• Title/Summary/Keyword: infrared detector

Search Result 320, Processing Time 0.026 seconds

A Study of Edge Detection for Auto Focus of Infrared Camera

  • Park, Hee-Duk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2018
  • In this paper, we propose an edge detection algorithm for auto focus of infrared camera. We designed and implemented the edge detection of infrared image by using a spatial filter on FPGA. The infrared camera should be designed to minimize the image processing time and usage of hardware resource because these days surveillance systems should have the fast response and be low size, weight and power. we applied the $3{\times}3$ mask filter which has an advantage of minimizing the usage of memory and the propagation delay to process filtering. When we applied Laplacian filter to extract contour data from an image, not only edge components but also noise components of the image were extracted by the filter. These noise components make it difficult to determine the focus state. Also a bad pixel of infrared detector causes a problem in detecting the edge components. So we propose an adaptive edge detection filter that is a method to extract only edge components except noise components of an image by analyzing a variance of pixel data in $3{\times}3$ memory area. And we can detect the bad pixel and replace it with neighboring normal pixel value when we store a pixel in $3{\times}3$ memory area for filtering calculation. The experimental result proves that the proposed method is effective to implement the edge detection for auto focus in infrared camera.

Materials Characterization Using A Novel Simultaneous Near-Infrared/X-ray Diffraction Instrument

  • Yeboah, S.Agyare;Blanton, Thomas;Switalski, Steve;Schuler, Julie;Analytical, Craig Barnes
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1288-1288
    • /
    • 2001
  • X-ray powder diffraction (XRD) is utilized for determination of polymorphism in crystalline organic materials. Though convenient to use in a laboratory setting, XRD is not easily adapted to in situ monitoring of synthetic chemical production applications. Near-Infrared spectroscopy (NIR) can be adapted to in situ manufacturing schemes by use of a source/detector probe. Conversely, NIR is unable to conclusively define the existence of polymorphism in crystalline materials. By combining the two techniques, a novel simultaneous NIR/XRD instrument has been developed. During material's analysis, results from XRD allow for defining the polymorphic phase present, and NIR data are collected as a fingerprint for each of the observed polymorphs. These NIR fingerprints will allow for the development of a library, which can be referenced during the use of a NIR probe in manufacturing settings.

  • PDF

Novel control scheme for the absence of the thermoelectric(TEC) of infrared detector in an Uncooled thermal system (비냉각 열상시스템에서의 적외선 검출기의 열전소자(TEC) 부재에 대한 효율적인 제어기법)

  • Kim, Yong-Jin;Seo, Jae-Gil;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2335-2340
    • /
    • 2012
  • The detector is an uncooled detector system that functions inside the thermoelectric cooler (TEC) equipped with features instead of the cooler. The function of the thermoelectric device to control the temperature of the detector based on a function of temperature to prevent degradation of image quality to perform the role, the latest technology trend by removing the thermoelectric device size, cost a lot of effort to reduce has been studied. In this paper, It would be proposed of the actual test result using real chamber environment of for the best TECless algorithm as to minimize the degradation of image quality and obtain the low price of the uncooled detector.

A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof (방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Jo, Young-Do;Kwon, Jeong-Rock;Ahn, Sang-Guk;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we developed an explosion proof type and portable combustible gas leak detector and proposed an algorithm to improve the accuracy for measuring gaseous concentrations. The nation's first we developed an infrared gas leak detector with explosion proof standard(Ex d ib) and improved measuring accuracy by using linearization recursion equation and 2nd Lagrange interpolation polynomial. Together, we advanced their performances and added their easy functions after investigating field demands. To compare our and other company's detectors, we performed measurement tests with eight standard gases made by Korea Gas Safety Corporation. We demonstrated the excellence of our instruments in measuring accuracy other than detecters through experimental results.

Development and Properties of Carbon monoxide Detector for Ambient Air monitoring (대기오염 측정용 일신화 탄소 검출기의 제작 및 특성)

  • Cho, Kyung-Haeng;Lee, Sang-Wha;Lee, Joung-Hae;Choi, Kyong-Sik
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.222-228
    • /
    • 2000
  • A detector for monitoring carbon monoxide (CO) in ambient air by nondispersive infrared (NDIR) spectroscopy has been developed and investigated its sensitivity and stability. The essential parts of the absorption cell are three spherical concave mirrors so as to improve the sensitivity by increasing the light path length in the cell. The radius and center of curvature of mirrors and position in the cell was calculated by computer simulation in order that the light path length may be 16m into the 50cm cell. The number of traversals and optical path properties were confirmed by laser beam alignment in transparent absorption cell. The photoconductive type lead selenide (PbSe) was used as CO sensing material, which was cooled to increase the responsibility by thermoelectric cooling method. The detection limit and span drift of the developed CO detector was 0.24ppm and 0.03ppm(v/v) respectively.

