• Title/Summary/Keyword: influence detection measure

Search Result 29, Processing Time 0.03 seconds

Detection of Aesthetic Measure from Stabilized Image and Video (정지영상과 동영상에서 미도의 추출)

  • Rhee, Yang-Won;Choi, Byeong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.11
    • /
    • pp.33-38
    • /
    • 2012
  • An free-fall object is received only force of gravity. Movement that only accept gravity is free-fall movement, and a free-falling object is free falling body. In other words, free falling body is only freely falling objects under the influence of gravity, regardless of the initial state of objects movement. In this paper, we assume, ignoring the resistance of the air, and the free-fall acceleration by the height does not change within the range of the short distance in the vertical direction. Under these assumptions, we can know about time and maximum height to reach the peak point from jumping vertically upward direction, time and speed of the car return to the starting position, and time and speed when the car fall to the ground. It can be measured by jumping degree and risk of accident from car or motorcycle in telematics.

Implementation and estimation of the urophonography measurement system for diagnosis of Lower urinary tract symptom (하부요로계 폐색 진단용 요류음 계측 시스템의 구현 및 평가)

  • Jeong, Do-Un;Cho, Seong-Taek;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.7-15
    • /
    • 2005
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282$ Hz of the urophonography signal.

Design of Filter for Output Signals in Incremental Encoder for Detecting Speed and Position of Motors (전동기 속도 및 위치검출용 증분형 엔코더 출력신호 필터 설계)

  • Ahn Jung-Ryol;Lee Hong-Hee;Kim Heung-Gun;Nho Eui-Cheol;Chun Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.290-295
    • /
    • 2005
  • The incremental encoder has been mostly used to measure the speed and position of the motor. As the output signals of encoder are high frequency digital signals, they have much influence on radiation noises due to switching of the power semiconductor circuits. It is so difficult to suppress the noises with the conventional LPF. In this paper, the hardware digital filter for suppressing noises in the output signals of the encoder signals is developed. As both the clock frequency and counter in the digital filter for encoder are easily adjusted according to the kinds of noises, any noises in the encoder can be entirely eliminated. The performance of the digital filter has been verified by simulation and experimental results.

Analysis of Cylinder Compression Pressure & Valve Timing by Motoring Current & Crank Signal during Cranking (모터링시 전류 파형과 크랭크각 센서를 이용한 기관의 압축압력 및 밸브 타이밍 분석)

  • Kim, In-Tae;Park, Kyoung-Suk;Shim, Beom-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.45-50
    • /
    • 2011
  • Compression pressure of individual cylinder and valve timing have big influence on combustion pressure, indicated mean effective pressure (IMEP), emission, vibration, combustion noise and many other combustion parameters. Conventional method, however, to check compression pressure uniformity is done by mechanical pressure gage and valve timing is checked manually. This conventional method causes inaccuracy of cylinder pressure measurement because of different cranking speed results from battery status and temperature. Also to check valve timing, related FEAD parts should be disassembled and timing mark should be checked. This study describes and suggests new methodology to measure compression pressure by analysis of start motor current and to check valve timing by cylinder pressure with high accuracy. Results, it is found that detection of bulky as well as small leaky cylinder is possible by cranking motor current analysis and wrong valve timing can be detected by cylinder pressure analysis and cam and crank sensor signal.

Implementation of the BPH Diagnosis System for Home Health Care Using FPGA (FPGA를 이용한 홈 헬스케어용 전립선 비대증 진단시스템 구현)

  • Jeong, Do-Un;Chung, Wan-Young;Kim, Jeong-Kuk
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2006.06a
    • /
    • pp.97-100
    • /
    • 2006
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the BPH(benign prostatic hypertrophy). The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluates the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282Hz$ of the urophonography signal.

