• Title/Summary/Keyword: infrared detector

Search Result 321, Processing Time 0.024 seconds

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

Design and Implementation of Concentration Calculation Algorithm for the Infrared Combustible Gas Detector (적외선 가연성 가스검지기의 농도 산출 알고리즘의 설계 및 구현)

  • Han, Seungho;Lyu, Geunjun;Lee, Yeonjae;Kim, Hiesik;Park, Gyoutae
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.145-152
    • /
    • 2016
  • Recently, we can find news about toxic and combustible gas accident. So, we have to develop gas detector that can measure gas at dangerous area for preventing gas accidents. In this paper, we calculate a approximation function from sensor's output using the linear regressiong. And we develop software algorithm using Neville's algorithm for measuring gas concentration. Finally, we compare our algorithm with combustible gas detectors that are already developed, by using standard gas samples manufactured Korea Gas Safety. As a result of this experiment, we confirm that performance of our algorithm is more improved than performance of already developed combustible gas detectors. In the future, we'll research how to improve reliability from using count, temperature and humidity. And we'll design hardware applied explosion proof for safety.

Design of readout circuit for linear two-color infrared detector array (선형 종ㆍ원적외선 이중대역 동시 검출기배열을 위한 신호취득회로의 설계)

  • 김철범;우두형;강상구;이희철
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.49-56
    • /
    • 2004
  • A new readout circuit(ROIC) for linear HgCdTe 64${\times}$2 two-color Infrared (IR) detector is described. This circuit is based on the buffered direct injection(BDI) technology with high injection efficiency. By using saturation current isolation circuit, the proposed ROIC removed the problems that LWIR(Long Wavelength InfraRed) signal distort when MWIR(Middle Wavelength InfraRed) signal saturates so that new ROIC has larger measurable temperature range about 120k than that of previous circuit and it is also tolerant for dead pixel in MWIR detector. The designed circuit was fabricated using 0.6um 2-poly 3-metal CMOS process. We measured that the designed circuit outputs MWIR signal and LWIR signal simultaneously and saturation current isolationcircuit also operates well. Next, measured noise was about 53uV at room temperature and it can be assumed that designed circuit can satisfy nearly 95% BLIP condition at 77K.

Development of A Multi-sensor Fusion-based Traffic Information Acquisition System with Robust to Environmental Changes using Mono Camera, Radar and Infrared Range Finder (환경변화에 강인한 단안카메라 레이더 적외선거리계 센서 융합 기반 교통정보 수집 시스템 개발)

  • Byun, Ki-hoon;Kim, Se-jin;Kwon, Jang-woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.2
    • /
    • pp.36-54
    • /
    • 2017
  • The purpose of this paper is to develop a multi-sensor fusion-based traffic information acquisition system with robust to environmental changes. it combines the characteristics of each sensor and is more robust to the environmental changes than the video detector. Moreover, it is not affected by the time of day and night, and has less maintenance cost than the inductive-loop traffic detector. This is accomplished by synthesizing object tracking informations based on a radar, vehicle classification informations based on a video detector and reliable object detections of a infrared range finder. To prove the effectiveness of the proposed system, I conducted experiments for 6 hours over 5 days of the daytime and early evening on the pedestrian - accessible road. According to the experimental results, it has 88.7% classification accuracy and 95.5% vehicle detection rate. If the parameters of this system is optimized to adapt to the experimental environment changes, it is expected that it will contribute to the advancement of ITS.

Uncooled Pyroelectric Thin-film $(Ba,Sr)TiO_3$ Infrared Detector Thermally Isolated by Dielectric Membrane (유전체 멤브레인에 의해 열차단된 비냉각 초전형 박막 $(Ba,Sr)TiO_3$적외선 검지기)

  • Go, Seong-Yong;Jang, Cheol-Yeong;Kim, Dong-Jeon;Kim, Jin-Seop;Lee, Jae-Sin;Lee, Jeong-Hui;Han, Seok-Yong;Lee, Yong-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2001
  • Uncooled pyroelectric thin-film (Ba,Sr)TiO$_3$ infrared detectors thermally isolated from Si-substrate by Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-membrane have been fabricated, and figures of merit for detectors were examined. The detector at $25^{\circ}C$ in air showed relatively high voltage responsivity of about 168.8 V/W and low specific detectivity of about 2.6$\times$10$^4$cm.Hz$^{1}$2//W at 1 Hz-chopping frequency because of very small signal-to-noise voltage ratio. It could be found that both thermal noise voltage and thermal time constant of the detector were very large by analyzing dependences of output waveforms on chopping frequency and temperature.

