• Title/Summary/Keyword: injection wells

Search Result 83, Processing Time 0.026 seconds

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

Application of Well Allocation Factor for Injection Optimization of Waterflooding (수공법 주입량 최적설계를 위한 Well Allocation Factor 적용 연구)

  • Yoon, Su-Jin;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2015
  • For successful operation of waterflooding which is one of secondary recovery methods, suitable water injection allocation is important to increase oil recovery. Well allocation factor(WAF) which is one way to quantify the injector and producer connectivity, is utilized to allocate water injection of waterflooding. Static WAF cannot represent the field condition and can induce incorrect value. To compensate for limitation of static WAF, modified WAF which includes several parameters that affect patterns including well radius, distance between wells, and injection rates is proposed. In this study, static and modified WAFs were applied to injection optimization of waterflooding and results by each WAF were compared. In case of modified WAFs, produced water were less and produced oil were more than case of static WAF especially in big change of distance between producer and injector. Therefore, modified WAFs can allocate water injection more efficiently than static WAF.

Characterization of the Transport of Zero-Valent Iron Nanoparticles in an Aquifer for Application of Reactive Zone Technology (반응존 공법 적용을 위한 나노영가철의 대수층 내 이동 특성에 관한 연구)

  • Kim, Cheolyong;Ahn, Jun-Young;Ngoc, Tuan Huynh;Kim, Hong-Seok;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.109-118
    • /
    • 2013
  • Characteristics of the transport of zero-valent iron nanoparticles (nZVI) in an aquifer were investigated to evaluate an application of nZVI-based reactive zone technology. Main flow direction of groundwater was north. Preferential flow paths of the groundwater identified by natural gradient tracer test were shown northeast and northwest. The highest groundwater velocity was $4.86{\times}10^{-5}$ m/s toward northwest. When the breakthrough curves obtained from the gravity injection of nZVI were compared with the tracer curves, the transport of nZVI was retarded and retardation factors were 1.17 and 1.34 at monitoring wells located on the northeast and northwest, respectively. The ratios of the amount of nZVI delivered to the amount of tracer delivered at the two wells mentioned above were 24 and 28 times greater than that of the well on the main flow direction, respectively. Attachment efficiency based on a filtration theory was $4.08{\times}10^{-2}$ along the northwest direction that was the main migration route of nZVI. Our results, compared to attachment efficiencies obtained in other studies, demonstrate that the mobility of nZVI was higher than that of results reported in previous studies, regardless of large iron particle sizes of the current study. Based on distribution of nZVI estimated by the attachment efficiency, it was found that nZVI present within 1.05 m from injection well could remove 99% of TCE within 6 months.

An Analysis of Relationship between Cushion Gas and Gas Withdrawal in Depleted Gas Reservoir as a Gas Storage (고갈가스전의 가스저장전 전환 시 쿠션가스와 가스재생산율과의 관계 분석)

  • Han, Jeongmin;Kim, Joohyung;Sung, Wonmo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.9-20
    • /
    • 2013
  • Depleted gas reservoir has been already explored and its geologic data, along with its reservoir properties, are already known through seismic exploration and drilling. Therefore it would be less difficult to develope a gas storage from depleted gas reservoir. Cushion gas which remains in the reservoir to maintain pressure affects withdrawal rate of working gas in underground gas storage. In this study, we attempted to investigate the relationship between cushion gas and withdrawal rate using a commercial simulator. From the analyses of the results, it is found that the minimum limit for a cycle of 5-month injection and 5-month withdrawal is 10 wells with 50% cushion gas, and 12 wells with 60% cushion gas for a cycle of 7-month injection and 3-month withdrawal.

Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow (지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링)

  • Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront (친수지역 강변여과수 열원을 활용한 냉난방시스템 개발)

  • Cho, Yong;Kim, Dea Geun;Moon, Jong-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

Study on the aquifer utilization for a ground water heat pump system (지하수 히트펌프 시스템의 대수층 활용 사레 연구)

  • Shim, Byoung-Ohan;Lee, Chul-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Design of Optimal Wet-Season Injection Well for Augmenting Groundwater Resources in Coastal Areas (해안지역 지하수자원 확충을 위한 우기 인공주입정의 최적설계)

  • Park, Nam-Sik;Shi, Lei;Cui, Lei;Lee, Chan-Jong;Mun, Yu-Ri
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.5
    • /
    • pp.415-424
    • /
    • 2009
  • Artificial injection of surplus surface water during wet seasons and recovery is one of possible solutions for conjunctive uses of surface water and groundwater. The methodology is especially attractive for regions of monsoon type weather. In this work a simulation-optimization model is developed to identify an optimal injection system to sustain an over-exploiting freshwater pumping well. The injection well is to be operated during wet seasons only while the pumping well is to be operated throughout an entire year. The objective function is the minimization of injected volume of freshwater. Saltwater intrusion and dry wells are considered as constraints. An example application is made on a small hypothetical island with poor hydrogeologic conditions. The optimization model is successful in determining optimal injection locations and rates for various cases.

Case Study on Groß Schönebeck EGS Project Research in Germany (독일 그로스 쉐네벡 EGS 실증 프로젝트 연구사례)

  • Min, Ki-Bok;Park, Sehyeok;Zimmermann, Gunter
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.320-331
    • /
    • 2015
  • This paper presents a case study of an enhanced geothermal system(EGS) demonstration project conducted in $Gro{\ss}$ $Sch{\ddot{o}}nebeck$, Northerm Germany, focusing on hydraulic stimulation. The project was conducted with doublet system in sandstone and volcanic formations at 4 - 4.4 km depth. Under normal faulting to strike-slip faulting stress regime, hydraulic stimulations were conducted at injection and production wells by massive waterfrac and gel-proppant fracturing. Injectivity index increased from $0.97m^3/(hr^*MPa)$ to $7.5m^3/(hr^*MPa)$ and productivity index increased from $2.4m^3/(hr^*MPa)$ to $10.1m^3/(hr^*MPa)$ by a series of hydraulic stimulations at both wells. After circulation tests through injection and production wells, however, productivity index decreased from $8.9m^3/(hr^*MPa)$ to $0.6m^3/(hr^*MPa)$ in two years. Slip tendency analysis for the stimulation in volcanic layer estimated the required pressure for shear slip and its preferred orientations and it showed reasonable match with actual stimulation results. Through the microseismicity observation for the stimulation of volcanic formation, only 80 seismic events with its moment magnitudes in -1.8<$M_W$<-1.0 were observed, which are unexpectedly low for EGS hydraulic stimulation.

Preliminary Assessment of Groundwater Artificial Recharge Effect Using a Numerical Model at a Small Basin (수치모델을 이용한 소분지에서의 지하수 인공함양 효과 예비 평가)

  • Choi, Myoung-Rak;Cha, Jang-Hwan;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, the effects of groundwater artificial recharge through vertical wells in the upper small basin are preliminarily evaluated by using field injection test and a 3-D numerical model. The injection rate per well in a model is set to 20, 37.5, 60, and 75 ㎥/day based on the results of field injection test, groundwater levels, and hydraulic conductivities estimated from particle size analysis, and a numerical model using MODFLOW is conducted for 28 cases, which have diverse injection intervals, in order to estimated the changes of groundwater level and water balance after injection. Groundwater level after injection does not show a linear relationship with the injection rate per well, and the cumulative effect of artificial recharge decreases and the timing of maximum water level rise is shortened as the injection interval becomes longer. In four cases of continuous injection with total injection rate of 1,200 ㎥, it is revealed that the recharge effect is analyzed as 36.5~65.3% of the original injection rate. However, it will be more effective if the artificial recharge system combined with underground barrier is introduced for the longer pumping during a long and severe drought. Additionally, it will be possible to build a stable artificial recharge system by an establishment of efficient scenario from recharge to pumping as well as an optimization of recharge facilities.