• 제목/요약/키워드: injection seal

검색결과 35건 처리시간 0.026초

역방향스월자기주입 시일의 누설 성능에 관한 실험 연구 (Test Results of Leakage Performance for Anti-Swirl Self-Injection Seals)

  • 김창호;이용복
    • Tribology and Lubricants
    • /
    • 제7권2호
    • /
    • pp.41-45
    • /
    • 1991
  • An experimental investigation for leakage performance of five anti-swirl self-injection seals was carried out to select an optimum configuration for minimum leakage. Test results show that the self-injection mechanism with a plain seal generally degrades the leakage performance of noncontacting seals; however, through a series of the test program, an optimum anti-swirl self injection seal was selected to obtain a comparable leakage performance with a damper seal. A 12 holes anti-swirl and anti-leakage self-injected. configuration with a labyrinth surface gives minimum leakage among the tested anti-swirl self-injection seals.

고무 인젝션 방법을 이용한 플렉시블 씰 제작 (The Flexible Seal Fabrication utilizing a rubber Injection Method)

  • 김병훈;권태훈;조인현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.707-710
    • /
    • 2010
  • KSLV-I 킥모터 노즐 개발에 있어서 가장 중요한 개발품은 노즐 구동에 필요한 플렉시블 씰 개발이다. 특히 플렉시블 씰 제작 기술의 확보는 킥 모터 노즐 개발에 있어서 핵심 개발 사항 중에 하나였다. 킥모터 플렉시블 씰 제작에 사용된 방법은 금형에 순서대로 배열된 보강재 사이에 고무를 주입하는 인젝션 방식을 사용하였다. 플렉시블 씰 제작을 통해 금형 설계 기술, 고무 인젝션 방법, 성형 공정을 확립하였다. 제작된 플렉시블 씰은 X-Ray 검사를 통해 내부 접착 상태 및 보강재/고무 배열 상태를 확인하였다.

  • PDF

분사를 수반하는 평씨일 내의 유동해석 (Flow Analysis of the Plain Seal with Injection)

  • 이관수;김우승;김기연;김창호
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.795-802
    • /
    • 1992
  • 본 연구에서는 일정한 각도의 분사를 갖는 평씨일(plain seal)에 대하여 각 인자들이 누수성능에 미치는 영향을 수치적으로 조사하였다. 인자들로는 축방향 레 이놀즈수, 축회전속도, 분사의 유입속도, 간극비, 분사의 위치 및 유입각 등이 고려되 었다.

고분자 수지를 이용한 자동차 에어컨용 압축기의 씰에 관한 연구 (A Study on Compressor Seal for Automotive Air-conditioner using Polymer Resin)

  • 정태형;하영욱
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.22-27
    • /
    • 2002
  • The existing compressor steel seal used in automotive air-conditioner has the problem of oil leakage and the deterioration in shielding performance, due to the abrasion and the corrosion of the material. A new type of polymer resin seal is studied in the research. The polymer resin seal has the characteristics of high anti-abrasiveness and anti-corrosiveness, which can overcome the deflects of the steel seal. In addition, the seal needs lower manufacturing cost and is appropriate to mass production, because it is made by the injection molding method requiring no mechanical processing. The profile generation program for seal mold has been developed using the gradient method, and the molding characteristics of the seal have analyzed through the flow analysis and the warpage analysis. The program has been verified by comparing the analysis results with the measured data of the test product. The research might be said to provide the basic method to produce the polymer resin seals with various types and dimensions.

  • PDF

고분자 수지를 이용한 자동차 에어컨용 압축기의 씰에 관한 연구 (A Study on Compressor Seal for Automotive Air-conditioner using Polymer Resin)

  • 정태형;하영욱
    • 한국공작기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.81-87
    • /
    • 2002
  • The existing compressor steel seal used in automotive air-conditioner has the problem of oil leakage and deterioration in shielding performance, due to the abrasion and corrosion of the material. A new type of polymer resin seal studied in this research has the characteristics of high anti-abrasiveness and anti-corrosiveness, which can oversome the defects of the steel seal. In addition, the seal needs lower manufacturing cost and is appropriate to mass production, because it is made by the injection molding method requiring no mechanical processing. The profile generation program for seal mold has been developed using the gradient method, and the molding characteristics of the seal have analyzed through the flow analysis and the warpage analysis. The program has been verified by comparing the analysis results with the measured data of the test product. The research might be said to provide the basic method to produce the polymer resin seals with various types and dimensions.