  • PDF

A Study of the Couplant Effects on Contact Ultrasonic Testing

  • Kim, Young-H.;Song, Sung-Jin;Lee, Sung-Sik;Lee, Jeong-Ki;Hong, Soon-Shin;Eom, Heung-Seop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.621-626
    • /
    • 2002
  • The amplitude of a back-wall echo depends on the reflection coefficient of the interface between a transducer and a test material when using contact pulse-echo ultrasonic testing. A couplant is used to transmit ultrasonic energy across the interface, but has an influence on the amplitude of the pulse-echo signal. To investigate the couplant effect on pulse-echo ultrasonic testing, back-wall echoes are measured by using various couplants made of water and glycerine in a carbon and austenitic stainless steel specimens. The amplitude of the first back-wall echo and the apparent attenuation coefficient increases with the acoustic impedance of the couplant. The couplant having a higher value of the transmission coefficient is more effective for flaw detection. The reflection coefficient should be known in order to measure the attenuation coefficient of the test material.

The Influence of Topic Exploration and Topic Relevance On Amplitudes of Endogenous ERP Components in Real-Time Video Watching (실시간 동영상 시청시 주제탐색조건과 주제관련성이 내재적 유발전위 활성에 미치는 영향)

  • Kim, Yong Ho;Kim, Hyun Hee
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.8
    • /
    • pp.874-886
    • /
    • 2019
  • To delve into the semantic gap problem of the automatic video summarization, we focused on an endogenous ERP responses at around 400ms and 600ms after the on-set of audio-visual stimulus. Our experiment included two factors: the topic exploration of experimental conditions (Topic Given vs. Topic Exploring) as a between-subject factor and the topic relevance of the shots (Topic-Relevant vs. Topic-Irrelevant) as a within-subject factor. For the Topic Given condition of 22 subjects, 6 short historical documentaries were shown with their video titles and written summaries, while in the Topic Exploring condition of 25 subjects, they were asked instead to explore topics of the same videos with no given information. EEG data were gathered while they were watching videos in real time. It was hypothesized that the cognitive activities to explore topics of videos while watching individual shots increase the amplitude of endogenous ERP at around 600 ms after the onset of topic relevant shots. The amplitude of endogenous ERP at around 400ms after the onset of topic-irrelevant shots was hypothesized to be lower in the Topic Given condition than that in the Topic Exploring condition. The repeated measure MANOVA test revealed that two hypotheses were acceptable.

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Hapten Synthesis and Influence of Coating Ligands on Enzyme-linked Immunoreaction of DDT

  • Hong, Ji- Youn;Kim, Jong-Hyun;Choi, Myung-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1413-1431
    • /
    • 2002
  • For the development of immunodetection method of 4,4'-dichlorodipheny-2,2,2-trichloroethane (p,p'-DDT), a persistent and broad toxic organochlorine insecticide, various DDT derivatives were synthesized and characterized for the use of immunogens and the coating ligands for the antibody evaluation. The appropriate lengths of linkers were introduced to investigate more efficient DDT derivatives. Among these hapten derivatives, 2,2-Bis(4-chlorophenyl)acetic acid (DDA), 5,5-Bis(4-chlorophenyl)-5-hydroxypentanoic acid (DDHP) and 5,5-Bis(4-chlorophenyl)-5-chloropentanoic acid (DDCP) were conjugated with keyhole limpet hemocyanin (KLH) for the use of immunogen to produce antibodies. 6,6-Bis(4-chlorophenyl)-6-hydroxyhexanoic acid (DDHH) and 3-[6,6-Bis(4-chlorophenyl)-6-hydroxyhexanoylamino]propanoic acid (DDHHAP) in addition to above hapten derivatives were conjugated to ovualbumin (OVA) and bovine serum albumin (BSA) for the use of coating ligands to measure the titration level of antibody and the displacement of free analytes. Three matching pairs of antibodies and coating ligands were selected for the simultaneous detection of p,p'-DDT and its related compounds of DDA and 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene (p,p'-DDE) by investingating the displacement of free analytes in an indirect ELISA. These were PAb #1 and coating ligand DDCP-OVA, PAb #1 and DDHHAP-OVA, and PAb #3 and DDHHAP-OVA. The most useful immunoreaction for DDT analytes were obtained using PAb #3 and coating ligand DDHHAP-OVA showing 3.4 ng/mL of lower limit of detection. These results indicated that titration level and free analytes displacement were greatly influenced by hapten derivatized and carrier proteins conjugated.