• Title/Summary/Keyword: inhalation

Search Result 1,011, Processing Time 0.038 seconds

Cardiopulmonary Effects of Enflurane Combined with Propofol in Dogs (개에서 Enflurane과 Propofol의 병용이 심폐기능에 미치는 영향)

  • Chae, Hyung-gyu;Jang, Kwang-ho;Jang, In-ho
    • Journal of Veterinary Clinics
    • /
    • v.18 no.3
    • /
    • pp.249-256
    • /
    • 2001
  • This study was performed to evaluate cardiopulmonary depressant effects of enflurane (1.0 vol%) combined with propofol(0.25 mg/kg/min) compared with enflurane inhalation, and propofol infusion, respectively, in 18 healthy dogs premedicated with acepromazine and atropine. After bolus injection of propofol 5 mg/kg for induction and tracheal intubation, they were randomly assigned to 3 groups: propofol 0.5 mg/kg/min infusion (Group I, n=6), enflurane 2.5 vol% (Group II, n=6) and enflurane 1.0 vol% combined with propofol 0.25 mg/kg/min (Group III, n=6). Mean arterial Pressure (MAP), systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) were depressed significantly in all groups, especially in Group II. MAP, SAP and DAP values of Group IIIwere higher than those of Group II, but lower than those of Group I. The changes of PaO$_2$, Pa$CO_2$and pHa were similar in all groups. Respiration rates were decreased in all groups 5 minutes after induction but maintained in normal range. Those of Group I were less depressant than those of Group II and Group III. Concentrations of $Na^+ and Cl^-$ were increased and those of $K^+$ were decreased in all groups, but their values were quitely similar. Heart rate was changed in small range and the value of Group I was higher than those of Group II and Group III. Body temperature was decreased significantly in all groups. Adverse effects like as muscle rigidity, nausea or vomiting and shivering were not appeared and apnea at induction was occured 6 dogs. From the these results, enflurane 1.0 vol% combined with propofol 0.25 mg/kg/min also could be applied for anesthesia in dogs.

  • PDF

THE EFFECTIVENESS OF TWO SEDATIVE REGIMEN USED FOR CHILD PATIENT WHO FAILED TO ORAL CHLORAL HYDRATE (Chloral hydrate 경구 진정에 실패한 소아환자를 대상으로 사용한 두 가지 진정요법의 효과)

  • Lee, Sang-Min;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.505-516
    • /
    • 2000
  • Chloral hydrate is one of the most widely used sedative agents to control the difficult-to-treat young age group in the dental clinic. We are often frustrated to see the patient still awake and cry with agitation even after far more than the normal onset time of Chloral hydrate. In such a case, the patient has to be rescheduled for another sedation visit with different agents and/or routes which greatly disappoints the guardians. This study was designed to test the efficacy of one sedative regimen that can possibly help the clinician complete scheduled treatment without postponement. We have tried sleep induction with mixed gas of Enflurane(2vol%) and $N_2O(50%)-O_2(50%)$ for $60\sim120$ seconds to 35 patients of those who failed to respond properly to the dose(70mg/kg)of oral Chloral hydrate. The Result of this regimen was compare to those of two oral regimen of Chloral hydrate/Hydroxyzine and Chloral hydrate only Analyses of result on vital signs and behavior pattern were performed. The outcome of the study suggest that sleep induction by a short inhalation of low dose of $Enflurane/N_2O-O_2$ provide dentist with suitable condition for the completion of scheduled treatment in the patient who failed to oral Chloral hydrate. Evidence of adverse effect was not detected or reported during and/or after the procedures.

  • PDF

The Protective Effect of Inhaled Heparin, Cromolyn, Budesonide, and Furosemide on Exercise-induced Asthma (운동유발성 천식의 기관지 수축에 대한 Heparin, Cromolyn, Budesonide, Furosemide 흡입 치료의 효과)

  • Lee, Sin-Hyung;Shim, Jae-Jeong;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1188-1198
    • /
    • 1998
  • Background : The purpose of the present study was to determine the protective effect of antiasthmatic activity of inhaled heparin, cromolyn sodium, budesonide, furosemide in exercise-induced asthma(EIA). The other important considerable point of this study was the mechanism of bronchoconstriction on EIA. Methods : Eight subjects with a history of EIA were studied on 5 different experiment days. After obtaining baseline $FEV_1$ and FVC, subjects performed a standardized exercise challenge. EIA was assessed by measurement of $FEV_1$ before and after exercise. On experiment day 4, the exercise challenge was performed after the subjects inhaled either heparin (1,000 units/kg/day for 5 days), furosemide (1mg/kg for 5 days), cromolyn (4mg/day for 5 days), or budesonide ($400{\mu}g/day$ for 5 days). On experiment day 5, the methacholine bronchial provocation test was performed. On experiment day 3, activated partial thromboplastine time(aPTI) was checked. Results : Maximum decrements of $FEV_1$ (mean${\pm}$SE) among 0 to 120 minutes after exercise were as follows : heparin was $83.1{\pm}4.81%$ (p=0.010), furosemide was $80.5{\pm}6.87%$ (p=0.071), cromolyn was $86.8{\pm}6.53%$ (p=0.340), and budesonide was $79.4{\pm}7.31%$ (p=0.095). Above medications were compared to the control value ($72.5{\pm}18.2%$) by paired t-test. No medications had effect on $PD_{20}$ of methacholine bronchial provocation test The results were control $1.58{\pm}0.49{\mu}mol$), heparin ($4.17{\pm}1.96{\mu}mol$), furosemide ($1.85{\pm}0.86{\mu}mol$), cromolyn ($2.19{\pm}0.89{\mu}mol$), and budesonide ($3.38{\pm}1.77{\mu}mol$), respectively(p>0.05). The inhaled heparin had no effect of anticoagulation. Conclusion : These data demonstrate that inhaled heparin has a protective effect on EIA. The effect of inhaled cromolyn was statistically absent with manufacture's recommended dosage on EIA. So, the dosage of cromolyn should be carefully evaluated in future. Although inhalation of budesonide and furosemide have no statistical significance compared to control, these drugs also have some protective effects on EIA.

  • PDF

Gender Differences of Susceptibility to Lung Cancer According to Smoking Habits (흡연습관에 따른 폐암발생 감수성에 대한 성별의 차이)

  • Choi, Chung-Kyoung;Shin, Kyeong-Cheol;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.576-584
    • /
    • 2000
  • Background : With the increase of cigarette consumption by women and the young, the incidence of lung cancer is expected to increase during the next three or four decades in Korea. The purpose of this study was to analyze the smoking habits in patients with lung cancer and to identify the gender differences in terms of their susceptibility to cigarette related carcinogens. Method : This investigation was a hospital-based case control study, which included the data of 178 case subjects (72 females, 106 males) with lung cancer and 218 control subjects (97 females, 121 males) with diseases unrelated to smoking. The information was obtained through a direct personal interview and a questionnaire related to personal smoking history. Results : The relative frequency of the squamous cell carcinoma was substantially higher in males than in females (61.3% in males, and 29.2% in females), while adenocarcinoma including bronchoalveolar cell carcinoma was higher in females(31.9% in females, 18.9% in males). Kreyberg I lung cancer was of relatively higher frequencies in males and smokers, while Kreyberg II lung cancer was higher in females and never smokers. The odds ratios (ORs) at each exposure level were consistently higher in females than males. For all cell types, the risk of lung cancer was increased with the quantity of smoked cigarettes, duration of smoking, and depth of inhalation. Odds ratio was distinctly higher in Kreyberg I lung cancer than in total lung cancer and a steeper gradient of risk with increased smoking was observed in females. Conclusion : The relative risk for lung cancer was consistently higher in females than in males at every level of exposure to cigarette smoke. This is believed to be due to the higher susceptibility of females to tobacco carcinogens, such as gender associated differences of carcinogen activation and/or the elimination of smoking related metabolites.

  • PDF

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Clinical investigation of lipoid pneumonia in adults (성인에서 발생한 지방성 폐렴의 임상적 고찰)

  • Hyun, Jae Geun;Rhee, Chong H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.965-975
    • /
    • 1996
  • Background : Exogenous lipoid pneumonia is caused by inhalation or aspiration of animal, vegetable or mineral oil. Most cases are ascribed to aspiration of oil in laxatives or nose drops Petroleum, another pure hydrocarbon used as a base in various medications, is occasionally involved. Especially animal oil produces severe tissue inflammatory reaction, but most patients present with only abnormal chest X-ray and no specific clinical symptoms or signs. Method: Seven patients, 3 males and 4 females, with exogenous lipoid pneumonia, who was hospitalized or referred to pulmonary division at Samsung Medical Center from December 1994 10 July 1996, were included. They hadn a history of laking shark liver oil(so-called "squalene") for varying period of time. We reviewed clinical, radioloic and pathologic findings. Result: Patients look 7 to 30 capsules of "squalene" a day for at least one month to 5 years. Six cases had chronic disease such as diabetes, hypertension, or cerebrovascular accident. Respiratory symptoms of mild fever, cough and sputum were present in 3 cases and in 3 cases there was no clinical symptoms and signs but abnormal findings by chest X - ray. The major radiologic findings by simple chest X - ray and computed tomography consisted of consolidation, infiltration involving mainly right middle and both lower lobes, and ground-glass opacity. Five of six bronchoscopic examinations demonstrated both lipid droplets floating on the surface of bronchoalveolar lavage fluid and Lipid-laden macrophages in bronchoalveolar lavage fluid or lung tissue. Follow-up chest X -ray showed improvement in 4 cases but no marked interval change in 3 cases after removal of exposure to "squalene". Conclusion: Shark liver oil can induce lipoid pneumonia in adults. In case of high clinical suspicion, confirmation of "squalene" use by careful history taking is required and bronchoscopy is helpful in diagnosis.

  • PDF

Simultaneous Analysis of 13 Pesticides in Groundwater and Evaluation of its Persistent Characteristics

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Kim, Ki-In;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-hyun;Lee, Gyeong-Mi;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.434-451
    • /
    • 2017
  • For this study, groundwater samples for 3 years from 2011 through 2013 were collected at 106 groundwater monitoring site in Korea. These groundwater samples were analyzed for 13 pesticides such as cabofuran, pentachlorobenzene, hexachlorobenzene, simazine, atrazine, lindane (gamma-HCH), alachlor, heptachlor, chlordane (total), endosulfan (1, 2), dieldrin, endrin, 4,4-DDT. The objectives of this study were to determine the detection frequency and their concentrations of 13 pesticides and evaluate the health risk level considering ingestion, inhalation, and skin contact using concentrations of 13 pesticides in groundwater samples. An analysis was used for the simultaneous determination for 13 pesticides using GC-MS. GC-MS was performed on HP-5ms, using helium ($1ml\;min^{-1}$) as carrier gas. The average recoveries of the pesticides were from 92.8% to 120.8%. The limits of detection (LODs) were between $0.004{\mu}g\;L^{-1}$ and $0.118{\mu}g\;L^{-1}$ and the limits of quantification (LOQs) were between $0.012{\mu}g\;L^{-1}$ and $0.354{\mu}g\;L^{-1}$. 106 groundwater wells were selected. 54 wells were from well to monitor background groundwater quality and 52 wells were from well to monitor groundwater quality in industrial or contamination source area. Eight pesticides including pentachlorobenzene, lindane (Gamma-HCH), heptachlor, chlordane (total), Endosulfan (1, 2), dieldrin, endrin, and 4,4-DDT were not detected in groundwater samples. The detection frequency for hexachlorobenzene, alachlor, carbofuran and simazine was 23.4%, 11.4%, 7.3%, and 1.0%, respectively. Atrazine was detected once in 2011. The average concentrations were $0.00423{\mu}g\;L^{-1}$ for carbofuran, $0.000243{\mu}g\;L^{-1}$ for alachlor, $0.00015{\mu}g\;L^{-1}$ for simazine, and $0.00001{\mu}g\;L^{-1}$ for hexachlorobenzene. The detection frequency of hexachlorobenzene was high, but the average concentration was low. In the contaminated groundwater, the detection frequency for hexachlorobenzene, alachlor, carbofuran, simazine and atrazine was 26.1%, 21.3%, 7.1%, 1.9% and 0.3%, respectively. In the uncontaminated groundwater, detection frequency for hexachlorobenzene, carbofuran and alachlor were 20.2%, 7.5%, and 1.9% respectively. Simazine and atrazine were not detected at uncontaminated groundwater wells. According to the purpose of groundwater use, atrazine was detected for agricultural groundwater use. Hexachlorobenzene showed high detection frequency at agricultural groundwater use area where the animal feeding area and golf course area were located. Alachlor showed more than 50% detection frequency at cropping area, pollution concern river area, and golf course area. Atrazine was detected in agricultural water use area. By land use, the maximum detection frequency of alachlor was found near an orchard. For human risk assessment, the cancer risk for the 5 pesticides was between $10^{-7}$ and $10^{-10}$, while the non-cancer risk (HQ value) was between $10^{-4}$ and $10^{-6}$. For conclusion, these monitoring study needs to continue because of the possibility of groundwater contamination based on various purpose of groundwater use.

Effect of Inhaled Steroids on the Cortisol Concentration by Different Dosage or Delivery Method (흡입성 스테로이드 제제의 투여용량 및 방법이 기저 코르티솔농도에 미치는 영향)

  • Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.888-899
    • /
    • 1995
  • Background: Topical inhaled steroids, budesonide(Bu) and beclomethasone dipropionate (BOP), are now established as effective drugs in the management of chronic asthma. These drugs have high topical anti-inflammatory effect with low systemic activity. This study was performed to determine the effects of two inhaled corticosteroids, Bu and BOP, on the adrenocortical supression in 44 patients with bronchial asthma or chronic obstructive pulmonary disease. Methods: The adrenocortical function was assessed by measurement of serum cortisol concentration at 8 o'clock in morning and free cortisol in 24-hour urine collection at interval in 44 patients. No steroid was administered during the pretreatment period of 10 days and the final 6 days of the study. Each subject inhaled BOP or Bu, in daily doses of 800 or 1,600 micrograms for 12 days. The dose was delivered by metered dose inhaler (MDI) or diskhaler or large spacing device attached to MDI. Results: The levels of serum cortisol and 24-hour urinary free cortisol were decreased during the treatment period in patients inhaled Bu delivered by MDI in daily doses of 800 and 1,600 micrograms. In contrast, serum cortisol level was decreased on 6 and 12th day of treatment period in patients with BDP diskhaler in daily doses of 800 micrograms. In daily doses of 1,600 micrograms, the serum cortisol and 24hour urine free cortisol levels were decreased on 6, 9 and 12th day of treatment period in patients with BDP disk haler. The serum cortisol and 24-hour urinary free cortisol levels were not significantly decreased during the treatment period in patients inhaled Bu delivered by large spacing device attached to a MDI. Conclusion: These results showed that 1) the endogenous cortisol secretion was suppressed after inhalation of BDP and Bu in daily doses of 800 and 1,600micrograms, 2) Bu with MDI suppressed the adrenocortical function more than BDP with diskhaler, in daily doses of 1600 micrograms. and 3)large spacing device attached to a MDI might decrease the risk of suppression in the hypothalamic -pituitary- adrenal axis.

  • PDF

Clinical Significance of Plasma TGF-${\beta}_1$ in Coal Workers' Pneumoconiosis (탄광부 진폐증에서 혈장 Transforming Growth Factor-${\beta}_1$의 의의)

  • Kim, Chong-Ju;Lee, Won-Yeon;Hong, Ae-Ra;Shin, Pyo-Jin;Yong, Suk-Joong;Shin, Kye-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.76-83
    • /
    • 2001
  • Background : Coal workers' pneumoconiosis is a fibrotic lung disease resulting from chronic inhalation of coal dust. The precise mechanism of lung fibrosis in coal workers' pneumoconiosis is uncertain. However, a relationship between the stimulation of fibroblast proliferation and collagen production by mediators released from in flammatory and resident lung cells is thought to be a major factor. The transforming growth factor-$\beta$(TGF-$\beta$), a multifunctional cytokine and growth factor, plays a key role in the scarring and fibrotic processes due to its ability to induce extracellular matrix proteins and modulate the growth and immune function of many cell types. To determine the involvement of TGF-$\beta$ in the development of lung fibrosis in coal workers' pneumoconiosis, the TGF-${\beta}_1$ level in plasma was measured in patients with coal workers' pneumoconiosis. Methods : Plasma was collected from 40 patients with coal workers' pneumoconiosis (20 with simple coal workers' pneumoconiosis and 20 with complicated coal workers' pneumoconiosis) and from 10 normal controls. The ELISA method was used to measure the plasma TGF-${\beta}_1$ concentration. Results : Compared to the control group ($0.63{\pm}01.8$ ng/mL), there was no significant difference in the plasma TGF-${\beta}_1$ level in patients with simple coal workers' pneumoconiosis ($0.64{\pm}0.17$ ng/mL) (p>0.05). However, in patients with complicated coal workers' pneumoconiosis the plasma TGF-${\beta}_1$ level ($0.79{\pm}0.18$ ng/mL) was significantly higher than in patients with simple coal workers' pneumoconiosis and the control group (p<0.05). Conclusion : The data suggests that TGF-${\beta}_1$ has some influence in the development of lung fibrosis in coal workers' pneumoconiosis.

  • PDF

Relationship between Bronchial Sensitivity and Bronchial Reactivity in Asthma (기관지천식 환자에서 기관지 감수성과 기관지 반응성에 관한 연구)

  • Seo, Ki-Youl;Chang, Jung-Hyun;Cheon, Seon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.341-350
    • /
    • 1998
  • Background: Airway hyperreponsiveness is a cardinal feature of asthma. It consists of both an increased sensitivity of the airways, as indicated by a smaller concentration of a constrictor agonist needed to initiate the brochoconstrictor response and an increased reactivity, increments in response induced subsequent doses of constrictor, as manifested by slopes of the dose-response curve. The purpose of this study is to observe the relationship between bronchial sensitivity and reactivity in asthmatic subjects. Method: Inhalation dose-response curves using methacholine were plotted in 56 asthmatic subjects. They were divided into three groups(mild, moderate and severe) according to clinical severity of bronchial asthma. PC20 were determined from the dose-response curve as the provocative concentration of the agonist causing a 20% fall in FEVl. PC40 were presumed or determined from the dose response curve, using the PC20 and the one more dose after PC20. Reactivity was calculated from the dose-response curve regression line, connecting PC20 with PC40. Results: PC20 were 1.83mg/ml in mild group, 0.96mg/ml in moderate, and 0.34mg/ml in severe. PC40 were 7.l7mg/ml in mild group, 2.34mg/ml in moderate, and 0.75mg/ml in severe. Reactivity were $24.7{\pm}17.06$ in mild group, $46.1{\pm}22.l0$ in moderate, and $59.0{\pm}5.82$ in severe. There was significant negative correlation between PC20 and reactivity (r= -0.70, P<0.01). Conclusion: Accordingly, there was significant negative correlation between bronchial sensitivity and brochial reactivity in asthmatic subjects. However, in some cases, there were wide variations in terms of the reactivity among the subjects who have similar sensitivity. So both should be assessed when the bronchial response tor bronchoconstrictor agonists is measured.

  • PDF