• 제목/요약/키워드: injection probe

검색결과 97건 처리시간 0.026초

가스터빈 입구에서의 유동 및 스칼라 분포 특성 (Measurement of Flow and Scalar Distribution at Gas Turbine Inlet Section)

  • 홍성국
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.45-50
    • /
    • 2010
  • The goal of paper is to investigate the flow and scalar distribution through the HP Nozzle Guide Vane (NGV) passage. Flow and scalar distribution measurement are conducted by using 5-hole pressure probe and $CO_2$ tracing technique, respectively. Three different experimental cases are considered depending on cooling flow condition. The result shows that the vortical secondary flow patterns are observed clearly and these flow characteristics maintain through the NGV passage regardless of cooling flow injection. Compared to center region, the high axial velocity flow is observed near wall region due to cooling flow injection. Without cooling flow, the $CO_2$ (scalar) distribution becomes to be uniform quickly due to the strong flow mixing phenomenon. However, in cases of cooling flow, scalar distribution is significantly non-uniform.

해저터널에서 주입에 의한 차수효과 연구 (A Study on the Impermeable Effect by Grouting in the Subsea Tunnel)

  • 김승환;임희대;윤성민
    • 한국지반환경공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.5-19
    • /
    • 2017
  • 본 연구에서는 편마암지역의 NATM 해저터널 막장 9개소에서 실시한 차수 주입홀 315공에 대한 주입재 주입량에 대하여 RMR 분류요소들과 주입재 주입량, 루전값과 RQD, 루전값과 시멘트 주입량의 상관관계를 분석하여 암반 차수 주입 효과를 연구하였다. 연구대상 해저터널에서 막장별 주입재 총주입량은 일부 막장에서 다소 변화폭은 있으나, 불연속면의 간격(R3, Js)과 지하수상태(R5)에서 분류요소의 평점이 높을수록 감소하는 것으로 나타났으며, 막장별 총주입량은 RMR 분류요소들보다는 탄성파탐사(3D, TSP)의 지질이상대 및 감지공의 유입량과 상관관계가 큰 것으로 나타났다. 단위주입량은 불연속면의 상태(Jc, R4)의 풍화도를 제외한 RMR 분류요소들에서 평점이 높을수록 감소하는 것으로 나타났다. RQD와 루전값은 상관관계가 크지 않으나, RQD 값이 클수록 루전값이 감소하는 경향을 확인할 수 있었다.

Buffered articaine infiltration for primary maxillary molar extractions: a randomized controlled study

  • Dhake, Parag;Nagpal, Devendra;Chaudhari, Purva;Lamba, Gagandeep;Hotwani, Kavita;Singh, Prabhat
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권5호
    • /
    • pp.387-394
    • /
    • 2022
  • Background: Dental pain management is an important aspect of patient management in pediatric dentistry. Articaine is considered the most successful anesthetic agent for infiltration anesthesia. Buffered articaine has been observed to have faster onset and longer duration of action with less pain on injection. The aim of this study was to evaluate and compare pain on injection, onset of action, and pain during extraction using buffered (using Sodium bicarbonate (NaHCO3)) and non-buffered 4% articaine (with 1:100000 adrenaline) infiltrations for primary maxillary molar extractions in 4-10-year-old children. Methods: Seventy children who required extraction of maxillary primary molars were enrolled in this triple-blind randomized study. Children undergoing extraction were randomly divided into two groups, with 35 in each group. The study group was the buffered articaine group; the control group was the non-buffered articaine group. Buccal and palatal infiltrations were administered with either buffered or non-buffered articaine. Subjective evaluation was done for pain on injection, pain during extraction using Wong-Baker Faces Pain Rating Scale (WBFPR) and onset of anesthesia in seconds. Pain on injection, pain during extraction were objectively evaluated using Sound Eye Motor (SEM) scale and onset of anesthesia was also evaluated objectively by pricking with sharp dental probe. Results: The outcome was, significantly less pain on injection and significantly faster onset of anesthesia with significantly less pain during extraction for both subjective and objective evaluations in the buffered articaine group. Subgroup analysis was also performed and it showed variable results, with only significant difference for WBFPR scores in age subgroup 4-7 years for palatal infiltration. Conclusion: Less pain on injection, faster onset of anesthesia, and less pain during extraction were observed when buffered articaine was used for maxillary primary molar extraction.

천리안위성의 발사체와의 전자파 적합성 시험결과 분석 (RF Compatibility Test Results of COMS satellite with Launch Vehicle)

  • 최재동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.215-217
    • /
    • 2010
  • This paper describes the test results of radiated compatibility with Ariane 5 launcher performed on the COMS Satellite test facility. Firstly, the Radiated Emission test results are analyzed in compliance with the Radiated Susceptibility requirement specification of Ariane 5 launcher. The satellite nominal operation is monitored during injection a radiated electric field corresponding to the launcher emissions levels in critical frequency ranges. And also, E-field are measured through a probe located at external units level in order to assess the EMC safety margin in Radiated mode.

