• Title/Summary/Keyword: instantaneous energy

Search Result 281, Processing Time 0.03 seconds

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Estimation on the Power Spectral Densities of Daily Instantaneous Maximum Fluctuation Wind Velocity (변동풍속의 파워 스펙트럴 밀도에 관한 평가)

  • Oh, Jong Seop
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2017
  • Wind turbulence data is required for engineering calculations of gust speeds, mean and fluctuating loading. Spectral densities are required as input data for methods used in assessing dynamic response. This study is concerned with the estimation of daily instantaneous maximum wind velocity in the meteorological major cities (selected each 6 points) during the yearly 1987-2016.12.1. The purpose of this paper is to present the power spectral densities of the daily instantaneous maximum wind velocity. In the processes of analysis, used observations data obtained at Korea Meteorological Adminstration(KMA), it is assumed as a random processes. From the analysis results, in the paper estimated power spectral densities function(Blunt model) shows a very closed with von Karman and Solari's spectrum models.

A Study on the Development of Hydrogen Fueled Engine : Heat Loss of Direct Injection Hydrogen Fueled Engine (수소기관 개발을 위한 기초연구(직접분사식 수소기관의 열손실))

  • Nam, Seong Woo;Lee, Jong Tai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.5 no.2
    • /
    • pp.111-119
    • /
    • 1994
  • Analysis of heat loss is needed to achieve the high performance and high efficiency in hydrogen engine. So, cooling losses at each part of the direct injection hydrogen fueled engine were measured to evaluate the behavior and distribution of heat loss. Unsteady instantaneous temperature and heat flux at cylinder head were measured by use of instantaneous temperature prove. And these results were compared with those of gasoline engine.

  • PDF

Instantaneous Voltage Sag Corrector Using Series Compensator in Transfer Power Line Generator (송전선 직렬보상을 이용한 순시전압강하 보상기)

  • Lee, Sang-Hoon;Min, Wan-Ki;Jeon, Byeong-Seok;Lee, Dae-Jong;Hong, Hyun-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.21-25
    • /
    • 2006
  • This paper describes the novel control techniques design of VSC(Voltage Sag Corrector) for the purpose of power line quality enhancement. A fast detecting technique of voltage sag is implemented through the detection of instantaneous value on synchronous rotating do-reference frame. The first order digital filter is added in the detection algorithm to protect the insensitive characteristics against the noise. The relationship between the total detection time and cut-off frequency of the filter is described. The size of the capacitor bank used as the energy storage element is designed from the point of view of input/output energy with circuit analysis. Finally, the validity of the proposed scheme is proven through the simulated results.

PTV velocity field measurements of flow around a triangular prism located behind a porous fence (다공성 방풍벽 뒤에 놓인 삼각 프리즘 주위 유동의 PTV 속도장 측정)

  • Kim, Hyeong-Beom;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.5
    • /
    • pp.708-715
    • /
    • 1998
  • The shelter effect of a porous wind fence on a triangular prism was experimentally investigated in a circulating water channel. A porous fence of porosity .epsilon.=38.5% was installed in front of the prism model. The fence and prism model were embedded in a turbulent boundary layer. The instantaneous velocity fields around the fence and prism model were measured by using the instantaneous velocity fields around the fence and prism model were measured by using the 2-frame PTV(Particle Tracking Velocimetry) system. By installing the fence in front of the prism, the recirculation flow region decreases compared with that of no fence case. The porous fence also decreases the mean velocity, turbulent intensity and turbulent kinetic energy around the prism. Especially, at the top of the prism, the turbulent kinetic energy is about half of that without the fence.

A Study on the Flash Point and Spontaneous Ignition Determination of Diethylene Glycol

  • Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • This study investigates the main factors of fire prevention, such as spontaneous ignition and flash point, while using Diehylene Glycol (DEG) as the antifreeze for automobile and industrial machines. Our results show the flash point of $142^{\circ}C$ and the minimum ignition temperature of $388^{\circ}C$ in the range of $130{\mu}{\ell}{\sim}150{\mu}{\ell}$. By increasing temperature to ignite in 1 second, an instantaneous ignition temperature of the sample is $569^{\circ}C$ in the sample amount of $140{\mu}{\ell}$.

