• Title/Summary/Keyword: inner channel

Search Result 240, Processing Time 0.026 seconds

CFD ANALYSIS OF FLOW CHANNEL BLOCKAGE IN DUAL-COOLED FUEL FOR PRESSURIZED WATER REACTOR (가압경수로 이중냉각핵연료의 내측수로 막힘에 대한 전산유체역학 해석)

  • In, W.K.;Shin, C.B.;Park, J.Y.;Oh, D.S.;Lee, C.Y.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.269-274
    • /
    • 2011
  • A CFD analysis was performed to examine the inner channel blockage of dual-cooled fuel which has being developed for the power uprate of a pressurized water reactor (PWR). The dual-cooled fuel consists of an annular fuel pellet($UO_2$) and dual claddings as well as internal and external cooling channels. The dual-cooled annular fuel is different from a conventional solid 려el by employing an internal cooling channel for each fuel pellet as well as an external cooling channel. One of the key issues is the hypothetical event of inner channel blockage because the inner channel is an isolated flow channel without the coolant mixing between the neighboring flow channels. The inner channel blockage could cause the Departure from Nucleate Boiling (DNB) in the inner channel that eventually causes a fuel failure. This paper presents the CFD simulation of the flow through the side holes of the bottom end plug for the complete entrance blockage of the inner channel. Since the amount of coolant supply to the inner channel depends on largely the pressure loss at the side hole, the pressure loss coefficient of the side hole was estimated by the CFD analysis. The CFD prediction of the loss coefficient showed a reasonable agreement with an experimental data for the complete blockage of both the inner channel entrance and the outer channel. The CFD predictions also showed the decrease of the loss coefficient as the outer channel blockage increases.

  • PDF

Analysis of Performance Characteristics by Inner Flow Path of Side Channel Type Ring Blower (사이드 채널형 링블로워의 임펠러 내부 유로에 따른 성능변화 분석)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeong, Kyung-Ho;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.67-71
    • /
    • 2012
  • This study analyzed performance changes by an inner flow path of impeller groove for side channel type ring blower using CFD. Two models have the same side channel and clearance while one has an inner flow path and the other doesn't. To analyze the performance change of a ring blower, overall performance and local flow field were analyzed. For the overall performance, pressure increase and impeller torque were checked under the design flow condition. Under the design flow condition, pressure increase was greater for the model with the inner flow path. The model with the inner flow path showed improved efficiency because the area subject to torque decreased due to the creation of inner flow path. To analyze local flow field, a section was created from the representative location of each impeller groove toward the direction of radius. Inner channel pressure distribution depending on the rotation direction shows that the model with the inner flow path has pressure equilibrium of working fluid through the inner flow path. Velocity distribution of inside impeller groove shows that flow field was coupled and appeared to form an inner wall where the flow field was stabilized.

The Applicability Study of U-Channel Bridge (U-Channel Brdige의 적용성 연구)

  • Choi, Dong-Ho;Lee, Joo-Ho;Park, Myoung-Gyun;Kim, Sung-Jae;Kim, Yong-Sik;Kim, Sung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.495-498
    • /
    • 2008
  • In this paper applicable range of U-Channel Bridge (UCB) that has recently been introduced as a new bridge type was studied. For structural analysis models used with the frame and plate elements was proposed, and verification of the models were performed. Using these structural models structural analysis of models with span length of 20m-45m and inner width of 5m-13m were performed. As a result for U-shape sections were applicable in the range of 20m span and 35m span, slab was applicable in the range of 5m inner width and 12m inner width. To increase applicable range of UCB H-shape sections and slab with rib were proposed. As a result UCB were applicable in the range of 20m span and 45m span, in the range of 5m inner width and 13m inner width.

  • PDF

Dynamic Stability Analysis of Annular Cylindrical Fuel Rod in Axial Flow (축류에 놓인 환형 실린더 연료봉의 동적 안정성 기초해석)

  • Lee, Kang-Hee;Kim, Hyung-Kyu;Yoon, Kyung-Ho;Lee, Young-Ho;Kim, Jae-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.264-267
    • /
    • 2008
  • Dual-cooled fuel with inner and outer flow channel was proposed for high burup, next generation nuclear fuel design. The annular cylinder of dual cooled fuel has higher structural strength compared to the conventional one, but also have concerns about flow induced vibration due to an additional flow of inner channel and the difference of flow velocity in between inner and outer channel. In this study, the dynamic stability of flexible, annular cylinder was evaluated according to the flow variation and compared to the that of the conventional PWR fuel rod. Centrifugal and Coriolis force by the additional flow in the inner channel were added in the dynamic equation of flexible beam in uniform, external, and axial flow. Complex eigenfrequency was calculated by the finite element method. Stability margin of annular cylinder compared to the solid cylinder and change of the dynamic characteristic are presented and discussed as a analysis results.

  • PDF

Multi-Access Points Transmit Power Control Algorithm in Consideration of the Channel Estimation Error and the Multi Rate Service (채널추정 에러와 다중 전송률 서비스를 고려한 다수 개의 엑세스포인트 전송전력제어 알고리즘)

  • Oh, Changyoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • We propose a multi-access points transmit power control algorithm in consideration of the channel estimation error and the multi-rate service. In the real communication systems, the channel estimation at the receiver side is imperfect due to limited number of pilot symbol usage. Furthermore, the multi-rate service is supported. We theoretically prove the uniqueness and the convergence of the proposed algorithm in multi-rate service environment. The proposed algorithm composes of one inner loop part and one outer loop part. Simulation results show that 1) the inner loop algorithm guarantees convergence of the transmit power level and the multi-rate service, 2) the outer loop algorithm compensates for the channel estimation error.

