• 제목/요약/키워드: instantaneous RMS

검색결과 23건 처리시간 0.025초

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

순시치 자기포화 곡선에 의한 변압기 인덕턴스 산정 (Determination of Transformer Inductances using Instantaneous Magnetic Saturation Curve)

  • 현용탁;좌종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.74-77
    • /
    • 2001
  • The saturated winding inductances of a transformer are determined using the instantaneous magnetic saturation curve. The instantaneous curve is obtained from no load saturation curve in rms form by a direct piecewise linearized approach, then it is represented by a four-term ploynominal approximation. The saturated differential, effective and apparent winding inductances are computed from this curve, and these inductances are compared with the measured magnetizing inductance. The results show that the relation of $L_d<L_e<L_a$ exists and the computed apparent inductance is more close to the measured inductance.

  • PDF

가변부하 적용을 위한 고정밀 교류전원 제어시스템 (A High-precision AC Power Control System for Variable Loads Application)

  • 한운동;손진근
    • 한국ITS학회 논문지
    • /
    • 제7권3호
    • /
    • pp.74-81
    • /
    • 2008
  • 고정밀 교류전원 제어시스템은 교통관제등과 같은 가변 부하를 운영하는데 중요하다. 이러한 시스템은 가변부하에 대응하기 위하여 제어의 정밀성이 요구되며, 이를 위하여 AC/DC/AC 변환이 가능한 인버터를 주로 사용하게 된다. 따라서 본 논문에서는 고정밀 전류제어를 수행하기 위하여 개선된 전류계측 기법을 이용한 제어시스템을 제안하였다. 제안된 계측기법은 전류의 궤환된 계측을 순시적 실효치의 이동평균법을 사용하여 응답 및 정밀성을 개선한 방식이다. 컴퓨터 시뮬레이션 및 실험의 결과는 제안된 시스템의 타당성을 입증할 수 있었으며, 이는 항공관제 유도시스템의 조명제어 장치에도 폭넓게 적용되리라 사료된다.

  • PDF

순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법 (3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept)

  • 박성미;양지훈;박성준
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

다중 성분의 저표본화된 AM, FM 및 AM-FM 신호들의 복조와 성능 (Demodulation and Performance of Multicomponent Undersampled AM, FM and AM-FM Signals)

  • 손태호;황의천
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권7호
    • /
    • pp.399-406
    • /
    • 2000
  • We propose an nonlinear demodulation algorithm for undersampled multicomponent AM(Amplitude Modulation), FM(Frequency Modulation) and AM-FM signals. First, we derive respectively undersampling frequency of the AM, FM and AM-FM using undersampling scheme, and separate respectively monocomponent signals from multicomponent signals using periodic algebraic separation algorithm. In this case augmented separation matrix is very regular and sparse, it has a special structure. The proposed demodulation algorithm detects respectively message signals of the IA(Instantaneous Amplitude) and IF(Instantaneous Frequency) from descrete monocomponent AM, FM and AM-FM signals with an undersampling frequency to be controllable. Verifying the RMS(Root Mean Squares) errors of the detected signals, we show that the performance is excellent.

  • PDF

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

EMTDC를 활용한 자가용 수용가 차단기 투입전류 확률해석 (Statistical analysis of CB making current in large seals industrial load using EMTDC)

  • 윤재영;최흥관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.67-69
    • /
    • 2002
  • This paper presents the statistical analysis of the circuit breaker's making current in large sacle industrical loads using EMTDC. Typically, the making current includes DC components as the phase angel of making instances varies and represents as a instantaneous valus not rms. Consequently, in this paper, the statistical analysis results of making current and steady state fault current for typical industrial loads presents.

  • PDF

동해 울릉분지 북서지역 가스하이드레이트 부존 지시자의 탄성파 속성 분석 (Seismic Attribute Analysis of the Indicators for the Occurrence of Gas Hydrate in the Northwestern Area of the Ulleung Basin, East Sea)

  • 김경진;이보연;강년건;유동근;신국선;조영호
    • 지구물리와물리탐사
    • /
    • 제17권4호
    • /
    • pp.216-230
    • /
    • 2014
  • 동해 울릉분지 북서 해역에서 취득한 3차원 탄성파 탐사자료의 해석에 의하면 연구해역 내 천부퇴적층은 광역반 사면에 의해 분리되는 5개의 탄성파 단위로 구분되며, 다수의 단층을 수반하는 배사구조가 발달한다. 가스하이드레이트 안정영역 내에는 높은 RMS 진폭을 보이는 해저모방반사면과 낮은 RMS 진폭을 보이는 음향공백대가 특징적으로 분포한다. 탄성파 속성 분석에 의하면 가스하이드레이트와 자유가스가 동시에 부존한 경우 그 경계를 따라 순간진폭이 높게 나타나며 하부에서 순간주파수가 급격히 감소한다. 반면 가스하이드레이트만 존재하는 경우에는 하부에서 순간진폭이 낮고 순간주파수가 감소하지 않는다. 해저모방반사면의 주파수 성분 분해 결과 특정 고주파수 영역에서 나타나는 강한 진폭은 하부 자유가스에 의한 튜닝효과를 지시한다. 가스하이드레이트, 자유가스 및 퇴적층의 경사를 고려한 네 가지 가스하이드레이트 부존모델을 제시하고 그 특징을 기술하였다.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

음향 가진 하에서 비예혼합 화염거동에 관한 가시화 연구 (A visual investigation of non-premixed flame behavior under acoustic excitation)

  • 이기만;오세기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.871-877
    • /
    • 2001
  • Experimental study was conducted to investigate the effects of axial forcing on the flame structures near the nozzle exit of non-premixed flame. The most notable observation is that the direction of vortical motions is changed at some ranges, according to the increase of excitation amplitude. Especially, the elongation flame and the phenomenon of In-burning are always occurred when the vortical motion turnabout. In an analysis of the flame/flow visualization by means of direct photography and RMS technique, a plausible explanation can be made that above phenomena are related only to the amplitude of phase average velocity between the instantaneous velocity elements of excited flow.

  • PDF