• 제목/요약/키워드: insulation design

검색결과 900건 처리시간 0.031초

6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계 (The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings)

  • 임광진;박노준;김희동;주영호;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제21권5호
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용 (Development and application of on-line lightning information service)

  • 곽주식;우정욱;강연욱;구교선;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF

A Numerical Approach for Lightning Impulse Flashover Voltage Prediction of Typical Air Gaps

  • Qiu, Zhibin;Ruan, Jiangjun;Huang, Congpeng;Xu, Wenjie;Huang, Daochun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1326-1336
    • /
    • 2018
  • This paper proposes a numerical approach to predict the critical flashover voltages of air gaps under lightning impulses. For an air gap, the impulse voltage waveform features and electric field features are defined to characterize its energy storage status before the initiation of breakdown. These features are taken as the input parameters of the predictive model established by support vector machine (SVM). Given an applied voltage range, the golden section search method is used to compute the prediction results efficiently. This method was applied to predict the critical flashover voltages of rod-rod, rod-plane and sphere-plane gaps over a wide range of gap lengths and impulse voltage waveshapes. The predicted results coincide well with the experimental data, with the same trends and acceptable errors. The mean absolute percentage errors of 6 groups of test samples are within 4.6%, which demonstrates the validity and accuracy of the predictive model. This method provides an effectual way to obtain the critical flashover voltage and might be helpful to estimate the safe clearances of air gaps for insulation design.

NCT 설계 및 특성 분석에 관한 연구 (A Study on the Design and Chracteristic Analysis for Noise Cut Transformer)

  • 이재복;허창수
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.146-154
    • /
    • 1998
  • 교류 전원선로에서 발생하는 수 kHz에서 수십 MHz에 이르는 광대역의 주파수특성올 가진 전원노이즈는 전기, 전자장비의 정상적인 동작에 많은 장해요소가 되고 있으며 이들 전도노이즈를 억제하기 위한 부품으로 현재 써어지 억제부품과 필터가 적용되고 있다. 그러나 기존의 대책부품은 전력공급선과 노이즈 피해회로를 전기적으로 완전히 절연시킬 수 없기 때문에 전도 노이즈 중에서 가장 크게 발생하는 공통모드 노이즈 억제성능이 제한 되고 있다. 본 논문에서는 절연변압기의 절연 특성에 정전 차폐를 추가함으로써 전도노이즈 및 써어지 억제기능이 우수한 NCf의 설계방법올 제시하였으며, 설계 제작된 1[kVA] NCT 시작품의 모의 등가회로에 대한 써어지 해석결과와 실험 측정 결과를 상호 비교하여 제안된 모델의 특성을 비교 평가하였다.

  • PDF

6배압 정류기를 이용한 고전압 전원장치에 관한 연구 (A Study of the High Voltage Power Supply using a Sixfold Voltage-Multiplying Rectifier)

  • 안태영;길용만
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.19-26
    • /
    • 2015
  • This paper presents design, fabrication, and performance evaluation of a high voltage power supply for Carbon Nano Tube-based planar light sources. The proposed power supply employs an LLC resonant half-bridge converter and a sixfold voltage-multiplying rectifier. Steady-state characteristics of the voltage-multiplying rectifier are analyzed and used to derive the input-to-output voltage conversion ratio of the power supply. The input-to-output frequency response characteristics of the LLC tank circuit are analyzed and utilized in designing a proto-type power supply which produces a 15 KV output using a 400 V input source. The high-voltage transformer is fabricated using a sectional bobbin structure with an epoxy impregnation, in order to provide sufficient insulation for high voltage operations. The performance of the proposed power supply is confirmed with stable and reliable operations at the 15 KV output from no load to nominal load conditions. The proposed power supply is well suited as an electric ballast required stable operations of Carbon Nano Tube-based planar light sources.

국가기간시설물의 전식대책(안) 및 그 적용 사례(1) (A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

전기 트리를 가지는 사각 버스바의 절연 설계에 관한 유한요소해석 (Finite Element Analysis for Insulation Design of Rectangular Busbar with the Electrical Tree)

