• Title/Summary/Keyword: inlet concentration

Search Result 480, Processing Time 0.031 seconds

Biofilter를 이용한 diesel VOCs의 생물학적 제거

  • 이은영;최우진;최진규;김무훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.347-350
    • /
    • 2002
  • The petrochemical products can cause soil and groundwater contamination during their transportation and the use of the products, and while being contained in underground storage tanks(USTs) throughout the leakage. To treat the contaminated soil, the bioventing method is suitable for the remediation of semi-volatile compounds, such as diesel and kerosene. Biofiltration is one of possible method to treat the off-gas produced in the process of the bioventing. This study is related to the usage, effectiveness of treatment, and feasibility of two types of biofilter system made of ceramic-compost and polymer respectively to treat diesel VOCs at constant retention time of 20 sec. Compost biofilter showed the average removal efficiency of 73 % when the inlet concentration increased to 20 ppmv. Increased the inlet concentration decreased the microbial activities as well as the removal efficiency. On the contrary, the removal efficiency of the polyurethane biofilter was maintained at 88 % at the inlet concentration of 13 ppmv during ten days and was obtained to 80 % at the inlet concentration of 30 ppmv in spite of the drop of the efficiency in the sudden increase of the inlet concentration. At the beginning of the experiment it showed low removal efficiency at low inlet concentration due to the low microbial activity, however, as experiments proceed the removal efficiency could be obtained more than 80% at high inlet concentration.

  • PDF

Investigation of the concentration characteristic of RCS during the boration process using a coupled model

  • Xiangyu Chi;Shengjie Li;Mingzhou Gu;Yaru Li;Xixi Zhu;Naihua Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2757-2772
    • /
    • 2023
  • The fluid retention effect of the Volume Control Tank (VCT) leads to a long time delay in Reactor Coolant System (RCS) concentration during the boration process. A coupled model combining a lumped-parameter sub-model and a computational fluid dynamics sub-model is currently used to investigate the concentration dynamic characteristic of RCS during the boration process. This model is validated by comparison with experimental data, and the predicted results show excellent agreement with experimental data. We provide detailed fields in VCT and concentration variations of RCS to study the interaction between mixing in VCT and the transient responses of RCS. Moreover, the impacts of the inlet flow rate, inlet nozzle diameter, original concentration, and replenishing temperature of VCT on the RCS concentration characteristic are studied. The inlet flow rate and nozzle diameter of VCT remarkably affect the RCS concentration characteristic. Too-large or too-small inlet flow rates and nozzle diameters will lead to unacceptable long delays. In this work, the optimal inlet flow rate and nozzle diameter of VCT are 5 m3/h and 58.8 mm, respectively. Besides, the impacts of the original concentration and replenishing temperature of VCT are negligible under normal operating conditions.

A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method (반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구)

  • Song, Ho-Cheol;Lee, Yun-Gi;Park, Jin-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

Effects of Glucose and Ammonium Concentrations in Continuous Culture for Poly-$\beta$-hydroxybutyrate Production (Poly-$\beta$-hydroxybutyrate 생산을 위한 연속배양에서 포도당 및 암모늄 농도의 영향)

  • 이용우;유영제
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.5
    • /
    • pp.597-606
    • /
    • 1992
  • Effects of dilution rate, inlet glucose and ammonium chloride concentrations on ,he performance of continuous culture of Alcaligenes eutrQPhus for poly-p-hydroxybutyrate (PHB) production were investigated. When inlet substrate concentrations were maintained constant (inlet glucose concentration = 20 g/l, inlet ammonium chloride concentration = 2 g/l), growth rate of residual biomass and PHB production rate showed its maximum at $0.1h^{-1}$ and $0.06h^{-1}$, respectively, and washout at $0.13h^{-1}$. PHB content decreased from 50% to 25% by increasing dilution rate, while specific PHB production rate increased continuously. Cell mass and PHB concentration gave its maximum values at inlet ammonium chloride concentration of 2 g/l and thereafter decreased, which showed the existence of substrate inhibition by ammonium. When inlet glucose concentration was 30 g/l, cell mass reached its maximum value, while PHB concentration increased continuously. The parameters of kinetic model were evaluated by the graphical and parameter estimation methods. The computer simulation results for the effects of dilution rate, inlet glucose and ammonium chloride concentrations fitted the experimental data very well.

