• Title/Summary/Keyword: installation/management

Search Result 1,158, Processing Time 0.039 seconds

Real-time Water Supply Facilities Monitoring System based on the USN (USN 기반의 실시간 수도설비 모니터링 시스템)

  • Kim, Yong-Tae;Yoo, Neung-Hwan;Park, Gil-Cheol;Kim, Seok-Soo;Kim, Tai-Hoon;Lee, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1207-1213
    • /
    • 2007
  • This paper has researched water supply facilities management using real-time water utility monitoring system based on USN(Ubiquitous Sensor Network) which is consisted of wireless sensors transferring waterworks facilities md treatment information about a valve-room and flowmeter-room of water supply installation. In the manholes, it was installed with flowmeter, pressure sensors, vibration sensors, Co-sensors, and hydro-thermograph sensors. These measurement values which are received by PDA are used for facilities operation on the spot safely and conveniently. It has also provided safe installation management via CDMA(Code Division Multiple Access) network which transfers data to remote servers to monitoring at a distance place. With safety management system of water supply facilities on USN technology convenience and safety is increased in real situation, and it is expected that we can supply clean water to people as much safer and more effective water supply installation management.

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

Analysis and Development for Installation Safety Standard on Gas Boiler Exhaust System (가스보일러 배기시스템 설치 기준 분석 및 개발 (가스보일러 배기시스템 관련 설치 안전기준 개발II))

  • Lee, Soo-jeong;Choi, Kyoung suhk;Chae, Chung-keun;Kim, Ha na;Yun, Jin sun
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.111-112
    • /
    • 2014
  • Exhaust gas boiler system with respect to national and international safety standards, comparative study best suited to the realities of local exhaust and exhaust system manufacturing, certification standards and gas boiler installation, management, and mip draft inspection standards will proceed through this study.

  • PDF

An Improved Spatial Electric Load Forecasting Algorithm (개선된 지역수요예측 알고리즘)

  • Nam, Bong-Woo;Song, Kyung-Bin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.397-399
    • /
    • 2007
  • This paper presents multiple regression analysis and data update to improve present spatial electric load forecasting algorithm of the DISPLAN. Spatial electric load forecasting considers a local economy, the number of local population and load characteristics. A Case study is performed for Jeon-Ju and analyzes a trend of the spatial load for the future 20 years. The forecasted information can contribute to an asset management of distribution systems.

  • PDF

Management after installation of artificial reefs;Present Condition and Development Scheme (인공어초 사후관리 현황과 발전방향)

  • Lee, Sung-Il;Ahn, Seung-Hwan;Kim, Dong-Sun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.160-161
    • /
    • 2005
  • It is important to manage artificial fish reefs with installation for restoration. The instruments of survey for artificial reefs condition(location, amount etc.) is Side Scan Sonar and Multi-beam sonar. The efficient and economic survey of the artificial reefs facility is the complete survey of the SSS(Side Scan Sonar) in all area first and then the survey of the artificial reefs by MBES(Multi Beam Echo Sounder) in the finding area.

  • PDF

Lead-acid battery management system in UPS (UPS의 납축전지 관리 시스템)

  • 임영철;변성천;김의선;장영학
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.177-180
    • /
    • 1998
  • To manage lead-acid battery efficiently and to use it longer in UPS, the state of charge(SOC) indicator of the battery is needed. So a new approach to developing battery SOC indicator for UPS is discussed in this paper. This method to determining SOC by combining the available data of discharge characteristics of a battery with neural networks(NN) is presented. The 3-layered NN with back propagation algorithm has been used. Exprement results show that the proposed method is appropriate as SOC indicator of the battery.

  • PDF

The Management of the Exhibits for the Lighting Standard of Museum (박물관의 전시조명기준에 따른 유물 관리 방안)

  • Han, Jong-Sung;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.217-221
    • /
    • 2005
  • 박물관에 전시된 유물의 관람을 위해서는 조명이 요구되며, 조명에서 제공되는 가시광선, 자외선 및 자외선에 의해 손상을 입을 수 있다. 조명에 의한 손상을 방지하기 위해서 손상의 원인을 완벽히 제거한다는 것은 기술적, 실용적으로 쉽지가 않다. 따라서 손상의 원인을 완벽히 제거하기보다는 적절한 조명기준 등을 정하여 손상의 최소화를 위한 노력이 실질적인 수단이라 생각된다. 본 연구에서는 우리나라 중앙박물관의 박물관의 전시조명기준에 의거한 유물의 등급별 적산조도 등의 설정 기준에 따른 적용방법과 유지관리 방안 등을 제안하였다.

  • PDF

다구찌 방법을 이용한 알루미늄 배선 덕트의 스위칭 노이즈(Noise) 특성에 관한 연구

  • 홍석묵;박명규
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.05a
    • /
    • pp.205-209
    • /
    • 2001
  • A study to analyze and solve problems of multi wire installation duct experiment has presented in this paper We have taken Taguchi's parameter design approach, specifically orthogonal array, and determined the optimal levels of the selected variables through analysis of the experimental results using S/N ratio.

  • PDF

A Study on Temporary Installation Art in Public Place (공공공간에서의 일시적 설치미술에 대한 연구 및 제언)

  • Zheng, zheng;Chen, juan;Ro, Hae-sin;Kim, Won-seok
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.313-317
    • /
    • 2019
  • Installation art is another methodology of modern art appeared in 1970's. Installation art does not seek for a particular ideology or specific form to express, but rather it endeavors to produce a work produced by mutiful media convergence and integration. Therefore, this leads to inspire new cognition on ordinary places. Installaton art is strongly related with public art in terms of most works are to be exhibited. Thus from this point of view, installation art contains public art which aims to better communication among people, nature and artificial things. Eventually, temporary installation art contains communication and convergence of people and object in public places.

A Study on the Efficient Energy & Manpower Management in Post Office Building : Focused on Introduction of Total Resource Group Management System (우정건축물(郵政建築物)의 효율적(效率的)인 에너지 및 인력(人力) 관리(管理) 방안(方案) - 통합 자원 군(群) 관리시스템의 도입을 중심으로 -)

  • Gang, Oh-Sik;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.25-30
    • /
    • 2007
  • Most part of the energy consumption of MIC(Ministry of Information and Communication) is mainly due to operation/maintenance of the post office buildings. In this paper, the pattern of energy consumption & operating status in post office buildings in Korea is analyzed. The authors suggest integrated and grouped management of the dispersed post office buildings using internet, through which we can expect increased efficiency.

  • PDF