• 제목/요약/키워드: insulation characteristic

검색결과 283건 처리시간 0.031초

배전용 절연카바류의 경년특성 분석 (The Analysis of Ageing Characteristics of Insulation Cover Using in Distribution Line)

  • 김동명;송일근;한재홍;이병성;한용회;이태선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.76-78
    • /
    • 2001
  • In this paper insulation cover that being used in distribution line have been evaluated for aging characteristics. For evaluating its aging properties, we dismounted a variety of samples, like insulation covers for termination of deadend clamp, bushing, LA, COS and sleeve, in the fields. we performed mechanical properties test, electrical test, weathering test, etc. of these samples. And these samples are compared with virgin sample. Test results shows the bad mechanical strength in some part of samples. Especially, Insulation covers for the bushing terminations have cracks in the surface of samples.

  • PDF

변압기용 차음판의 진동 및 소음 특성 (Characteristic of Vibration and Sound of Sound Insulation Panel for Transformer)

  • 최창림;최병근;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.255-258
    • /
    • 2005
  • Recently, demands for the reduction of noise generated by transformers have been increasing. Almost all the noise generated by a transformer is a result of magnetostrictive vibration in the core. The noise radiates into the atmosphere from the tank through the insulation oil. One method of reduction such a noise is to build a free-standing enclosure of concrete and steel plates around the transformer. However, this method has some disadvantages, for example, a large area is needed for equipment installation. In this paper, the vibration and noise effects which is transferred from reinforce channel to insulation panel generated by transformer have been identified for the several kinds of insulation panel shape and damping sheet experimentally.

  • PDF

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.

공동주택 층간단열 완충재의 열에너지 특성의 관한 연구 (A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House)

  • 최동혁;최경석;강재식;이승언;조우진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

다양한 파우더 충전 단열 방법의 단열 성능에 대한 실험적 연구 (Experimental research about thermal insulation performance of various powder insulation methods)

  • 김희선;정상권;정성하
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.49-54
    • /
    • 2010
  • This paper presents apparent thermal conductivity of various powder at different vacuum levels for cryogenic insulation. Four kinds of powder insulator are examined by using boil-off calorimetry at pressure range from 50 Torr to 3 mTorr. The first material is perlite which is widely used in cryogenic application. Microsphere is the second one that is recently proposed as a replacement powder for liquid hydrogen storage tanks. It is a hollow sphere made of silica with the diameter in the order of 10 to $100{\mu}m$. Popped rice and polystyrene beads are also selected as candidates for powder insulation even though they are polymers. With their porous elliptic and spherical configuration and light density, they demonstrate fairly good thermal insulation performance at pressure range from 50 Torr to 3 mTorr. According to the experimental investigation in this paper, microsphere and polystyrene beads possess promising insulation characteristic as powder insulators and further study is desired.

다공성 단열재를 포함한 열방어구조의 열 특성 분석 (Thermal Characteristic Analysis of Thermal Protection System with Porous Insulation)

  • 황경민;김용하;이정진;박정선
    • 항공우주시스템공학회지
    • /
    • 제10권4호
    • /
    • pp.26-34
    • /
    • 2016
  • 본 논문에서는 다공성 단열재의 정확도가 높은 유효 열전도율 예측 모델을 새롭게 제안하고, 기존 예측 모델 및 시험 결과와 비교 검증하였다. 이를 위해 기존 유효 예측 모델들을 다공성 단열재의 고체 부피율에 따른 열전도율 시험 결과 값과 비교하였다. 그리고 고체의 부피율에 따른 유효 열전도율 시험결과와 비교하여 가장 높은 정확도를 가진 Zehner-Schlunder 모델 및 시험 결과 데이터를 기반으로 고체-유체의 부피율과 열전도율 비로 구성된 다항식을 추가하여, 새로운 유효 열전도율 예측 모델을 정의하였다. 예측 모델을 시험 결과와 비교하여 검증하였다. 또한 예측 모델을 적용하여 열방어구조의 과도 열전달 해석을 수행하였으며, 열전달 시험 결과와의 비교를 통해 유효 열전도율 예측 모델의 유효성을 확인하였다.

파괴 및 비파괴진단 비교분석을 통한 케이블 열화특성평가 (Insulation Aging Characteristic Assessment on the Power cables with the Comparative Analysis Between Destructive and Nondestructive Diagnosis)

  • 이동영
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.104-108
    • /
    • 2009
  • 본 논문에서는 지중전력케이블을 대상으로 케이블의 절연열화특성 분석시험을 통해 케이블의 절연열화와 절연 진단결과 및 파괴강도와의 상관관계에 대한 실증연구를 수행하였다. 시험대상 선로의 제조결함 여부를 확인하기 위해 가교도분석, 핫오일테스트 등을 실시한 결과 제조결함은 없는 것으로 확인되었다. 진단대상 선로는 3상 모두 장기간 사용에 의해 열화가 많이 진전되었고, 특히 B상이 수트리 길이 및 화학구조결함 농도 면에서 가장 열화된 케이블인 것으로 판단되며, C상, A상의 순으로 열화정도가 다소 감소함을 확인하였다. 상기 결과는 진단시험 및 파괴 강도시험 결과와 일치하며, 따라서 열화시정수법을 이용한 진단장치가 열화상태가 심각한 케이블의 선별에 효과적인 진단법임을 확인하였다.

변압기용 고효율 차음판의 진동 및 소음 비교 (Comparison of vibration and noise of higher utility factor Insulation Panel for Transformer)

  • 정재환;이정환;정한얼;임동수;김진;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.112-116
    • /
    • 2007
  • Highly damped insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in inner city is appeared a lost of problem by increasing to conserve living environment. Therefor in this paper, the vibration and noise characteristic effect of cork-type and sponge-type that is attached between insulation panel and enforce beam in transformer is analized using real size transformer experimentally.

  • PDF

전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰 (Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation)

  • 이한주;정의환;조성훈;윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

고압전동기 고정자권선의 건조상태에 따른 절연특성 변화사례 고찰 (Example study of the insulation characteristic change according to the dryness condition in high voltage motor stator winding)

  • 공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2056-2057
    • /
    • 2008
  • This paper is purpose to understand the insulation properties of the high voltage motor stator winding according to the different dryness conditions. we carried out the three times insulation diagnosis test for the same motor stator winding. the first test object is the contaminated winding, second is the washed-out, and natural dried during the 24 hours, and the last is the heating dried in 110$^{\circ}C$ during the 48 hours. the insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, we analyzed and made a comparison of the three cases test result.

  • PDF