산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지 (Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment)

  • 신정국;문승재;유호선
    • 플랜트 저널
    • /
    • 제7권1호
    • /
    • pp.56-63
    • /
    • 2011
  • The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.

  • PDF

고압펌프내 Anti-Swirl Injection형 씨일의 동특성 및 누설성능에 대한 연구 (A Study on the Dynamic Characteristics and Leakage Performance of Anti-Swirl Injection Type Seal in High Pressure Pumps)

  • 임순규;김광식;김창호;이용복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1990년도 추계학술대회논문집; 한양대학교, 서울; 24 Nov. 1990
    • /
    • pp.169-172
    • /
    • 1990
  • 본 논문에서는 모달해석을 통해 불안정성을 제거 할 수 있는 메카니즘 (mechanism)으로 만든 씨일(Anti-Swirl Injection type Seal: ASIS)의 등록 성 및 누수량, 압력 강하등을 평씨일, 댐퍼씨일 등과 비교, 해석하여 본질의 역할 및 안정성을 동시에 향상시킬수 있는 씨일을 연구해보고자한다.

  • PDF

점착유연형 고무 아스팔트계 누수보수용 주입형 실링재의 내화학 시험방법 개선 연구 (A Study on Chemical Resistance Test Method of the Adhesively Flexible Rubberized Injection Seal for Water Leakage Cracks in Concrete Structures)

  • 박완구;김동범;박진상;김선도;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.240-241
    • /
    • 2017
  • In this stduy, we will references to provide reasonable basis for the test environments applicable to the chemical resistance test covered by KS F 4935 『Injection-type Sealing Materials for Water Leakage Crack of Adhesive and Flexible Rubber Asphalt』, analyze the problems with the current test methods in consideration of the features of materials. As a result, we assured more objective data in improved chemical resistance test methods.

  • PDF

자동차 주유구 커버에 대한 사출성형과 2색 코팅 동시 구현에 관한 연구 (A study on simultaneous injection molding and two-color coating for car gas cap cover)

  • 배형섭;박동현;김부곤;서창호;허원근;이호상
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.32-40
    • /
    • 2021
  • Mold design for in-mold coating was carried out to achieve simultaneous injection molding and two-color coating for car gas cap cover. The developed mold includes one core and three cavities which are composed of a substrate cavity and two coating cavities. To provide a sealing edge for complete seal during the second coating, the first coated material was used at the boundary between the first coating and the second one, and injection molded substrate was used at the parting line. The materials used were PC/ABS for substrate and 2-component Polyurea for coating. Through experiments, it was found that the suggested sealing edges were effective for complete seal during the second coating. In cavity pressure traces, there were three peaks caused by mold closing, coating-material injection and cleaning-piston advancement inside the mixing head. The cavity pressure increased with decreasing coating thickness.

ANALYSIS OF THE ISP-50 DIRECT VESSEL INJECTION SBLOCA IN THE ATLAS FACILITY WITH THE RELAP5/MOD3.3 CODE

  • Sharabi, Medhat;Freixa, Jordi
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.709-718
    • /
    • 2012
  • The pressurized water reactor APR1400 adopts DVI (Direct Vessel Injection) for the emergency cooling water in the upper downcomer annulus. The International Standard Problem number 50 (ISP-50) was launched with the aim to investigate thermal hydraulic phenomena during a 50% DVI line break scenario with best estimate codes making use of the experimental data available from the ATLAS facility located at KAERI. The present work describes the calculation results obtained for the ISP-50 using the RELAP5/MOD3.3 system code. The work aims at validation and assessment of the code to reproduce the observed phenomena and investigate about its limitations to predict complicated mixing phenomena between the subcooled emergency cooling water and the two-phase flow in the downcomer. The obtained results show that the overall trends of the main test variables are well reproduced by the calculations. In particular, the pressure in the primary system show excellent agreement with the experiment. The loop seal clearance phenomenon was observed in the calculation and it was found to have an important influence on the transient progression. Moreover, the collapsed water levels in the core are accurately reproduced in the simulations. However, the drop in the downcomer level before the activation of the DVI from safety injection tanks was underestimated due to multi-dimensional phenomena in the downcomer that are not properly captured by one-dimensional simulations.