• Title/Summary/Keyword: injection detection

Search Result 487, Processing Time 0.023 seconds

A Welding Defect Inspection using an Ultrasound Excited Thermography (초음파 서모그라피를 이용한 용접 결함 검사)

  • Jo Jae-Wan;Jeong Jin-Man;Choi Yeong-Su;Jeong Seung-Ho;Jeong Hyeon-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.148-150
    • /
    • 2006
  • In this paper, the applicability of an UET(ultrasound excited thermography) for a defect detection of the welded receptacle is described. An UET(ultrasound excited thermography) is a defect-selective and fast imaging tool for damage detection. A high power ultrasound-excited vibration energy with pulse durations of 280ms is injected into the outer surface of the welded receptacle made of Al material. An ultrasound vibration energy sent into the welded receptacle propagate inside the sample until they are converted into the heat in the vicinity of the defect. The injection of the ultrasound excited vibration energy results in heat generation so that the defect is turned into a local thermal wave transmitter. Its local heat emission is monitored by the thermal infrared camera. And they are processed by the image recording system. Measurement was performed on aluminum receptacle welded by using Nd:YAG laser. The observed thermal image revealed two area of defects along the welded seam.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

Development of System For Cell Fusion Detection (세포 전기 융합 감지 장치에 관한 연구)

  • Kwon, Ki-Jin;Kim, Min-Soo;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

Fabrication of Microcantilever-based Biosensor Using the Surface Micromachining Technique (표면 미세 가공기술을 이용한 마이크로 캔틸레버의 제작과 바이오센서로의 응용)

  • Yoo Kyung-Ah;Joung Seung-Ryong;Kang C. J.;Kim Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.11-15
    • /
    • 2006
  • We propose an optical and an electrical detection methods for detecting various bio-molecules effectively with microcantilevers. The microcantilevers were fabricated employing surface micromachining technique that has attractive advantages in terms of cost efficiency, simplicity and ability of fabricating in array. The fluid cell system for injection of bio-molecular solution is fabricated using polydimethylsiloxane (PDMS) and a fused silica glass. The microcantilever is deflected with respect to the difference of the surface stress caused by the formation of self-assembled bio-molecules on the gold coated side of the microcantilever. It detected cystamine dihydrochloride and glutaraldehyde molecules and analyzed individual concentrations of the cystamine dihydrochloride solution. We confirm that the deflections of bending-up or bending-down are occurred by the bio-molecule adsorption and microcantilever can be widely used to a ${\mu}-TAS$ and a lab-on-a-chip for a potential detection of various bio-molecules.

Determination of Pd(II) and Pt(II) Metal Cyano Complexes Using Capillary Electrophoresis

  • Lee, Hue-Jin;Lee, Sang-Ho;Chung, Koo-Soon;Lee, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.945-949
    • /
    • 1994
  • Mixtures of cyano complexes of palladium(II) and platinum(II) were separated by capillary electrophoresis using a fused silica capillary as a separation column and 30 mM phosphate buffer (pH 7) containing 15 wt. % acetonitrile as a running buffer. By virtue of the high ionic mobilities of the negatively charged cyano complexes of Pd(II) and Pt(II), they were separated using a cathodic injection and anodic detection scheme. The metal complexes eluted through the capillary were detected by direct UV absorption at 214 nm. A linear relationship between peak area and concentration was obtained for both ions and the detection limit was lower than $10^{-14}$ mole. The proposed method was applied to real sample, e.g., anode slime obtained from an electrolytic copper refinary, as a method for the simultaneous determination of palladium and platinum.

A Study on The Design of The Self-Checking Comparator Using Time Diversity (시간 상이점을 이용한 자체 검진 비교기의 설계에 관한 연구)

  • 신석균;양성현;이기서
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.270-279
    • /
    • 1998
  • This paper presents the design of self-checking comparator using the time diversity and the application to 8 bit CPU for the implementation of fault tolerant computer system. this self-checking comparator was designed with the different time Points in which temporary faults were raised by electrical noise between duplicated functional blocks. also this self-checking comparator was simulated in the method of the fault injection using 4 bit shift register counter. we designed the duplicated Emotional block and the self-checking comparator in the single chip using the Altera EPLD and could verify the reliability and the fault detection coverage through the modeling of temporary faults ,especially intermittent faults. at the results of this research, the reliability and the fault detection coverage were implemented through the self-checking comparator using the time diversity.

  • PDF

Start Point Detection Method for Tracing the Injection Path of Steel Rebars (철근 사출 궤적 추적을 위한 시작지점 검출 방법)

  • Lee, Jun-Mock;Kang, Dae-Seong
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.6
    • /
    • pp.9-16
    • /
    • 2019
  • Companies that want to improve their manufacturing processes have recently introduced the smart factory, which is particularly noticeable. The ultimate goal is to maximize the area of the smart factory that performs the process of the production facility completely with minimal manual control and to minimize errors of reasoning. This research is a part of a project for unmanned production, management, packaging, and delivery management and the detection of the start point of rebars to perform the automatic calibration of the rollers through the tracking of the automated facilities of unmanned production. It must meet the requirement to accurately track the position from the start point to the end point. In order to improve the tracking performance, it is important to set the accurate start point. However, the probability of tracking errors is high depending on environments such as illumination and dust through the conventional time-based detection method. In this paper, we propose a starting point detection method using the average brightness change of high speed IR camera to reduce the errors according to the environments, As a result, its performance is improved by more than 15%.

