• Title/Summary/Keyword: insertion

Search Result 4,256, Processing Time 0.031 seconds

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

A Study of N-Insertion Preferences in Korean (선호도 조사를 통한 ㄴ첨가 현상의 실현 양상 연구)

  • Kook, Kyungnk-A;Kim, Ju-Won;Lee, Ho-Young
    • MALSORI
    • /
    • no.53
    • /
    • pp.37-60
    • /
    • 2005
  • A Study of N-Insertion Preferences in KoreanKyung-A Kook, Ju-Won Kim, Ho-Young LeeSince n-insertion is not an obligatory process in Korean, it is necessary to investigate what factors influence n-insertion preferences and whether n-insertion preferences have been changed over time. To find answers to these questions, an n-insertion preference test using a questionnaire was conducted. 183 words were selected for this test and 167 subjects participated in the test. The results of this test show that the n-insertion preferences were influenced by the speakers' age, the number and structure of the syllable, word class, phonetic environments, and familiarity. It is suggested that the results of this test should be incorporated into the Principles of Standard Pronunciation and in the Grand Dictionary of Standard Korean.

  • PDF

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

Linear Complexity of 1-Symbol Insertion Sequences from m-Sequences (최대주기 수열의 1-심볼 추가 선형복잡도)

  • Chung, Jin-Ho;Yang, Kyeong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.6-11
    • /
    • 2008
  • From a periodic sequence, we can obtain new sequences with a longer period by r-symbol insertion to each period. In this paper we review previous results on the linear complexity of periodic sequences obtained by r-symbol insertion. We derive the distribution of the linear complexity of 1-symbol insertion sequences obtained from m-sequences over GF(p), and prove some relationship between their linear complexity and the insertion position. Then, we analyze the k-error linear complexity of the 1-symbol insertion sequences from binary m-sequences.

Robotic Needle Insertion Using Corneal Applanation for Deep Anterior Lamellar Keratoplasty (각막 압평을 이용한 로봇 바늘 삽입법: 심부표층각막이식수술에의 적용)

  • Park, Ikjong;Shin, Hyung Gon;Kim, Keehoon;Kim, Hong Kyun;Kyun., Wan
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.64-71
    • /
    • 2021
  • This paper describes a robotic teleoperation system to perform an accurate needle insertion into a cornea for a separation between the stromal layer and Descemet's membrane during deep anterior lamellar Keratoplasty (DALK). The system can reduce the hand tremor of a surgeon by scaling the input motion, which is the control input of the slave robot. Moreover, we utilize corneal applanation to estimate the insertion depth. The proposed system was validated by performing the layer separation using 25 porcine eyes. The average depth of needle insertion was 742 ± 39.8 ㎛ while the target insertion depth was 750 ㎛. Tremor error was reduced from 402 ± 248 ㎛ in the master device to 28.5 ± 21.0 ㎛ in the slave robot. The rate of complete success, partial success, and failure were 60, 28, and 12%, respectively. The experimental results showed that the proposed system was able to reduce the hand tremor of surgeons and perform precise needle insertion during DALK.

Effects of EMLA Cream Application on Pain Perception and Pain Response of Children with Cancer During Implanted Venous Access Port Needle Insertion (EMLA크림 도포가 소아암환자의 피하매몰 중심정맥포트 바늘삽입 시 통증인지와 통증반응에 미치는 영향)

  • Seo, Hyun-Young;Kim, Young-Hae
    • Child Health Nursing Research
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of EMLA (Eutectic Mixture of Local Anesthetics) cream application on pain perception and pain response during insertion of implanted venous access port needle in children with cancer. Methods: From December 2010 to August 2011, at U university hospital, 20 patients scheduled for implanted venous access port needle insertion were recruited, and randomly assigned to receive either EMLA or a placebo cream 1 hour before the implanted venous access port needle insertion. While conducting needle insertion, changes in pulse and oxygen saturation on the pulse oxymeter monitor were measured and pain behavior reaction was also measured during needle insertion in the treatment room. After conducting needle insertion, self-reported pain reaction, and mothers' perception of the children's pain reaction were measured. Collected data were statistically processed using SPSS version 17.0 for Windows, and analyzed using descriptive statistics, t-test. Results: Children's self-reported degree of pain, degree of pain as perceived by mothers and pain behavior reaction decreased significantly in the EMLA application group compared with the placebo group. Conclusion: Findings indicate that application of EMLA cream is effective in relieving pain in these children during implanted venous access port needle insertion.

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

  • Katic, Visnja;Kamenar, Ervin;Blazevic, David;Spalj, Stjepan
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.177-183
    • /
    • 2014
  • Objective: To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy$^{(R)}$, Aarhus, and Dual Top$^{TM}$) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

Development and Effects of Fear-Reduction Program for Malignant Disease Children with Inserting Implanted Port (이식형 포트 삽입 학령전기 아동의 주사공포감소를 위한 프로그램 개발 및 효과)

  • Yang, Kyung-Ah;Chang, Sook;Kim, Il-Ok
    • Korean Parent-Child Health Journal
    • /
    • v.8 no.1
    • /
    • pp.37-48
    • /
    • 2005
  • Purpose: The purpose of this study was to develop a play education program to reduce children's fear of needle insertion to the implanted port, and to assess the effect of this program. Method: The play education program was composed of play education before needle insertion, encouragement during needle insertion, and a present to reward then after needle insertion. Measurement instruments were the Procedure Behavior Check List(PBCL) and Faces Rating Scale(FRS). Results: The first hypothesis, "the PBCL point of children with malignant disease would decrease after play education program", was rejected(before insertion : Z=-0.189, p= .850, during insertion : Z=-0.350. p= .727, after insertion : Z=-0.590, p= .555). The second hypothesis, "the FRS point of children with malignant disease would decrease after play education program education", was rejected(observer 1 : Z=-0.245, p= .806, observer 2 : Z=-0.912, p= .362, self-report : Z=-0.181, p= .856). The third hypothesis, "the Time of needle insertion would decrease after play education program", was rejected(Z=-0.464, p= .642). Conclusion: The effect on fear-reduction of play education program for children with malignant disease inserted implanted port was not significant but continuous education is needed for parents and children.

  • PDF

Comparison of success rates of orthodontic mini-screws by the insertion method

  • Kim, Jung Suk;Choi, Seong Hwan;Cha, Sang Kwon;Kim, Jang Han;Lee, Hwa Jin;Yeom, Sang Seon;Hwang, Chung Ju
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.242-248
    • /
    • 2012
  • Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mmlong mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.