • 곽병섭;전태현;김아름;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.263-273
    • /
    • 2019
  • OF 케이블의 예상 설계 수명인 30년이 도달하면서 고장 위험성이 증가하고 있다. 따라서 정확한 진단을 통한 열화 판정으로 장기 운용 OF 케이블을 적기에 진단함으로써 고장을 예방해야 한다. 또한 최적의 진단기준을 제시하여 잔류 수명을 예측하고 적절한 시기에 교체하는 조치가 요구되고 있다. 현재 한국전력공사에서는 OF 케이블을 진단하기 위해서 주기적으로 케이블 유중 가스분석을 실시하여 C2H2, TCG 등 일부 가스만 활용하고 있다. 하지만 이러한 유중 가스분석에서 확인되는 가스는 절연지뿐만 아니라 오일의 열화에 의해서도 발생된다. OF 케이블은 해체점검이 불가하기 때문에 절연지의 수명이 OF 케이블의 수명으로 간주되고 있다. 따라서 절연지를 직접적으로 분석하는 절연지 중합도 평가와 절연유중 퓨란화합물을 분석이 필요하며, 유중 가스분석에서 확인되는 CO, H2, CH4, C2H4, C2H6, C2H2 가스와 상관관계를 확인할 필요가 있다. 따라서 본 연구에서는 절연유중 가스를 분석하기 위해 headspace sampler가 장착된 GC를 사용하였고, 절연지 중합도는 자동점도계를 활용하였으며, 절연유중 퓨란화합물은 HPLC를 이용하여 측정하였다. 또한 OF 케이블의 종합적인 판정을 위하여 국내 OF 케이블 중 15개소를 선정하여 해체점검을 수행하였다. 또한 이렇게 얻어진 결과는 최근 전력설비 이상판정에 도입되고 있는 SVM 기법에 적용하여 정확하고 신뢰성 있는 열화판정을 도출하고자 하였다. 그 결과 절연지 중합도 잔률은 CO와 CO2 농도의 합에 따라 음의 2차 함수 관계로 감소하는 것으로 확인되었다. 또한 본 연구에서 얻어진 한전 OF 케이블 진단결과를 SVM 기법에 적용함으로써 한전 OF 케이블 진단결과를 기존 일본 동경전력의 SVM에 적용한 진단결과보다 향상되었고, 그 정확도는 약 87.9% 인 것으로 확인되었다.