A Simulation Study on the Development of Injection Mold for the Parts of Phone Camera Lens Module (시뮬레이션을 활용한 폰카메라 렌즈모듈 부품용 사출금형개발)

  • Kim, Hye Jeong;Kim, Jae Hoon;Kim, Yeong Gyoo;Song, Jun Yeob;Moon, Dug Hee
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.4
    • /
    • pp.83-92
    • /
    • 2013
  • The demand of a camera-lens-module which is installed in mobile phone has been increased explosively as the increase of mobile phone market. Recently, two missions are given to the parts manufacturer of lens module, and they are how to keep the quality of injection moulding process as the increase of resolution, and how to decrease manufacturing cost. In this paper, a simulation study is introduced which is used for developing barrel and shield considering the double-cassette type of mould. At first, the simulation for injection process using Mold Flow$^{TM}$ is applied in the phase of mould design, and mechanical simulation using DPM Assembly$^{TM}$ is applied for collision detection between picking robot and mould. As a result, the productivity increased more than 300%.

A Study on the Determination of$N(NO_2^-),\;N(NO_3^-)$and$N(NH_4^+)$in Environmental Samples by Flow Injection Analysis (흐름주입분석법에 의한 환경시료 중$N(NO_2^-),\;N(NO_3^-)$$N(NH_4^+)$의 정량분석에 관한 연구)

  • Rhee, Jae Seong;Kim, Young Sang;Jung, Yun Hee;Rhee, Hee Jung
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.5
    • /
    • pp.256-265
    • /
    • 1997
  • A rapid and sequential method was studied, which can determine nitrite, nitrate and ammonium ion in soil or water samples with flow injection analysis. Geometric factors including injection volume, length of the reaction coil and flow rate of carrier solution were investigated prior to sample measurement. Nitrite was determined at 540 nm by Griess reaction producing azo dye between N-(1-naphthylethylenediamine dihydrochloride) and sulfanilamide. Nitrate was also measured under the help of reduction mechanism toward nitrite with hydrazine. Ammonium was analyzed at 440 nm with Nessler's reagent. At the optimum condition, the detection limit(S/N=3) has been shown 0.1 ㎍/mL N(NO2-), 0.4 ㎍/mL N(NO3-) and 0.3 ㎍/mL N(NH4+) respectively. The results measured by colorimetry, ion chromatography and FIA were compared showing 80%-125% reasonable match each other. Injection throughput rate could be performed better than 30 times per hour.

  • PDF

Effect of Gonadotropin Administration on Blood Ovarian Steroid Hormone Level in Rabbit (성선자극 호르몬 투여가 토끼의 혈중 난소 스테로이드호르몬 수준에 미치는 영향)

  • 김병기
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.4
    • /
    • pp.363-371
    • /
    • 1997
  • The present study was carried out to investigate the effect of gonadotropin administration on blood ovarian steroid hormone in angora rabbit. Mature angora rabbits were primed for superovulation with PMSG 100IU. Eighty hours later, the rabbit were induced to ovulate with HCG 100IU. In exp 1, blood progesterone and estradiol of superovulated does were measured by radiommunoassay. Blood progesterone concentration at 93, 99, 102 and 114 hours after HCG injection were 12.9$\pm$0.5, 34.8$\pm$5.1, 12.2$\pm$2.7 and 43.4$\pm$5.8ng/ml, respectively. Mean progesterone concentration of blood collected at 99 and 114 hours after HCG injection(p<0.05). However, mean blood estradiol concentration was not changed. In exp 2, superovulated does were unilaterally ovariectomized at 96 hours after HCG injection. Blood progesterone concentration was tend to be decreased after ovariectomy. Nosignificant changes in blood estradiol concentration was observed after ovariectomy. In exp 3, superovulated does were bilaterally ovariectomized at 96 hours after HCG injection Ovariectomized does were treated with progesterone. Blood progesterone level in the rabbits treated, twice daily, with 5mg progesterone after ovariectomy was similiar to that in the superovulated intact rabbits. Blood estradiol concentration of the rabbits after bilateral ovariectomy was beyond detection range. Blood progesterone concentration was significantly decreased to 7.6$\pm$3.0ng/ml wi thin 3 hours after ovriectomy(p<0.05). However, that value was increased to 34.8$\pm$8.2ng/ml by 5 mg progesterone treatment and this elevated level was significatnly decreased to 7.3$\pm$2.4ng/ml at 12 hours after progesterone administration(p<0.05).

  • PDF