• 제목/요약/키워드: insulation deterioration

검색결과 170건 처리시간 0.028초

수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 변일환;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

대용량 수차발전기의 절연진단과 절연보수 상관관계 평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 오봉근;정진달;이광호;김현일;곽희진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.39-41
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator #2 which had been in service after being constructed 1980. After repair of the stator winding insulation, we conducted insulation diagnostic tests which include resistance, polarization index(P.I), AC current, dissipation factor($Tan\delta$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results, this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

단열성 단면복구 Mortar의 내구성에 관한 연구 (A Study on the Durability of Restorative Cement Mortar with Insulation Performance)

  • 나승현;김형진;서병돌;강현주;송명신
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.495-496
    • /
    • 2009
  • 콘크리트는 항온에서보다 온도의 편차가 클수록 열화가 빠르게 진행되기 때문에 열화된 콘크리트의 물성을 복구하기 위하여 사용되는 단면복구재는 외부 온도 변화에 의한 단면복구재의 품질 변화가 적거나 단면복구재에 의해 복구된 열화 콘크리트의 안정화를 유지할 수 있는 품질을 확보해야 할 필요가 있다. 본 연구에서는 일반적인 단면복구 mortar에 단열성능을 부여하여 열화 콘크리트 보수용 재료로서의 내구성능 변화에 대해 연구하였다.

  • PDF

건축 구조물 외단열 시스템의 열화 및 누수현상이 구조물 노후화에 미치는 영향 분석에 관한 연구 - 초고층 oo 아파트 외벽 누수 사례를 통하여 - (Analysis the influence of the exterior insulation deterioration and water leakage on the aging of concrete structure)

  • 박연진;박진상;선윤숙;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.159-163
    • /
    • 2007
  • We studied the example of various side on effect the aging of exterior materials for concrete structure by analyzing the reason of water leakage in exist serviced skyscraper apartment. For this side, we would like to suggest the proper waterproofing materials and construction methods resulted in the mechanical performance test. So, it could be ensured the leakage safety for using residence facility and crowd utilization after repairing. It may maximize the durability for the concrete structure.

  • PDF

전동차의 리액터 코일의 절연물 열화 모니터링 시스템 구축 (Insulation deterioration monitorring system construction of reactor coil of the rolling stocks)

  • 안종곤;김동민;황남훈;박순명;원봉의
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.900-907
    • /
    • 2008
  • All electric trains in the city should be run without any troubles of the equipments in order to offer good services to the passengers. But some breakdowns occur when they are operated due to the long time uses. There are mechanical troubles and electrical troubles included reactors. Most of them, the reason of the troubles can be found out easily after breakdown. But it is difficult to find out the reasons of the reactor troubles which disappear after operation. The reactors of the train filter the current which supplied from electrical lines and supply the current to the inverter and block the ripple of the current. Partial discharge occur from the reactor by the heat. accordingly, If the signals of discharge were perceived, it could be anticipate the deterioration degree of insulation. In this paper, on-monitoring system for reactor's troubles in trains is established and the output results of monitoring system are investigated.

  • PDF

6.6kV CV케이블의 경년열화 특성연구 (A study on the characteristics of deterioration in 6.6kV CV cable)

  • 김광화;선종호;김영배;조연옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF

절연물의 열화에 의한 AE신호와 변압기 외함의 AE노이즈 분포 (Distribution Characteristics of AE Signals in Insulation Deterioration and AE Noise in Cast Resin transformer)

  • 이상우;김인식;김이국;박원주;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2002
  • In this paper, frequency spectra of AE signals detected from respective the insulation deterioration were analysed to under ac high-voltage application using epoxy resin sample and insulation oil. Also, frequency spectra of AE signals generated from the load currents in the actual operating transformer of 500[kVA] under distribution system of 22.9[kVJ] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals.

  • PDF

전기기기용 비닐절연전선에서의 직렬 아크에 의한 열화 특성 분석 (Analysis of Deterioration Characteristics of Polyvinyl Chloride Insulation Wires for Electrical Apparatus by Series Arcing)

  • 김향곤;길형준;김동욱;김동우;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, we experimented deterioration characteristics of PVC insulation wires for electrical apparatus by series arcing and analyzed the heat generation at the contacts of wires, glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation, and so on. We found out that how glowing contacts and surface arcing can decompose PVC insulation and that subsequent series arc can lead to ignition. We expect that these results are useful for improving fire protection technology by providing a better understanding of how electrical fires can initiate.

  • PDF

발전소 고압전동기 열화 요인 분석 (A Survey of Deterioration Causes of High Voltage Motors in Power Plants)

  • 김경열;김희동;김병래;공태식;김병한;이상길;이종훤;최홍석
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.807-811
    • /
    • 2011
  • When the high voltage motor fails in power plants, there will be an occurrence where the generator's output would be reduced or the generators would trip. Despite of these effects, the causes of deterioration of the high voltage motor is very seldom investigated. In this paper, the collected data which tested in the field over 10 years have been treated statistically, and analyzed to correlate the insulation deterioration of high voltage motor and installation environment, number of start/stop, and service life. Moreover, the proper period of insulation test is developed to map out maintenance strategy and reduce maintenance costs.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.