  • 전준영;노태우;조성만;김상민;오종석;최정완;서재학
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.205-206
    • /
    • 2015
  • 케이블 및 버스바는 전원을 공급하는 부대 장치로 산업 전반에 걸쳐 널리 사용되고 있다. 대부분의 경우 일정 주기로 점검 및 교체 등의 유지 보수를 진행하나 ITER IVC 버스바 및 지중케이블 등의 특수한 경우에서는 접근성 및 작업성의 이유로 유지 보수를 진행 할 수 없다. 이러한 경우, 절연물 내부에 전기 트리가 발생했을 때에는 대책이 없다. 전기 트리는 부분적인 고전계에 의한 진성파괴, 전하의 주입 또는 추출에 의한 파괴 및 전기-기계적 응력(맥스웰 응력)에 의한 파괴, 미소 부분 방전에 의한 파괴의 가장 큰 고장요인이 되는 현상이며, 다양한 사고 사례가 알려져 있다. 본 연구에서는 유한요소해석법을 이용하여 전기 트리를 가지는 사각 버스바에 대한 전계해석을 진행하였고, 전기 트리를 방지 할 수 있는 사각 버스바의 절연 설계에 대한 방안을 제시한다. 이 설계 방안은 향후 전기 트리를 고려한 사각 버스바의 절연 설계 기초 데이터로 활용 될 것이다.

  • PDF

고압용기의 계장선 통과부위 밀봉기술 개발 (Development of Sealing Technology for Instrumentation Feedthrough of High Pressure Vessel)

  • 정황영;홍진태;안성호;정창용;이종민;이철용
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.137-143
    • /
    • 2011
  • Fuel Test Loop(FTL) is a facility which could conduct a fuel irradiation test at HANARO(High-flux Advanced Neutron Application Reactor). FTL simulates commercial NPP's operating conditions such as the pressure, temperature and neutron flux levels to conduct the irradiation and thermo-hydraulic tests. The In-Pile Test Section(IPS) installed in HANARO FTL is designed as a pressure vessel design conditions of $350^{\circ}C$, 17.5MPa. The instrumentation MI-cables for thermocouples, SPND and LVDT are passed through the sealing plug, which is in the pressure boundary region and is a part of instrumentation feedthrough of MI-cable. In this study, the brazing method and performance test results are introduced to the sealing plug with BNi-2 filler metal, which is selected with consideration of the compatibility for the coolant. The performance was verified through the insulation resistance test, hydrostatic test, and helium leak test.

Unconfined compressive strength property and its mechanism of construction waste stabilized lightweight soil

  • Zhao, Xiaoqing;Zhao, Gui;Li, Jiawei;Zhang, Peng
    • Geomechanics and Engineering
    • /
    • 제19권4호
    • /
    • pp.307-314
    • /
    • 2019
  • Light construction waste (LCW) particles are pieces of light concrete or insulation wall with light quality and certain strength, containing rich isolated and disconnected pores. Mixing LCW particles with soil can be one of the alternative lightweight soils. It can lighten and stabilize the deep-thick soft soil in-situ. In this study, the unconfined compressive strength (UCS) and its mechanism of Construction Waste Stabilized Lightweight Soil (CWSLS) are investigated. According to the prescription design, totally 35 sets of specimens are tested for the index of dry density (DD) and unconfined compressive strength (UCS). The results show that the DD of CWSLS is mainly affected by LCW content, and it decreases obviously with the increase of LCW content, while increases slightly with the increase of cement content. The UCS of CWSLS first increases and then decreases with the increase of LCW content, existing a peak value. The UCS increases linearly with the increase of cement content, while the strength growth rate is dramatically affected by the different LCW contents. The UCS of CWSLS mainly comes from the skeleton impaction of LCW particles and the gelation of soil-cement composite slurry. According to the distribution of LCW particles and soil-cement composite slurry, CWSLS specimens are divided into three structures: "suspend-dense" structure, "framework-dense" structure and "framework-pore" structure.

Acoustical characteristic predictions of a multi-layer system of a submerged vehicle hull mounted sonar simplified to an infinite planar model

  • Kim, Sung-Hee;Hong, Suk-Yoon;Song, Jee-Hun;Kil, Hyun-Gwon;Jeon, Jae-Jin;Seo, Young-Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권2호
    • /
    • pp.96-111
    • /
    • 2012
  • Hull Mounted Sonar (HMS) is a long range submerged vehicle's hull-mounted passive sonar system which detects low-frequency noise caused by machineries of enemy ships or submerged vehicles. The HMS needs a sound absorption /insulation multi-layer structure to shut out the self-noise from own machineries and to amplify signals from outside. Therefore, acoustic analysis of the multi-layer system should be performed when the HMS is designed. This paper simplified the HMS multi-layer system to be an infinite planar multi-layer model. Also, main excitations that influence the HMS were classified into mechanical, plane wave and turbulent flow excitation, and the investigations for each excitation were performed for various models. Stiffened multi-layer analysis for mechanical excitation and general multi-layer analysis for turbulent flow excitation were developed. The infinite planar multi-layer analysis was expected to be more useful for preliminary design stage of HMS system than the infinite cylindrical model because of short analysis time and easiness of parameter study.