  • PDF

Detection Based - Adaptive Windowed Nonlinear Filters for Removal of One-Side Impulse Noise in Infrared Image (적외선 영상의 단측형 충격잡음 제거를 위한 검출기반 적응윈도우 비선형 필터)

  • LEE JE-IL
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.83-88
    • /
    • 2005
  • In this paper, detection based - adaptive windowed nonlinear filters(DB-AWNF) are proposed for removing one-side impulse noise in infrared image. They are composed of impulse detector and window-size-variable median filters. Impulse detector checks whether current pixel is impulse or not using range function and nonlinear location estimator. If impulse is detected, current pixel is filtered according to four kinds of local masks by use of median filter. If not. current pixel is delivered to output like identity filter. In qualitative view, the proposed could have removed heavy corrupted noise up to $20\%$ and reserved the details of image. In quantitative view, PSNR was measured. The proposed could have 13 - 31[dB] more improved performance than those of median($3{\times}3$) filter and 18 - 25[dB] more improved performance than those of median($5{\times}5$) filter.

Design of Imaging Optical System with 24mm Focal length for MWIR (MWIR용 24mm 초점거리를 가지는 결상광학계의 설계)

  • Lee, Sang-Kil;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.203-207
    • /
    • 2018
  • This paper deals with the design and development of a lens system capable of imaging an infrared image of $3{\sim}5{\mu}m$ wavelength bands with a focal length of 24mm and good atmospheric transmission characteristics. The design used CodeV, a commercial design program, and the optimization is carried out with weighting to eliminate chromatic aberration, spherical aberration and distortion. The designed lens system consists of two lenses consisting of Si and Ge. Each lens has an aspherical surface on one side. And this optical system has the resolution of the characteristics that the MTF value is 0.40 at the line width of 29lp/mm and the MTF value is 0.25 at the line width of 20lp/mm. This optical system is considered to have the capability to be applied to the thermal imaging camera for MWIR using the $206{\times}156$ array infrared detector of $25{\mu}m$ pixels and the $320{\times}240$ array infrared detector of $17{\mu}m$ pixels.

Electrical Properties of Co- and Cu-Doped Nickel Manganite System Thick Films for Infrared Detectors

  • Lee, Dong-Jin;Lee, Sung-Gap;Kim, Kyeong-Min;Kwon, Min-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.261-264
    • /
    • 2017
  • $Ni_{0.79}Co_{0.15-x}Cu_xMn_{2.06}O_4$ ($0{\leq}x{\leq}0.09$) thick films were fabricated using the conventional solid-state reaction method and screen-printing method. Structural and electrical properties of specimens based on the amount of Cu were observed in order to investigate their applicability in the infrared detector. All specimens showed a single spinel phase with a homogeneous cubic structure. As the amount of Cu increased, the average grain size increased and was found to be approximately $5.01{\mu}m$ for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen. The thickness of all specimens was approximately $55{\sim}56{\mu}m$. As Cu content increased, the resistivity and TCR properties at room temperature decreased, and these values for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen were $502{\Omega}-cm$ and $-3.32%/^{\circ}C$, respectively. The responsivity and noise properties decreased with an increase in Cu content, with the specimen with a Cu content of x=0.09 showing 0.0183 V/W and $5.21{\times}10^{-5}V$, respectively.

Development of Standing and Moving Human Body Sensing Module Using a Chopper of Shutter Method (셔터방식의 쵸퍼를 이용한 정지 및 이동인체 감지 모듈 개발)

  • Cha, Hyeong-Woo;Lee, Won-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.109-116
    • /
    • 2016
  • Sensing module of standing and moving human body using shutter method was developed. The module consists of Fresnel lens, pyroelectric infrared (PIR) sensor, interface circuit of the PIR, micro control unit(MCU), and alarm light emitting diode(LED). The principle for standing human body is chopping the thermal of human body using camera shutter. The human sensing signal in MCU by algorithm of interrupt function is detected. By unifying an apparatus and print circuit board(PCB), the developed module can be replaced as commercial moving human body detector. Experiment results show that sensing distance is about 7.0m and sensing angles is about $110^{\circ}$ at room temperature. In these condition, sending ratio was 100% and the power dissipation of the module was 100mW.