  • PDF

Simultaneous Removal of Hydrogen Sulfide and Ammonia Using Thiobacillus sp. IW in a Three-Phase Fluidized-Bed Bioreactor

  • Kum, Sung-Hoon;Oh, Kwang-Joong;Moon, Jong-Hae;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.419-422
    • /
    • 2000
  • A three-phase fluidized-bed bioreactor including Thiobacillus sp. IW was tested to remove H_2S and $NH_3$ simultaneously. The inlet $H_2S$ was oxidized to $SO_4^{2-}$ by Thiobacillus sp. IW, and the $NH_3$ reacted with the $SO_4^{2-}$ to form $(NH_4)_2SO_4$. The removal efficiency of $H_2S$ was 98.4-99.9% for an inlet concentration of 36-730 ppm and that of $NH_3$ was 60.2-99.2% for an inlet concentration of 45-412 ppm. The removal efficiency of $NH_3$ was reduced when the inlet loading rate of $NH_3$ was increased above 10 mg/l/h. When the bioreactor was operated for 25 days with a lower inlet concentration of $NH_3$ compared with the of $H_2S$, the bioreactor exhibited an excellent performance with a stable pH, dissolved oxygen content, and cell concentration.

  • PDF

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

A Numerical Simulation on Mixing Enhancement by Inlet Flow Pulsation in a Micro Conduit (마이크로 유로에서 맥동유동에 의한 혼합촉진에 관한 수치해석)

  • Kim, Seo-Young;Rhee, Gwang-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.231-237
    • /
    • 2003
  • A numerical study has been conducted to investigate the effect of an inlet flow pulsation on mixing of two solutions with different concentrations in a micro conduit. We treat an unsteady, incompressible and two-dimensional flow through a micro conduit by adopting the momentum equations with the electrostatic force due to streaming current and the concentration equation. The feasibility of the inlet flow pulsation to enhance the mixing process inside the micro conduit is carefully examined by varying the inlet pulsation frequency. When a low-frequency pulsation is induced at the inlet, the interface between two solutions with different concentrations becomes wavy, which results in mixing enhancement. As the pulsation frequency increases, the waviness of the interface becomes meager, and the concentration gradients at the interface approach the value for the non-pulsating steady flow.

  • PDF

Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer (호흡률 측정기를 이용한 파일럿 스케일 염색폐수처리 장치에서의 생물학적 활성 측정)

  • Jeon Hyun Hee;Choi Kwang Keun;Yoon In Jun;Lee Jin Won
    • KSBB Journal
    • /
    • v.19 no.5
    • /
    • pp.390-393
    • /
    • 2004
  • Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.

Removal Characteristics of Styrene Vapor in the Biofilter Packed with Loess/Polyurethane Composite Media (황토/폴리우레탄 복합담체를 충전한 Biofilter에서 기상 Styrene의 제거특성)

  • Kang Kyung-Ho;Kam Sang-Kyu;Lee Taek-Kwan;Lim Sang-Bin;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.1027-1033
    • /
    • 2005
  • The treatment of styrene vapor was carried out using the biofilter packed with loess/polyurethane composite during continuous operation of 74 days. The microorganisms were adapted within 2-3 days under the experimental conditions of inlet concentration and empty bed contact time (EBCT). At 200 sec of EBCT, the removal efficiency of styrene was 100\% with 200 ppmv of inlet concentration, while $92\%$ with 400 ppmv of inlet concentration. The biofilter showed the stable removal efficiencies of over $74\%$ under the EBCT range from 300 to 75 sec at the 150 ppmv of inlet styrene concentration. The maximum capacity of styrene removal for the biofilter packed with loess/polyurethane was $29g/m^3/hr$. During continuous operation of 74 days, pH of the drain water changed slightly and the pressure drop through the biofilter column was below $45\;mmH_2O/m$.

Catalytic Oxidation of VOCs using Photocatalysis (광촉매반응을 이용한 VOCs의 촉매산화)

  • 이승범;이재동
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.2
    • /
    • pp.52-59
    • /
    • 2003
  • This study was progressed in photocatalysis of VOCs using $UV/TiO_2$ which was a benign process environmentally. The experiments were peformed to know photodegradation characteristics as crystalline structure of $TiO_2$ which had anatase, rutile and P-25 (anatase : rutile = 70 : 30). The main purpose of this study was to identify photocatalytic characteristics as inlet concentration of reactants, $H_2O$, and residence time. The inlet concentration of VOCs was changed 50, 100 and 200 ppmv, and amount of $H_2O$ was changed 0, 500 and $1000{\;}mg/m^3$, respectively. The deep conversion was increased as the inlet concentration decreased, and the amount of $H_2O$ increased. The deep conversion of benzene had the highest value at $1000{\;}mg/m^3${\;}H_2O$ and 50 ppmv of inlet concentration. The reactivity of reactants was decreased in order benzene > toluene > m-xylene. Also, the photocatalytic deep conversion was increased as residence time increased, because the contact time between reactants and catalyst was increased. In this study, intermediates had not found by GC/MSD analysis. Therefore, the reactants were completely converted to $H_2O{\;}and{\;}CO_2$.