• Title/Summary/Keyword: instrument system

Search Result 1,599, Processing Time 0.03 seconds

Introduction of Total Management System for Oceanographic Instruments Using RFID(Radio Frequency IDentification) (전자태그를 이용한 해양 연구 기기 및 장비 통합 관리시스템)

  • Lee, Jung-Han;Hwang, Keun-Choon;Kim, Eun-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.192-204
    • /
    • 2011
  • With the international increasing of the important of oceanic researches related to climate changes, resources conservation and development and the advanced application of oceanic researches, advanced countries in ocean have developed the systematic management systems for oceanographic instruments. Despite the increasing realization of need for the establishment of management system, no systematic management system has been built in KOREA. There is an ungently need to construct the efficient and professional maintenance and management system of oceanographic instruments that are extremely expensive for meeting the increasing demands of oceanographic observation and investigation. In this paper, the present possession of oceanographic instruments in KOREA and the need for the establishment of management systems for oceanographic instruments are discussed. In addition, we introduce the total management system for oceanographic instruments using a RFID(Radio Frequency IDentification) at KORDI and discuss the necessity of the introduction and establishment for producing high quality data in oceanic researches.

A Comparison of the Effectiveness of Stainless-Steel Hand Instrument and Rotary NiTi Retreatment Instrument to Remove Gutta-Percha in Curved Root Canals (만곡된 근관에서 Gutta-Percha 제거 시 스테인리스스틸 수기구와 회전식 NiTi 재치료용 기구의 효과 비교)

  • Nam, Dong-Goo;Kim, Min-Jeong;Cho, Hye-Jin;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.99-107
    • /
    • 2011
  • The main objective of nonsurgical retreatment is to disinfect the root canal space for periradicular healing. Thus, efficient removal of the filling material from the root canal system is essential to ensure a favorable outcome. Traditionally, the removal of root canal filling material was performed by stainless steel hand instrument and this procedure is time and effort-consuming. Recently, rotary NiTi retreatment instruments are developed to effective removal of root canal filling material. The aim of this study was to evaluate the effectiveness of stainless-steel hand instrument and rotary NiTi retreatment instrument when removing gutta-percha in curved root canals. For the remaining materials, there were no significant differences between groups. But the rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

A Study on the Menu Type of Instrument Cluster IVIS

  • Kim, Hye Sun;Jung, Kwang Tae;Lee, Dhong Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.189-198
    • /
    • 2013
  • Objective: This research was carried out to study the menu type design of instrument cluster IVIS(In Vehicle Information System) for efficient navigation under deconcentrated situations. Background: A driver controls the IVIS menu using the rest of cognitive resources while driving a car. Although a driver controls the IVIS using extra cognition resources, his or her distraction can still cause some safety problems while driving. Menu type design of instrument cluster is absolutely important for safe and efficient navigation. Method: Four menu types including paging, flow, icon, and list type were identified through reviewing the existing IVIS of vehicle and the menu structure of cellular phone. Four menu types were evaluated through experiment. The experiment consisted of primary and secondary task, which the primary task was to simulate a driving and the secondary task was to control an IVIS menu prototype. Task performances, menu type preferences, and eye-movement patterns were measured in this experiment. Results: The result shows that icon type was the best design in aspect of task performance and preference. A clue for next menu item provided a positive effect for efficient menu navigation. It was identified that most of subjects gazed the middle-top area of IVIS screen from eye-movement pattern. Conclusion: A basic design of Instrument Cluster IVIS was proposed considering the result of this study in the final. Application: The results of this study can be effectively used in the design of Instrument Cluster IVIS.

