• 제목/요약/키워드: inner diameter

검색결과 968건 처리시간 0.028초

재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구 (A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support)

  • 최명기;박종근
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

DICOM 영상을 이용한 외이도 음향해석 방법에 관한 연구 (A Study on the Acoustic Analysis Method of the External Ear Canal Using DICOM Images)

  • 김형균
    • 한국융합학회논문지
    • /
    • 제10권3호
    • /
    • pp.73-79
    • /
    • 2019
  • 머리 측두부 디지털 영상 및 통신 표준 영상을 이용한 외이도 길이, 상하 굴곡각도, 내 외경 비율에 따른 음향민감도를 외이도 모델링으로 시뮬레이션하고 측정하였다. 실험은 인간 가청주파수 기준으로 200Hz씩 증가하면서 1 파스칼의 압력으로 일정하게 전달된 주파수를 고막 음향크기로 나타내어 그 측정값들을 선형과 이차곡선 회귀분석으로 나타내었다. 그 결과 외이도 길이는 길수록, 외 내경 둘레의 비율은 높을수록 낮은 주파수에서 빠른 음향적 반응을 나타내었다. 회귀분석을 이용한 메타모델의 음향민감도 상관관계는 외이도 길이가 77%, 외 내경 비율 5%의 영향으로 나타났지만 상하 굴곡각도는 특별한 관계를 나타내지 못하였다. 이로써 인간의 청각음향 민감도는 외이도 길이가 길수록, 외 내경 둘레의 비율 차이가 높을수록 낮은 주파수에서 빠르게 반응하는 인자임을 알 수 있었다.

세관내 HCFC계 대체냉매의 압력강하에 관한 연구 (The Pressure Drop Characteristics in Small Diameter Tubes Using HCFC Alternative Refrigerants)

  • 손창효;이호림;정진호;최영석;오후규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.347-352
    • /
    • 2000
  • The pressure drop characteristics of R-22 and R-410A(a mixture of 50wt% R-32 and 50wt% R-125) flowing in a small diameter tube with 1.77[mm] inner diameter and 3.14[mm] outer diameter was investigated experimentally. the mass fluxes of refrigerants are ranged from 450 to $1050[kg/(m^2{\cdot}s)]$ and the qualites are varied from 0.05 to 0.95. The main experimental results were summarized as follows; The single-phase liquid friction factors for small diameter tubes are higher than those predicted by the Blasius equation. In case of two-phase flow, the pressure gradient of the small diameter tube increases with increasing mass velocity and vapor quality. The experimental data are not well correlated by predictions which were proposed for the large diameter tube.

  • PDF

세관내 R-22 대체냉매의 응축열전달에 관한 연구 (The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes)

  • 손창효;정진호;오종택;오후규
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

세관내 R-22 대체냉매의 응축압력강항에 관한 연구 (The Condensation Pressure Drop of Alternative Refrigerants for R-22 in Small Diameter Tubes)

  • 오후규;손창효;최영석;김기수
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1245-1252
    • /
    • 2001
  • The condensation pressure drop for pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 [mm] length with horizontal copper tube of 3.38 [mm] outer diameter and 1.77 [mm] inner diameter. The refrigerant mass fluxes ranged from 450 to 1050 [kg/(㎡$.$s)] and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of single-phase flow, the pressure drop of R-134a is much higher than that of R-22 and R-410A for the same Reynolds number. The friction factors for small diameter tubes are higher than those predicted by Blasius equation. In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-134a is much higher than that of R-22 and R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data. However, the correlation predicted by Honda et al showed relatively good agreement with experimental data for R-134.

ISO 규격에서 규정한 표준용기 기체도입 도관의 직경에 대한 고찰 (Consideration on the Thickness of the Gas Introducing Tube of the Test Dome Specified in the ISO Standard)

  • 인상렬
    • 한국진공학회지
    • /
    • 제19권3호
    • /
    • pp.161-168
    • /
    • 2010
  • 진공펌프의 배기성능 지표들을 정량적으로 측정하기 위해서 사용하는 표준용기에 관한 ISO 규격은 기체도입 도관의 굵기를 용기 내경의 10분의 1로 규정하고 있다. 표준용기 내경은 검사 대상 펌프의 흡기구 직경보다 작아서는 안 되므로 만일 대용량 펌프에 맞춘다면 때에 따라 도관의 굵기가 100 mm라는 수치도 나올 수 있다. 전체 시스템의 크기가 커지는 만큼 이런 굵기의 도관도 수용이 가능하기는 하지만 과연 이렇게 굵은 도관이 정밀한 측정을 위해 꼭 필요한지 또는 오히려 방해가 되는 것은 아닌지 검토해 볼 필요성이 있다. 본 논문에서는 도관 굵기에 따라, 도관출구를 빠져나오는 입자들과 오리피스 및 펌프 흡기구에 입사하는 입자들의 등방성에 대해 살펴봄으로써 적절한 도관 굵기가 존재하는지에 대해 논의한다.

세관내 R-134a의 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1307-1312
    • /
    • 2007
  • 본 논문은 세관내 R-134a의 유동특성을 실험적으로 조사한 것이다. 이에 대한 실험장치는 마그네틱 기어 펌프, 증발기, 수액기, 사이트 글라스, 응축기 계측기로 구성된다. 유동양식을 관찰하기 위한 사이트 글라스는 증발기 입출구에 설치하였다. 실험은 세관내 R-22와 R-134a의 유동특성을 살펴보기 위해서 수행되었다. 이에 대한 실험변수인 냉매질량 유속은 100에서 1000 $kg/m^2s$이고, 포화온도는 $30^{\circ}C$이다. 증발과정 중의 유동양식에서 2 mm의 세관내 환상유동은 8 mm관의 대구경관에 비해 저건도와 저질량유속에서 발생하였다. 본 실헐 결과와 종래의 유동양식 선도와 비교한 결과, 2 mm의 세관내 증발 유동양식은 Baker, Mandhane, Taitel-Dukler의 유동양식 선도와는 큰 차이를 보였지만, Dobson의 유동양식 선도와는 좋은 일치를 보였다.

  • PDF

진도개에서 임신일령에 따른 임신구조물의 초음파상 II. 태아 및 태아외구조물의 측정에 의한 임신일령의 추정 (Ultrasonographic appearance of the gestational structures throughout accurately timed pregnancy in Korea Jin-do dogs II. Estimation of gestational age by measurement of the fetal and extra-fetal structures)

  • 손창호;신창록;강병규;최한선
    • 대한수의학회지
    • /
    • 제36권1호
    • /
    • pp.247-254
    • /
    • 1996
  • Serial ultrasonographic examinations were performed on 9 pregnant Korea Jin-do dog from days 15 to 60 to determine the size of gestational structures throughout pregnancy. Gestational age was timed from the day of ovulation (Day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0 ng/ml. Extra-fetal structures were measureable from days 17 to 49. Outer uterine diameter increased from $7.0{\pm}0.7$ ($mean{\pm}SD$)mm at day 17 to $54.0{\pm}2.2mm$ at day 49 and inner chorionic cavity diameter increased from $3.0{\pm}0.7mm$ at day 17 to $37.5{\pm}0.6mm$ at day 49. Uterine wall thickness increased from $2.8{\pm}0.4mm$ at day 17 to $8.3{\pm}0.5mm$ at day 49, placental thickness increased from $1.0{\pm}0.1mm$ at day 22 to $5.7{\pm}0.2mm$ at day 49 and length of chorionic cavity or zonary placenta increased from $5.5{\pm}1.3mm$ at day 20 to $52.3{\pm}2.2mm$ at day 49. Inner chorionic cavity diameter, outer uterine diameter and placental length each increased at a linear rate through day 37, after which time, each had a marked plateau in growth. Of the extra-fetal structures, inner chorionic cavity diameter was the most accurate for estimation of gestational age until day 37. Fetal structures were measureable from days l7 to 60. Crown-rump length, increased from $3.0{\pm}0.7mm$ at day 22 to $118.7{\pm}3.1mm$ at day 49, fetal body diameter increased from $4.0{\pm}0.7mm$ at day 25 to $55.8{\pm}1.7mm$ at day 60 and fetal head diameter increased from $4.3{\pm}0.6mm$ at day 26 to $29.8{\pm}0.8mm$ at day 60. Of the fetal structures, fetal head diameter was the most accurate for estimation of gestational age from day 37 until day 60.

  • PDF

Inner groove tube의 U형 Draw-Bending 가공기술에 관한 연구 (Manufacturing Technique on the U Type Draw-Bending of Inner Groove Tube)

  • 강흥식;김동성;허신;홍성인
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.148-151
    • /
    • 2003
  • The purpose of this study is to investigate the manufacturing technique on the U type Draw-Bending of inner groove tube. The U type tube requires the quality of product that satisfy sufficient conditions for a heat exchanger. The mandrel components act the important roles that prevent wrinkles and keep the shape of cross section of bended tube at bending process. We performed the FEM simulation using LS-DYNA software and the bending test of inner groove tube and then, compared bending simulation with bending test results about mandrel ball diameter, mandrel position and optimal clearance between mandrel and tube.

  • PDF