  • PDF

Implementation of BSCT $320{\times}240$ IR-FPA for Uncooled Thermal Imaging System (비냉각 열 영상 시트템용 BSCT $320{\times}240$ IR-FPA의 구현)

  • Kang, Dae-Seok;Shin, Gyeong-Uk;Park, Jae-U;Yoon, Dong-Han;Song, Seong-Hae;Han, Myeong-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.7-13
    • /
    • 2002
  • BSCT 320${\times}$240 IRFPA detector module is implemented, which is a key component in uncooled thermal imaging systems. The detector module consists of two parts, infrared sensitive pixel array and read-out integrated circuit(ROIC). The BSCT 320${\times}$240 pixels are made by laser scribe process and 10-${\mu}m$ micro-bump to satisfy 50-${\mu}m$ pitch and 95-% fill-factor. The ROIC has been designed to electrically address the pixels sequentailly and to improve signal-to-noise ratio with single transistor amplifier, HPF, tunable LPF and clamp circuit. The fabricated hybrid chip of detector and ROIC has been mounted on the TEC built-in ceramic package for more stable operation and tested for lots of electrical and optical properties. The IRFA sample has shown successful properties and met with good results of fill-factor, detectivity and responsivity.

Full Aperture Black Body Design, Fabrication and Validation for Infrared Detector Calibration (적외선 검출기 검보정을 위한 대구경흑체 설계, 제작 및 검증)

  • Cho, Hyokjin;Seo, Hee-Jun;Kim, Keun-Shik;Park, Sung-Wook;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • Satellite's infrared detector shall be calibrated under thermal vacuum environment using a reference black body before a launch. The full aperture black body (FABB) as an infrared calibration reference shall be composed of vacuum compatible materials and temperature controlled from $-40^{\circ}C$ to $+40^{\circ}C$ with emissivity higher than 0.95. The temperature homogeneity over the central 80 % area of the FABB front surface shall be better than 2 K. The FABB designed by thermal and flow analysis was $1m{\times}1m{\times}8mm$ copper plate on which black painted aluminum honeycomb core was attached. Copper tubes were welded on the opposite side of the honeycomb core to allow temperature regulated gaseous nitrogen to flow through them. By the FABB validation test, the temperature homogeneity was observed around 1 K using 20 PT100 sensors and modified COTS infrared camera. The emissivity value was 0.975 at $40^{\circ}C$ under atmospheric pressure.

EVALUATION OF FAR-INFRARED BIB-TYPE GE DETECTORS FABRICATED WITH THE SURFACE-ACTIVATED WAFER BONDING TECHNOLOGY

  • Hanaoka, Misaki;Kaneda, Hidehiro;Oyabu, Shinki;Hattori, Yasuki;Tanaka, Kotomi;Ukai, Sota;Shichi, Kazuyuki;Wada, Takehiko;Suzuki, Toyoaki;Watanabe, Kentaroh;Nagase, Koichi;Baba, Shunsuke;Kochi, Chihiro
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.351-353
    • /
    • 2017
  • To realize large-format compact array detectors covering a wide far-infrared wavelength range up to 200 µm, we have been developing Blocked-Impurity-Band (BIB) type Ge detectors with the room-temperature surface-activated wafer bonding technology provided by Mitsubishi Heavy Industries. We fabricated various types of $p^+-i$ junction devices which possessed a BIB-type structure, and evaluated their spectral response curves using a Fourier transform spectrometer. From the Hall effect measurement, we also obtained the physical characteristics of the $p^+$ layers which constituted the $p^+-i$ junction devices. The overall result of our measurement shows that the $p^+-i$ junction devices have a promising applicability as a new far-infrared detector to cover a wavelength range of $100-200{\mu}m$.

A STUDY OF THERMAL ANALYSIS OF KAONICS (적외선 카메라 KAONICS의 열해석)

  • Kang, Ji-Na;Lee, Sung-Ho;Jin, Ho;Park, Soo-Jong;Moon, Bong-Kon;Kim, Sang-Ho;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.467-480
    • /
    • 2004
  • It is very important to eliminate thermal background radiation for the near infrared camera system such as KAONICS (KAO Near Infrared Camera System). Thermal background radiations which come from window and cryostat wall influence IR detector and decrease IR system performance. Therefore the cold box which contains optics and detector housing must be cooled down to eliminate thermal background radiation. We carried out quantitative analysis to determine internal cooling temperature to reduce thermal noise in the J, H, Ks, and L bandpass. Additionally, we estimated the incoming heat load and then chose the cryocooler adequate to KAONICS's requirements. The cooling time and the final cooling temperature of the cold box were calculated. These results were also implemented to the system design.

PRELIMINARY OPTICAL DESIGN OF MIRIS, MAIN PAYLOAD OF STSAT-3 (과학기술위성3호 주탑재체 MIRIS의 광학계 시험설계)

  • Yuk, I.S.;Jin, H.;Lee, S.;Park, Y.S.;Lee, D.H.;Nam, U.W.;Park, J.H.;Han, W.Y.;Lee, J.W.
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.201-209
    • /
    • 2007
  • We have preliminarily designed two infrared optical systems of the multi-purpose infrared camera system (MIRIS) which is the main payload of STSAT-3. Each optical system consists of a Cassegrain telescope, a field lens and a 1:1 re-imaging lens system that is essential for providing a cold stop. The Cassegrain telescope is identical for both of two infrared cameras, but the field correction lens and re-imaging lens system are different from each other because of different bands of wavelength. The effective aperture size is 100mm in diameter and the focal ratio is f/5. The total length of the optical system is 300mm and the position of the cold stop is 25mm from the detector focal plane. The RMS spot size is smaller than $40{\mu}m$ over the whole detector plane.