• 제목/요약/키워드: installation devices

검색결과 527건 처리시간 0.022초

전동차용 종합제어장치 소프트웨어 개발 (A Development on the software of Train Control and Monitoring System(TCMS) for Subway Train)

  • 최병욱;박종헌
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.94-100
    • /
    • 2011
  • TCMS is the most important controller in the subway train for reliable train control and service oriented flexibility. TCMS software charges communications and control of train and maintains control devices so we use QNX for real-time control. This paper introduces overall software development of TCMS using various diagrams. Software implementation details in TC and CC are explained using deployment diagram through train configuration. Driving control process among many processes is focused to present implement details which controls train by driver or automatic train operation and handles commands to control deriving devices in cars. Reliable operation of train and easy maintenance process is achieved through the same hardware in train control computer and car control computer.

새로운 고조파 저감형 고역율 단상정류 회로 (A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit)

  • 김칠용;문상필;조만철;서기영;권순걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.

저압 피뢰기 적용시 뇌서지 억제 효과 검토 (Discussion On The Protective Effect of Lightning Surge based on The Surge Protective Devices for Low Voltage)

  • 이석우;황규현;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.40-42
    • /
    • 2004
  • Electronic equipments made from electrical circuits with small-sized semiconductor are very weak against lightning surge. So, electronic equipments is protected by SPD(surge protective devices) such as Zno varistor. The SPD protect electronic circuit in electronic equipments and AC power lines from the lightning surge. Therefore to achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect and installation method of surge protective device. Therefore this paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

기기 수명을 고려한 배전계통 커패시터의 설치 계획 (Optimal Capacitor Placement in a Distribution System Considering Lifetimes of Devices)

  • 박종영;박종근
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.164-171
    • /
    • 2008
  • This paper proposes the planning method for placement of capacitors in a distribution system. The main objectives in the planning for capacitor allocation are the reduction of installation costs and electric power loss. In the proposed method, the life time of each device is considered in calculating installation costs, and the optimal operation status of devices is found by genetic algorithm. Then, the optimal numbers and locations are determined based on the optimal operation status. Simulation results in the 69-bus distribution system show that the proposed method performs better than conventional methods.

Fitness Sharing Particle Swarm Optimization Approach to FACTS Installation for Transmission System Loadability Enhancement

  • Chang, Ya-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 2013
  • Proper installation of Flexible AC Transmission Systems (FACTS) devices in existing transmission networks can enable power systems to accommodate more power transfer with less network expansion cost. The problem to maximize transmission system loadability by determining optimal locations and settings for installations of two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). For solving the MDCP, in the paper, the proposed method with fitness sharing technique involved in the updating process of the particle swarm optimization (PSO) algorithm, can diversify the particles over the search regions as much as possible, making it possible to achieve the optimal solution with a big probability. The modified IEEE-14 bus network and a practical power system are used to validate the proposed method.

매입형 영구자석 동기전동기 구동용 인버터 스위칭 소자의 개방 고장 진단 (A Diagnosis Scheme of Switching Devices under Open Fault in Inverter-Fed Interior Permanent Magnet Synchronous Motor Drive)

  • 최동욱;김경화
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.61-68
    • /
    • 2012
  • This paper deals with a fault diagnosis algorithm for open faults in the switching devices of PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. The proposed diagnostic algorithm is realized in the controller using the informations of three-phase currents or reference line-to-line voltages, without requiring additional equipments for fault detection. Under switch open fault conditions, the conventional dq model used to control an AC motor cannot directly be applied for the analysis of drive system, since three-phase balanced condition does not hold. To overcome this limitation, a fault model based on the line-to-line voltages is employed for the simulation studies. For comparative performance evaluation through the experiments, the entire control system is implemented using digital signal processor (DSP) TMS320F28335. Simulations and experimental results are presented to verify the validity of the proposed diagnosis algorithm.

서지보호기의 일시과전압특성에 대한 실험적 연구 (Experimental Study on Temporary Overvoltage Characteristic of Surge Protective Devices)

  • 심해섭;전태현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.344-347
    • /
    • 2009
  • Surge protective devices (SPD) have a special position because of the expectation that they perform an effective protective function against various kinds of surges. However, there exists a misconception that the SPD satisfying lower measured limiting voltage (MLV) should also protect equipment against temporary overvoltages (TOVs) as well. This paper inspects various types of MOV based SPDs and carry out experiments on the side effects of the low MLV characteristics. The experiment results show that a low MLV could cause a higher TOV-induced SPD failure rate in the field.

  • PDF

LED터널등 모듈의 폐열활용을 위한 열전소자의 발전 성능 분석 (Analysis of the Thermoelectric Devices' Power Generation Performance for Utilizing the Waste Heat of LED Tunnel Lighting Module)

  • 정지영;허인성;이세일;김명호;유영문
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.1-6
    • /
    • 2015
  • In this paper, we propose the LED(Light-Emitting-Diode) emergency lighting in a tunnel by using the thermoelectric devices. To achieve high generated power, thermoelectric device should be have high Seebeck coefficient and small contact area. Also, we reveal that a moderate heatsink required for high generated power. From the waste heat of LED tunnel lighting module (25W), the generated power was 0.062W by thermoelectric device, and it could illuminate for 1hour after charge the battery of emergency lighting during about 101hours.

자동심장충격기 설치현황 및 관리실태와 사용능력조사 - 충청남도 내 500세대 이상 아파트를 중심으로 (A survey on installation, management, and usability of automated external defibrillators - Focused on apartments with over 500 households in Chungnam)

  • 정준호
    • 한국응급구조학회지
    • /
    • 제21권3호
    • /
    • pp.73-84
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the installation, management, and usability of automated external defibrillators (AED) installed in the apartments with over 500 households in Chungnam. Methods: The survey included 52 apartments with over 500 households having AED in Chungnam from July 1 to August 20, 2017. The information of AED was taken from the Chungnam Provincial Office. Results: The access and use of AED was closely affected by AED installation location, locking devices, lack of publicity, and AED use education for the residents. Conclusion: Efficient education on the use and management of AED for residents of the apartments is necessary.