• 제목/요약/키워드: insulation characteristic

검색결과 283건 처리시간 0.032초

$SF_{6}$-$N_2$ 혼합기체의 절연특성에 관한 연구 (A study of the Insulation Characteristic in $SF_{6}$-$N_2$ Mixture Gases)

  • 하성철;송병두
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.613-616
    • /
    • 2001
  • This $SF_{6}$ gas is widely used in industrial of insulation field. In this paper, $N_2$ is mixed to improve pure $SF_{6}$ gas characteristics. Electron transport coefficients in $SF_{6}$-$N_2$ mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results of this method, which are like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient, and critical E/N, can be important data to present characteristic of gas for insulation. Specially critical E/N is a data to evaluate insulation strength of a gas and is presented in this paper for various mixture ratios of $SF_{6}$-$N_2$ mixture gases.

  • PDF

부스닥트용 에폭시 분체도료의 열 및 수중열화에 대한 전기적 특성 (Electrical Properties about Thermal and Water Degradation of Epoxy Powder for Bus Duct)

  • 김현희;김상현
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.17-22
    • /
    • 2009
  • 에폭시 분체도료는 부스닥트, 및 전기기기에 절연재료로 광범위하게 사용되어 진다. 특히 Coating 절연 방식의 경우 전류에 의한 줄 열로 인해 전기화재 및 폭발의 점화 원인이 된다. 본 연구는 에폭시분체도료의 열화특성에 대해 절연파괴, 아크방전, 수명특성(V-t)을 중심으로 비교검토하고 이에 대한 기초데이터 확보 및 전기화재 원인인 절연특성에 대해 연구 하였다. 온도변화에 따른 절연특성은 시편 KS가 유리전이온도(Tg) 이전까지 $8{\sim}10%$ 정도의 감소로 안정적이었다. V-t 및 아크방전특성의 경우, 열화시편에서도 안정적 특성을 유지하였다. 열화에 의한 전기적특성의 경우 시편KS가 우수한 성능을 가지고 있다.

SF6 가스 절연변압기의 절연특성과 부분방전 (Insulation Characteristics and Partial Discharge for the SF6 Gas Insulated Transformer)

  • 선종호;김우성;김광화;오원근;하영식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.740-747
    • /
    • 2000
  • This paper describes insulation characteristics and partial discharge for the SF6 gas insulated transformer. The characteristic of gas insulated transformer and the degradation sequence of solid insulation under SF6 gas atmosphere were explained. The model electrode system of the types that the aramid papers were inserted between two sphere electrodes was prepared. The partial discharge tests were carried out to that system and the insulation characteristics were considered.

  • PDF

폐발포폴리스티렌을 활용한 경량단열모르타르의 열전도율 및 역학적 특성 (Mechanical and Conductivity Characteristic of Lightweight Insulation Mortar Using Wasted Foam Polystyrene)

  • 강혜주;황병일;진은미;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.250-251
    • /
    • 2017
  • In study, the lightweight insulation mortar is produced with more than 50,000tons of waste each year, but it is difficult to treat with the degradable composite material and the recycling ratio is still 50%. the lightweight insulation mortar is manufactured by using the ratio of expanded polystyrene and pulverized expanded polystyrene.

  • PDF

절연진단법을 이용한 고전압전동기 고정자권선의 절연특성분석 (Analysis of Insulation Characteristics for High-voltage Motor Stator Winding using Insulation Diagnostic Test)

  • 오봉근;강현구;김현일;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.404-405
    • /
    • 2009
  • Insulation diagnostic tests for high voltage motor stator winding were conducted to analyze the insulation characteristics. Test motors were manufactured same factory and year(1996). Insulation characteristics of moisture winding are different from those of deteriorative winding. Insulation resistance and disscipation factor test results are sensitive to moisture winding. AC current, disscipation factor tip-up and PD test results are sensitive to deteriorative winding. Also, Capacitance value for stator winding insulation material has characteristic of increasing in moisture winding.

  • PDF

Dry Air Gas를 적용한 초고압 Switchgear 절연특성연구 (A Study on Dielectric Strength and Insulation Property of High Voltage Switchgear Applied Dry Air Gas)

  • 정동훈;정영환;서경보;김태한;김정배;이학성
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1731-1737
    • /
    • 2008
  • This paper present the fundamental insulation characteristics of Dry Air gas and insulation coating in high voltage power apparatus. It is known that the dielectric strength. of Dry Air is approximately one-third that of SF6 gas. we attempt that the insulation coating and dry air gas have replaced the SF6 gas as insulation of the switchgear. We proposed the dry air insulated switchgear(DAIS) for High Voltage apparatus. To acquire technology of insulation characteristic improvement made standards for complex insulation structure and conducted simulations and experiments

고온초전도 케이블의 절연설계를 위한 적층효과 (Multi-layered Effect for the Insulation Design of a HTS Cable)

  • 곽동순;천현권;김해종;조전욱;정순용;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

회전자 고정자권선의 절연보수후 절연특성변화 연구 (Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement)

  • 오봉근;최교남;최형철;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

고압회전기 절연진단 및 수명평가 기술현황 (A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine)

  • 최영찬;왕종배;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF

배관 보온필름의 화재특성에 관한 연구 (A Study on the fire characteristic of pipe insulation film materials)

  • 이영삼;이장원;이동호
    • 대한안전경영과학회지
    • /
    • 제14권2호
    • /
    • pp.65-70
    • /
    • 2012
  • This study was performed to test the combustive properties of the pipe insulation materials which are mainly used in the industries and buildings. Fire characteristic test of pipe insulation film according to the KS F ISO 5660-1 was performed. The experimental materials commonly used in the pipe insulation were used four kinds of films. Two kinds of 4 types of products that have the flame retardant performance and the other two types of them have no flame retardant performance. They were selected for fire characteristic test. The result of finding 25kW/$m^2$ radiation from the ignition was that flame retardant products were 140sec and the other one were 69sec in average of heat release rate(HRR). The result of flame retardant products in the 50kW/$m^2$ was 34sec and the other one were 15sec in average of HRR. However, the HRR of flame retardant products was much higher than the other one. Flame propagation test was conducted according to the KOFEIS 1001. The result of flame retardant products was that flame retardant products had a hold without fire spread after firing them. But the other one were completely fired after firing them. Therefore, I want to recommend that flame retardant products need to be used by the regulation to prevent or decrease a fire spread.