Capacity-Equivocation Region of a Special Case of Wiretap Channel with Noiseless Feedback

  • Dai, Bin;Han Vinck, A.J.;Luo, Yuan;Ma, Zheng
    • Journal of Communications and Networks
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2015
  • The general wiretap channel with noiseless feedback is first investigated by Ahlswede and Cai, where lower and upper bounds on the secrecy capacity are provided in their work. The upper bound is met with equality only in some special cases. In this paper, we study a special case of the general wiretap channel with noiseless feedback (called non-degraded wiretap channel with noiseless feedback). Inner and outer bounds on the capacity-equivocation region of this special model are provided. The outer bound is achievable if the main channel is more capable than the wiretap channel. The inner bound is constructed especially for the case that the wiretap channel is more capable than the main channel. The results of this paper are further explained via binary and Gaussian examples. Compared with the capacity results for the non-degraded wiretap channel, we find that the security is enhanced by using the noiseless feedback.

Optimum Inner and Outer Code Rates for Concatenated Codes in Gaussian Binary Symmetric Channels (가우시안 이진 대칭 채널에서 쇄상부호의 최적 내.외 부호율에 관한 연구)

  • Lee, Ye Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we address a problem of finding the optimum inner and outer code rates for a concatenated code in Gaussian binary symmetric channels. Clearly, as the inner code rate decreases, the error detection capability of the inner code increases. However, decreasing the inner code rate implies a decrease in error-correction capability of the outer code when overall code rate is fixed. With this notion in mind, we examine the optimum distribution of redundancy on the outer and inner codes to achieve a maximum performance gain in the concatenated coding scheme. Our analysis shows that the maximum coding gain can be obtained when the inner code rate is maximized and the outer code rate is minimized under the constraint of total code rate is fixed.

Characteristics of Ice Jam and flow in channel Bends (만곡수로에서의 Ice Jam과 흐름특성)

  • 윤세의
    • Water for future
    • /
    • v.21 no.4
    • /
    • pp.399-406
    • /
    • 1988
  • Presented in this paper is a brief summary of the basic theory and observation from a laboratory investigation aimed at determining flow characteristics and ice jam topography in a sinuous channel, and in a single-bend channel. The sinuous channel comprised thirteen $90^{\circ}$ bends and was of comparatively small s\aspect ratio. The single-bend channel was a $180^{\circ}$ bend, which was an order of magnitude large in width as well as aspect ratios than the sinuous channel. The simulated ices were polyethylene and polypropylene beads and block. The streamwise velocities near the bottom were larger than that of surface in sinuous channel and forming ice jam in sinuous channel, this phenoumena were found strongly. Jams were generally thicker along the inner bank of bends. The path of maximum-streamwise velocity was displaced towards approachs side of the inner bank of bends. Radial variation of jam thickness was to be regular by increasing size of ice fragments. The rate of jam head progression around outer bank of the single bend was faster than that of inner bank and its velocity was roughly steady. With increasing Froude number, jm thickness became less uniformly distributed; being generally thicker along the inner bank and near the jam's toe. Two-layer model might be adaptable for the computing the streamwise velocity in shallow river bends. Two cells of secondary flow cound be expected in ice covered-river bends.

  • PDF

Characteristics of Leakage Flow on Regenerative Blower and Leakage-reducing Design for Performance Enhancement (재생형 블로워의 누설유동 특성과 누설유량 저감을 통한 성능 향상)

  • Choi, Min-Ho;Kim, Young-Hoon;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.57-63
    • /
    • 2011
  • Regenerative blower is suitable for hydrogen recirculation in fuel cell vehicle due to its capability of high pressure rise in single stage. Numerical models were applied to investigate inner gap leakage flow characteristics. A leakage flow in the inner gap is dominantly affected by pressure gradient. Therefore a blower with concentric channel type was suggested as one of modified models for reducing the inner gap pressure gradient. Also numerical results such as pressure rise, efficiency, leakage flow rate and torque were compared between modified and reference models. The performance of concentric channel type was improved as a result of reduced leakage flow.

Three-Channel Output Multiplexer Design Using Band-Pass Filter and Ultra-Wideband Antenna

  • Lee, Jung Nam;Park, Jong Kweon
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2016
  • We have designed a three-channel output multiplexer (OMUX) using a band-pass filter and an ultra-wideband (UWB) antenna. The proposed band-pass filter is composed of an inner rectangular loop, an outer open stub, and a defected ground structure. The outer open stub can be used to control the pass band, and the inner rectangular loop can improve the insertion loss characteristics of the band-pass filter. The proposed band-pass filter, UWB antenna, and OMUX are fabricated and measured. The designed OMUX can cover the band group 1 (3,168-4,752 MHz) of WiX system. The measured radiation patterns are close to those of a conventional dipole antenna and the measured antenna gain varies from 1.8 dBi to 3 dBi over the operating frequency range.