Development of needle guidance system and its evaluation for ultrasound-guided follicular aspiration (초음파유도 난포채란기의 개발과 이의 검증)

  • Choi, Min-cheol;Lee, Hyo-jong;Cho, Seong-keun;Kang, Tae-yung;Won, Hyun-hui
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.6
    • /
    • pp.1210-1217
    • /
    • 1999
  • This study was carried out to develop a newly designed ovum pick-up(OPU) instrument for ultrasound-guided transvaginal follicular aspiration in cows. This new instrument consists of out- & inner-layer stainless pipes and a grip with a trigger(hand) switch. Some gauge types of disposable needles and tubes can be attached to this inner pipe. With this instrument, while grasping an ovary with one hand, the other hand can handle in apiration and vacuum on/off with the least assitant's help. With this instrument the mean recovery rate of bovine follicular oocytes was 45.2%. In recovered oocytes, usable oocytes(Grade I & II) were 30.4% and this rate meant 1.4 oocytes per ovary. For 30 days after initial aspiration with this instrument, some adverse effects such as adhesion, hemorrhage, hematoma and other mass formation in/with ovaries were also examined by rectal examination, ultrasonographic and endoscopic images. Adhesion was found in one ovary 1 week after aspiration, and hemorrhagic lesion was found 1-2 days and petechia were found 3-5 days after aspiration and there was no remarkable adverse effects. It was found that this instrument could be applicable and safe for ovum pick-up in cows.

  • PDF

Power System Design for Next Generation LEO Satellite Application (차세대 저궤도 소형위성 적용을 위한 전력시스템 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jan, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.283-287
    • /
    • 2005
  • In this paper, one general approach is proposed for the design of power system that can be applicable for next generation LEO satellite application. The power system consists of solar panels, battery, and power control and distribution unit(PCDU). The PCDU contains solar array modules, battery interface modules, low-voltage power distribution modules, high-voltage distribution modules, heater power distribution modules, on-board computer interface modules, and internal DC/DC converter modules. The PCDU plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. We review the functional schemes of the main constitutes of the PCDU such as the battery interface module, the auxiliary supply module, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, spacecraft unit power distribution modules, and instrument power distribution module.

  • PDF

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF

The Development of the Automatic Operation System for the Laboratories Equipment based on MATLAB GUI (MATLAB GUI 기반의 실험·실습실 자동화 운용 시스템 개발)

  • Wee, Sang-Bong;Park, Ji-Hong
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.2
    • /
    • pp.158-161
    • /
    • 2012
  • Wee developed the automatic operation system for the laboratories equipment based on MATLAB GUI. By using Instrument Control Tool Box and standard protcol, PC and equipments are well connected each other. Wee developed the software to control the display of input and output between PC and equipments by using MATLAB GUI, This system will be effectively used in laboratories and experimental facilities and more in on-line education system for experiments.

  • PDF

Study of Stray-light Analysis and Suppression Methods for the Spectroscopic System of a Solar-radiation Observer Instrument

  • Zheng, Ru;Liu, Bo;Wang, Lingyun;Gao, Yue;Li, Guangxi;Li, Changyu
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.220-228
    • /
    • 2021
  • To improve the measurement accuracy of a solar-radiation observer instrument, aiming at the problem of multiorder-stray-light interference caused by the diffraction of the flat-field concave grating in the spectroscopic system, straylight suppression methods for different forms of optical traps are studied. According to the grating surface-scattering distribution-function model, the bidirectional scattering distribution function (BSDF) of a dust-polluted surface and the flat-field concave grating's transition area of the spectroscopic system is calculated, and a Lyot stop with blade baffle is designed to suppress this kind of stray light. For diffraction multiorder stray light, based on the theory of light-energy transmission, a design for precise positioning of the trench optical trap is proposed. The superiority of the method is verified through simulation and actual measurement. The simulation results show that in a spectroscopic system approximately 160 mm × 140 mm × 80 mm in size, the energy of the stray light is reduced by one order of magnitude by means of the trench optical trap and Lyot stop, and the number of beams is reduced from 5664 to 1040. The actual measurements show that the stray-light-suppression efficiency is about 69.4%, which is effective reduction of the amount of stray light.