On-Line Type Dynamic Voltage Restorer System by Improvement of EDLC's energy utilization ratio (EDLC의 Energy이용 향상에 의한 On-Line type Dynamic Voltage Restorer System)

  • Shon, Jin-Geun;Park, Jong-Chan;Seo, Il-Dong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1099-1101
    • /
    • 2007
  • In this paper, a study has been performed for development of dynamic voltage restorer(DVR) system using EDLC (Electric Double Layer Capacitor) to solve voltage sags which are considered the dominant disturbances affecting power quality. With the prolific use of semiconductor devices in electrical equipment, modern-day loads are becoming increasingly sensitive to the sags and the disturbances prove to be costly to industries. As a technology-driven custom power installation, the Dynamic Voltage Restorer (DVR) is recognized to be most effective equipment that can be used to counter the voltage sag problem. Hence, this paper proposes the high-performance optimal design of On-Line type DVR system which can efficiently compensate the instantaneous voltage sag and instantaneous interruption of the utility voltage source.

  • PDF

Control and Implementation of Dual-Stator-Winding Induction Generator for Variable Frequency AC-Generating System

  • Bu, Feifei;Hu, Yuwen;Huang, Wenxin;Shi, Kai
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.798-805
    • /
    • 2013
  • This paper presents the control and implementation of the dual-stator-winding induction generator for variable frequency AC (VFAC) generating system. This generator has two sets of stator windings embedded into the stator slots. The power winding produces the VFAC power to feed the loads, and the control winding is connected to the static excitation controller to control the generator for output voltage regulation with speed and load variations. On the basis of the idea of power balance, an instantaneous slip frequency control (ISFC) strategy using the information of both the output voltage and the output power is used in this system. A series of experiments is carried out on a 15 kW prototype for verification. Results show that the system has good static and dynamic performance in a wide speed range, which demonstrates that the ISFC strategy is suitable for this system.

Damage detection using both energy and displacement damage index on the ASCE benchmark problem

  • Khosraviani, Mohammad Javad;Bahar, Omid;Ghasemi, Seyed Hooman
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.151-165
    • /
    • 2021
  • This paper aims to present a novelty damage detection method to identify damage locations by the simultaneous use of both the energy and displacement damage indices. Using this novelty method, the damaged location and even the damaged floor are accurately detected. As a first method, a combination of the instantaneous frequency energy index (EDI) and the structural acceleration responses are used. To evaluate the first method and also present a rapid assessment method, the Displacement Damage Index (DDI), which consists of the error reliability (β) and Normal Probability Density Function (NPDF) indices, are introduced. The innovation of this method is the simultaneous use of displacement-acceleration responses during one process, which is more effective in the rapid evaluation of damage patterns with velocity vectors. In order to evaluate the effectiveness of the proposed method, various damage scenarios of the ASCE benchmark problem, and the effects of measurement noise were studied numerically. Extensive analyses show that the rapid proposed method is capable of accurately detecting the location of sparse damages through the building. Finally, the proposed method was validated by experimental studies of a six-story steel building structure with single and multiple damage cases.

Blasting wave pattern recognition based on Hilbert-Huang transform

  • Li, Xuelong;Wang, Enyuan;Li, Zhonghui;Bie, Xiaofei;Chen, Liang;Feng, Junjun;Li, Nan
    • Geomechanics and Engineering
    • /
    • v.11 no.5
    • /
    • pp.607-624
    • /
    • 2016
  • Rockburst is becoming more serious in Chinese coal mine. One of the effective methods to control rockburst is blasting. In the paper, we monitored and analyzed the blasting waves at different blast center distances by the Hilbert-Huang transform (HHT) in a coal mine. Results show that with the increase of blast center distance, the main frequency and amplitude of blasting waves show the decreasing trend. The attenuation of blasting waves is slower in the near blast field (10-75 m), compared with the far blast field (75-230 m). Besides, the frequency superposition phenomenon aggravates in the far field. A majority of the blasting waves energy at different blast center distances is concentrated around the IMF components 1-3. The instantaneous energy peak shows attenuation trend with the blast center distance increase, there are two obvious energy peaks in the near blast field (10-75 m), the energy spectrum appears "fat", and the total energy is greater. By contrast, there is only an energy peak in the far blast field, the energy spectrum is "thin", and the total energy is lesser. The HHT three dimensional spectrum shows that the wave energy accumulates in the time and frequency with the increasing of blast center distance.