• Title/Summary/Keyword: instantaneous energy

Search Result 282, Processing Time 0.032 seconds

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

Digital Demodulator Design and Characteristics Using Algebraic Separation and Energy Operator from Undersampled Two-Component AM-FM Signals (저표본화된 주성분의 AM-FM 신호들로부터 대수적 분리와 에너지 연산자를 사용한 복조기 설계 및 특성)

  • Sohn, Tae-Ho;Lee, Min-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.643-649
    • /
    • 1999
  • In this paper, we proposed that i) noise-tolerant four kinds of AM(Amplitude Modulation)-FM(Frequency Modulation) demodulators are designed, ⅱ) we derived undersampling frequency through the product via energy operator of the monocomponent AM-FM signals separated form two-component AM-FM signals, and ⅲ) these four kinds of AM-FM demodulators detect respectively information signals of the IA(Instantaneous Amplitude) and IF(Instantaneous Frequency) by undersampling frequency to be different each other from the undersampled monocomponet AM-FM signals. Particularly, the proposed algorithm can control undersampling frequency by an integer factor. And these efficient AM-FM demodulators are well worked with the undersampled AM-FM signals.

  • PDF

The Mapping Theory between Current/Voltage and Instantaneous Powers in Three-phase Systems (3상 계통에서 전류/전압과 순시전력간의 맵핑이론)

  • 김효성;최재호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.228-232
    • /
    • 1997
  • The relation between instantaneous active/reactive powers and currents is defined by voltage mapping matrix in three-phase four-wire systems. Control strategies for an active filter without energy storage components are proposed on the basis of mapping matrices. It can compensate for the zero-sequence current, irrespectively of whether or not a zero-sequence voltage exists in a three-phase four-wire system.

  • PDF

Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side (공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템)

  • Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

Online structural identification by Teager Energy Operator and blind source separation

  • Ghasemi, Vida;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.135-146
    • /
    • 2020
  • This paper deals with an application of adaptive blind source separation (BSS) method, equivariant adaptive separation via independence (EASI), and Teager Energy Operator (TEO) for online identification of structural modal parameters. The aim of adaptive BSS methods is recovering a set of independent sources from their unknown linear mixtures in each step when a new sample is received. In the proposed approach, firstly, the EASI method is used to decompose structural responses into independent sources at each instance. Secondly, the TEO based demodulation method with discrete energy separation algorithm (DESA-1) is applied to each independent source, and the instantaneous frequencies and damping ratios are extracted. The DESA-1 method can provide the fast time response and has high resolution so it is suitable for online problems. This paper also compares the performance of DESA-1 algorithm with Hilbert transform (HT) method. Compared to HT method, the DESA-1 method requires smaller amounts of samples to estimate and has a smaller computational complexity and faster adaption due to instantaneous characteristic. Furthermore, due to high resolution of the DESA-1 algorithm, it is very sensitive to noise and outliers. The effectiveness of the proposed approach has been validated using synthetic examples and a benchmark structure.

A study of a combined release model using perturbation solutions (섭동해를 이용한 혼합 누출에 관한 연구)

  • Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.41-48
    • /
    • 2014
  • Leak of liquid has been categorized conventionally into instantaneous release and continuous release. In this study, the spread of cryogenic liquid due to limited period of release is investigated for the first time to establish a new classification method with recognizing the irrationality of the conventional one. Such physical phenomena are governed by simultaneous equations concerning volume, radius and height of pool of the cryogenic liquid, and major parameters are evaporation rate per unit area, time of release, and spill quantity. The simultaneous governing equations is decoupled to get efficiently perturbation solutions. As the results, for the same spill quantity, in view of release model, combined release model that consists of continuous and consecutive instantaneous model is necessary with small time of release, while continuous model is solely required with large time of release. Also, the combined model is necessary for small spill quantity with the same time of release. These two regimes of release are clearly distinguished using the perturbation solution to provide a clear basis for the new classification of release models.

Dynamic Instability and Instantaneous Frequency of a Shallow Arch With Asymmetric Initial Conditions (비대칭 초기 조건을 갖는 얕은 아치의 동적 불안정과 순시 주파수 변화)

  • Shon, Sudeok;Ha, Junhong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.2
    • /
    • pp.77-85
    • /
    • 2020
  • This paper examined the dynamic instability of a shallow arch according to the response characteristics when nearing critical loads. The frequency changing feathers of the time-domain increasing the loads are analyzed using Fast Fourier Transformation (FFT), while the response signal around the critical loads are analyzed using Hilbert-Huang Transformation (HHT). This study reveals that the models with an arch shape of h = 3 or higher exhibit buckling, which is very sensitive to the asymmetric initial conditions. Also, the critical buckling load increases as the shape increases, with its feather varying depending on the asymmetric initial conditions. Decomposition results show the decrease in predominant frequency before the threshold as the load increases, and the predominant period doubles at the critical level. In the vicinity of the critical level, sections rapidly manifest the displacement increase, with the changes in Instantaneous Frequency (IF) and Instant Energy (IE) becoming apparent.

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

Optimal Output-Feedback Control for Discrete-Time Linear System with Time-Delayed Output (출력 시간지연을 이용한 이산시간 선형시스템의 최적 출력제어)

  • Jung, Chul-Hwan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 1989
  • This paper proposed the new control law which is defined by instantaneous output and time delayed output. To analyze the system with time delayed output, the way which transforms output time delayed systEms into instantaneous output systems is presented. The output responses were more improved by the new control law thEn that of the instantaneous output control law. The algorithem for simulation and a numerical exemple are presented.

  • PDF

Fundamental Frequency Estimation based on Time-Frequency Analysis (시주파수 분석법을 이용한 음성의 기본주파수 검출)

  • Iem Byeong-Gwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.31-34
    • /
    • 2006
  • A simple robust fundamental frequency estimator on the time-frequency domain is proposed. Combined with the appropriately designed low-pass filter, the instantaneous frequency estimator based on the Teager-Kaiser energy function can detect the fundamental frequency of speech signal. The Teager-Kaiser function can be obtained through real computation and show the change of frequency as time goes. And when a speech block with N samples is processed with a lowpass fille. with length of L, it requires $O(N{\cdot}(L+5))operations,$ compared to $O(N{\cdot}2log_2N+L))operations$ in the recently introduced wavelet and conventional instantaneous frequency method. The computer simulation confirms the usefulness of the proposed fundamental frequency estimation method.