DOI QR코드

DOI QR Code

Characteristics of Leakage Flow on Regenerative Blower and Leakage-reducing Design for Performance Enhancement

재생형 블로워의 누설유동 특성과 누설유량 저감을 통한 성능 향상

  • 최민호 (서울대학교 대학원 기계항공공학부) ;
  • 김영훈 (서울대학교 대학원 기계항공공학부) ;
  • 강신형 (서울대학교 기계항공공학부)
  • Received : 2010.10.08
  • Accepted : 2011.02.21
  • Published : 2011.08.01

Abstract

Regenerative blower is suitable for hydrogen recirculation in fuel cell vehicle due to its capability of high pressure rise in single stage. Numerical models were applied to investigate inner gap leakage flow characteristics. A leakage flow in the inner gap is dominantly affected by pressure gradient. Therefore a blower with concentric channel type was suggested as one of modified models for reducing the inner gap pressure gradient. Also numerical results such as pressure rise, efficiency, leakage flow rate and torque were compared between modified and reference models. The performance of concentric channel type was improved as a result of reduced leakage flow.

Keywords

References

  1. Wilson W.A., Santalo M. A. and Oelrich J. A., 1955, "A theory of the fluid-dynamic mechanism of regenerative pumps," Transactions of the ASME, Vol. 77, pp. 1303-1316.
  2. Raheel M. M., 2003, "A theoretical, experimental and CFD analysis of regenerative flow compressors and pumps for microturbine and automotive fuel applications," Ph. D. Dissertation, Michigan State University.
  3. Engeda A. and Elkacimi Y., 2008, "A regenerative flow compressor as a secondary air pump for engine emission control," Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, Vol. 222, pp. 1707-1715. https://doi.org/10.1243/09544062JMES958
  4. Badami M., 1997, "Theoretical and experimental analysis of traditional and new periphery pumps," SAE International congress & Exposition.
  5. Song J. W., Engeda A. and Chung M. K., 2003, "A modified theory for the flow mechanism in a regenerative flow pump," Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, Vol. 217, No. 3, pp. 311-321. https://doi.org/10.1243/095765003322066538
  6. 최영석, 이경용, 강신형, 2003, "사이드채널형 연료펌프의 성능예측," 유체기계저널, 제6권, 제2호, pp 29-33. https://doi.org/10.5293/KFMA.2003.6.2.029
  7. 심창열, 강신형, 2003, "재생펌프의 유동해석 및 누설유동에 관한 연구," 대한기계학회논문집 B권, 제27권, 제8호, pp. 1015-1022. https://doi.org/10.3795/KSME-B.2003.27.8.1015
  8. 임형수, 강신형, 2005, "사이드채널형 재생펌프의 성능 특성에 관한 실험적 연구," 대한기계학회논문집 B권, 제29권, 제3호, pp. 306-313. https://doi.org/10.3795/KSME-B.2005.29.3.306
  9. Horiguchi H., Wakiya K., Tsujimoto Y., Sakagami M. and Tanaka S., 2008, "Study for the increase of micro regenerative pump head," Transactions of the JSME, Series B, Vol. 74, No. 746, pp. 2154-2162. https://doi.org/10.1299/kikaib.74.2154
  10. Hollenberg J. W., 1987, "Reynolds number effects on regenerative pump performance," Transactions of the ASME, Journal of Engineering for Industry, Vol. 109, pp. 392-395. https://doi.org/10.1115/1.3187144