  • PDF

LPG엔진에서 이온프로브를 이용한 노킹 발생 위치 추정에 관한 연구 (Study on the Estimation of Knock Position in a LPG Engine with Ion-probe Head Gasket)

  • 이정원;최회명;조훈;황승환;민경덕
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.42-48
    • /
    • 2003
  • LPG has been a broad concern of pro-environmental alternative fuel for vehicles. Recently, the new Liquid Phase LPG Injection(LPLI) system extends the limit of power of LPG engine and gives a chance to substitute LPG engine for diesel engine of heavy duty vehicles that are the main resources of air pollution in urban area. Large bore size of heavy duty LPG engine derives a serious knock problem. To find an optimal MBT conditions, it is necessary to know how the flame develops in the combustion chamber and find where the knock positions are. In this study. the ion-probe head gasket was used to estimate the knock position. Inverse operation of the ion-probe signal provides the flame developing characteristics. The further the position is from the spark plug, the later the flame arrives and the more times knock occurs. The main factor that effects knock position is inferred a flor situation of mixed gas in the combustion chamber.

열적으로 강인한 Molybdenium 게이트-PMOS Capacitor의 분석 (Analysis of PMOS Capacitor with Thermally Robust Molybdenium Gate)

  • 이정민;서현상;홍신남
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.594-599
    • /
    • 2005
  • In this paper, we report the properties of Mo metal employed as PMOS gate electrode. Mo on $SiO_2$ was observed to be stable up to $900^{\circ}C$ by analyzing the Interface with XRD. C-V measurement was performed on the fabricated MOS capacitor with Mo Bate on $SiO_2$. The stability of EOT and work-function was verified by comparing the C-V curves measured before and after annealing at 600, 700, 800, and $900^{\circ}C$. C-V hysteresis curve was performed to identify the effect of fired charge. Gate-injection and substrate-injection of carrier were performed to study the characteristics of $Mo-SiO_2$ and $SiO_2-Si$ interface. Sheet resistance of Mo metal gate obtained from 4-point probe was less than $10\;\Omega\Box$ that was much lower than that of polysilicon.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

수질 모니터링을 위한 암모니아 분석 칩과 중금속 센서

  • 박준식;황길호;강성군
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.18.2-18.2
    • /
    • 2011
  • 생활수준이 향상되고, 환경오염이 가속되면서 환경에 대한 관심이 더욱 증대되고 있다. 수질센서의 경우, 그 측정 항목이 매우 다양하고, 높은 정밀도를 요하고 있을 뿐만 아니라 지속적인 실시간 모니터링을 요구하고 있어, 기술적으로 해결해야 할 문제가 많이 남아 있다. 또한, 현재 약 15% 정도로 매우 낮은 국산화율을 보이고 있어, 대부분의 주요 센서들이 수입에 의존하고 있는 실정이다. 수질을 측정하기 위한 센서는 크게 두 가지 형태로 나누어 질 수 있는데, 하나는 flow injection analysis (FIA) 방식이며, 다른 하나는 Probe 방식의 센서이다. 본 발표에서는 수질 센서에 대한 최근 국내 기술 동향과, 수질 모니터링을 위한 Lab-on-a-chip 형 암모니아 분석 칩, Probe 형 중금속 센서 연구 개발 결과를 요약하고자 한다. 암모니아 분석 칩은 마이크로 유체 소자 내에서 Berthelot reaction을 유도하고, 흡광법에 의하여 물 속에 존재하는 암모니아를 간접적으로 측정하는 방법이다. 또한, 중금속 센서로 일반적인 working electrode 소재로 사용되는 독성이 있는 Hg 보다 친환경적인 개발된 bismuth-modified carbon nanotube와 같은 Bi계 복합소재를 적용하여 물 속에 존재하는 저 농도의 Pb, Cd, Zn을 측정 분석할 수 있었다. 본 연구를 통해 개발된 분석칩과 중금속 센서를 이용하여 하천에서 샘플링된 물에서의 암모니아 및 중금속 농도를 각각 분석할 수 있었다.

  • PDF

Determination of Heparin Using Norfloxacin-cerium Complex as a Fluorescence Probe by Spectrofluorimetry

  • Patil, Shailaja R.;Mote, Umesh S.;Patil, Shivajirao R.;Kolekar, Govind B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권12호
    • /
    • pp.3034-3038
    • /
    • 2009
  • A simple, rapid, practical and sensitive spectofluorimetric method was developed for the determination of trace amount of heparin (Hep). Under the Optimum conditions, we studied the interaction between NFLX-Ce$^{3+}$-Hep complex by using absorption and fluorescence spectra. It was observed that Hep remarkably enhance the fluorescence intensity of the NFLX-Ce$^{3+}$ complex at ${\lambda}$= 356 nm in the buffer solution of pH = 7.60 and the enhancement effect is shown to relate with the concentration of Hep. The linear range and detection limit for the determination of Hep was obtained. By the Rosenthal graphic method, the association constant (K) and binding numbers (N) of Hep with probe were investigated. This method is relatively free of interference from coexisting substances and successfully applied for the determination of heparin in heparin sodium injection samples. A suitable mechanism of fluorescence enhancement between NFLX-Ce$^{3+}$ and the NFLX-Ce$^{3+}$-Hep systems were proposed and discussed.

ECR-PECVD 장치의 제작과 특성 (Manufacturing and characterization of ECR-PECVD system)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF