• Title/Summary/Keyword: infrared rays

Search Result 177, Processing Time 0.026 seconds

The effect of infrared rays diode irradiation on collagen formation (적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

IR Absorption Property in Nano-thick Nickel Silicides (나노급 두께 니켈실리사이드의 적외선 흡수 특성)

  • Yoon, Ki-Jeong;Han, Jeung-Jo;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.17 no.6
    • /
    • pp.323-330
    • /
    • 2007
  • We fabricated thermaly evaporated 10 nmNi/(poly)Si films to investigate the energy saving property of silicides formed by rapid thermal annealing (RTA) at the temperature of $300{\sim}1200^{\circ}C$ for 40 seconds. Moreover, we fabricated $10{\sim}50$ nm-thick ITO/Si films with a rf-sputter as reference films. A four-point tester was used to investigate the sheet resistance. A transmission electron microscope (TEM) and an X-ray diffractometer were used for the determination of cross sectional microstructure and phase changes. A UV-VISNIR and FT-IR (Fourier transform infrared rays spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM analysis, we confirmed $20{\sim}70nm-thick$ silicide layers formed on the single and polycrystalline silicon substrates. Nickel silicides and ITO films on the single silicon substrates showed almost similar absorbance in near-IR region, while nickel silicides on polycrystalline silicon substrate showed superior absorbance above 850 nm near-IR region to ITO films. Nickel silicide on polycrystalline substrate also showed better absorbance in middle IR region than ITO. Our result implies that nano-thick nickel silicides may have exellent absorbing capacity in near-IR and middle-IR region.

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

An Experimental Study on the Optical Separation of Highly Concentrated Sunlight (Hot mirror를 이용한 고밀도 태양광의 광분리에 관한 기초실험 연구)

  • Kim, Yeongmin;Mo, Yonghyun;Shin, Sangwoong;Oh, Seungjin;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.56-60
    • /
    • 2014
  • Highly concentrated sunlight obtained from a solar concentrator mounted on a solar tracker can be divided into the infrared and visible region before it is actually applied. That is, solar rays are directed toward a unit optically separating sunlight into the infrared and visible region by a hot mirror as they impinge on the surface of a secondary reflector. The Infrared rays can be utilized for thermoacoustic applications while visible rays can be utilized for indoor lighting. This work introduces the separation of two different kinds of light; sunlight and artificial light. As for the artificial light, its wavelength extended from 400m to 720m for the visible region and 620m to 940m for the infrared region. Comparatively, a series of tests performed on sunlight revealed its separation in the visible region from 460m to 680m whereas from 620m to 940m for the artificial light.

Design of 8-bit Single Slope ADC for Signal Processing of Multiple Image Sensors (다중 이미지 센서의 신호처리를 위한 8-bit Single Slope ADC 설계)

  • Lee, Jong-Cheol;Lee, Sang-Hoon;Kim, Jin-Tae;Park, Jae-Roul;Shin, Jang-Kyoo;Choi, Pyung
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.252-257
    • /
    • 2015
  • This paper proposes a single slope A/D converter (SSADC) that is possible to process the signal of the ultraviolet, visible and infrared rays with a single chip. And the proposed SSADC is a type of single channel ADC. In the conventional SSADC, it is possible to process the only one signal with a kind of the sensor because the speed of the operating frequency and the slope of ramp signal generated by the ramp generator are fixed. In order to improve the disadvantages, a ramp generator which has variable slope in ramp function is designed and $3{\times}1$ MUX(multiplexer) is adopted so that we can change the speed of the operating frequency and the slope of ramp signal. Therefore, the multiple signal processing of the wanted sensors can be possible. The designed circuit is layout by the $0.35-{\mu}m$ CMOS 2-poly 4-metal technology process and is checked through DRC and LVS tools.

FOREGROUND OF GAMMA-RAY BURSTS (GRBS) FROM AKARI FIS DATA

  • Toth, L. Viktor;Doi, Yasuo;Zahorecz, Sarolta;Agas, Marton;Balazs, Lajos G.;Forro, Adrienn;Racz, Istvan I.
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.113-116
    • /
    • 2017
  • A significant number of the parameters of a gamma-ray burst (GRB) and its host galaxy are calculated from the afterglow. There are various methods obtaining extinction values for the necessary correction for galactic foreground. These are: galaxy counts, from HI 21 cm surveys, from spectroscopic measurements and colors of nearby Galactic stars, or using extinction maps calculated from infrared surveys towards the GRB. We demonstrate that AKARI Far-Infrared Surveyor sky surface brightness maps are useful uncovering the fine structure of the galactic foreground of GRBs. Galactic cirrus structures of a number of GRBs are calculated with a 2 arcminute resolution, and the results are compared to that of other methods.

Development of an Optimum Void Detection Chart using Heat Transfer Simulation (열전달 시뮬레이션을 통한 최적공극탐지 차트개발)

  • Choi, Hyun-Ho;Park, Jin-Hyung;Ji, Goang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.241-244
    • /
    • 2006
  • It is essential to develop a large capacity, non-contact nondestructive inspection system having high reliability to investigate repaired and strengthened structures. Nowadays, an infrared camera is widely used in non-contact nondestructive inspection system. Because an infrared camera is sensitive to the surrounding environment, it is necessary to improve a sensitivity of thermal image information and a relationship between defects and thermal image information. In this papaer, presented is an optimum void detection chart for the optimum conditions to detect infrared rays from inside and outside defects like voids and cracks in concrete structures using extensive computer simulation. Sensitivity studies are performed with respect to variables influencing the temperature distribution such as heating temperature, heating time, and geometries of defect, etc. It may be stated that it could be successfully utilized for the non-contact nondestructive inspection system to detect defects in concrete structures.

  • PDF

Fabrication of Silicon Window for Low-price Thermal Imaging System (저가형 열영상 시스템을 위한 실리콘 윈도우 제작)

  • Sung, Byung Mok;Jung, Dong Geon;Bang, Soon Jae;Baek, Sun Min;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.

Optimization of sintering process of the far-infrared radiation ceramic (원적외선 방사 세라믹의 소결공정 최적화)

  • Park, Jae Hwa;Kim, Hyun Mi;Kang, Hyo Sang;Choi, Jae Sang;Choi, Bong Geun;Nam, Ki Woong;Nam, Han Woo;Shim, Kwang Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2016
  • Far-infrared radiation ceramic is an attractive material that provides thermal therapy by permeating the infrared rays into the deep inside of the human skin. Therefore, it is currently used for thermal therapy devices, thermal mat, heating equipment and so on. This work aims to optimize the sintering process of the far-infrared radiation ceramic with the process parameters of temperature and time. A variety of characterization tools have been used to investigate the optimal sintering condition of far-infrared radiation. The phase of far-infrared radiation ceramic was characterized by using X-ray diffraction (XRD) and microstructure of fracture surface was studied by scanning electron microscopy (SEM). The FT-IR was also performed to measure the far-infrared emissivity.

Image Processing Algorithms for DI-method Multi Touch Screen Controllers (DI 방식의 대형 멀티터치스크린을 위한 영상처리 알고리즘 설계)

  • Kang, Min-Gu;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.1-12
    • /
    • 2011
  • Large-sized multi-touch screen is usually made using infrared rays. That is because it has technical constraints or cost problems to make the screen with the other ways using such as existing resistive overlays, capacitive overlay, or acoustic wave. Using infrared rays to make multi-touch screen is easy, but is likely to have technical limits to be implemented. To make up for these technical problems, two other methods were suggested through Surface project, which is a next generation user-interface concept of Microsoft. One is Frustrated Total Internal Reflection (FTIR) which uses infrared cameras, the other is Diffuse Illumination (DI). FTIR and DI are easy to be implemented in large screens and are not influenced by the number of touch points. Although FTIR method has an advantage in detecting touch-points, it also has lots of disadvantages such as screen size limit, quality of the materials, the module for infrared LED arrays, and high consuming power. On the other hand, DI method has difficulty in detecting touch-points because of it's structural problems but makes it possible to solve the problem of FTIR. In this thesis, we study the algorithms for effectively correcting the distort phenomenon of optical lens, and image processing algorithms in order to solve the touch detecting problem of the original DI method. Moreover, we suggest calibration algorithms for improving the accuracy of multi-touch, and a new tracking technique for accurate movement and gesture of the touch device. To verify our approaches, we implemented a table-based multi touch screen.