• Title/Summary/Keyword: industrial sewage sludge

Search Result 116, Processing Time 0.031 seconds

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

Effects of Municipal Sewage and Industrial Wastewater Sludge Composts on Chemical Properties of Soil and Growth of Corn Plant (폐하수슬러지 퇴비 시용이 토양의 화학성 및 옥수수의 생육에 미치는 영향)

  • Lee, Hong-Jae;Cho, Ju-Sik;Lee, Won-Kyu;Heo, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.220-226
    • /
    • 1997
  • To study the possibility of agricultural utilization of the municipal sewage and the industrial wastewater sludges, the chemical properties of soil, the growth response of corn plant and uptake of inorganic nutrients in plant tissues were investigated by application of the composts made of the sludges to the pots at the rate of 2,000kg/10a. The contents of organic matter, T-N, $P_2O_5$ and K in soil were increased by application of the composts. Each heavy metals contents in soil were increased very slightly by application of the composts. The fresh weights of corn plant were increased with $9{\sim}19%\;and\;60{\sim}79%$ at the plot of compost and NPK+composts in comparing with the plot of NPK, respectively. Uptake of N, $P_2O_5,\;K_2O$, CaO and MgO in stem and leaf of corn plant were increased by applications of the composts.

  • PDF

The Assesment of Heavy metal Pollution in Sewage Sludeges from Gully Pots Alongside Some Main Roads in Seoul, Korea (서울시 도로변의 빗물받이에서 체취한 하수슬러지의 중금속 오염 평가)

  • 이평구
    • Economic and Environmental Geology
    • /
    • v.32 no.6
    • /
    • pp.633-644
    • /
    • 1999
  • Gully pot is a part of urban darainage system to butter the runoff water fluxes from road to rivers and to minimize environmental pollution by prevending over the surrounding area. A series of studies have been carried out concerning the physicochemical characteristics of the sewage sludge sediments sttling down in such a gully pot in order to over to evaluate the contamination for heavy metals such as pb, Zn, Cu and Cd. The roadside soil and sewage sludge samples from gully pots were characterized by XRD analyses and sequential extraction : Zn 2595.7$\mu$g/g; Cd9.8$\mu$/g; Cu602.5$\mu$g/g; Pb260.0$\mu$g/g),because of a long-term accumulation of vehicle- and industrial-related pollutants. Mean Zn concentration in Yeouido (3873$\mu$g/g) and Junggu(3262$\mu$g/g)areas are 4-5 times higher than those in Dobonggu area, suggesting that Zn may be derived from automobile traffic (including the rubber of automobile tires). The mean concentrations of Cu and Cr are very significantly high in Junggu and Gurogu areas, possibly due to the industrial activities in these areas. The low Pb levels throughtotut the whole study areas in Seoul can be accounted for the use of unleaded gasoline since 1987. Sequential extraction experiments illustrate that a major part of Zn is bound to FII and FIII, representing about 88% of the total Zn concentration. Fraction IV, related to orgnic matter, is mostly significant for Cu accounting for 60% of the total Cu, and FII is next in importance. The main carriers of Pb are the fractions III, II and FIV, and in that order. The behavior of Cd is quite different from other elements (Zn, Cu, Pb), and most of the Cd is associated with FV. Changes in the physicochemical environments (such as acidification) may result in severe environmental pollution of surface water and rivers with respect to heavy metals (especially Zn and Cu).

  • PDF

Production of Compost Using Organic wastes

  • Lee, Jang-Hoon;Jung, Joon-Oh;Kwon, Hyuk-Ku;Nam, Youn-Ku;Yun, Jung-Won
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.406-409
    • /
    • 2005
  • Since 2003, Korean government has restricted landfill application of organic waste, which shares approximately 56% of total waste sludge from municipal and industrial wastewater treatment plants. In addition, enforcement of the ocean disposal prohibition law is effective from 2005. Organic sludge was composted for the purpose of converting to organic fertilizer. After moisture content was regulated with bulking agents aerobic treatment performed. When composting was conducted, commercial and activated microbe materials, identified from soil were seeded in sewage sludge. Carbon dioxide production was increased sharply after 24 hours. Temperature and pH of compost reached to $66.2^{\circ}C$ and 8. Heavy metals were lower than their regulatory limits, which enable it to utilize as organic fertilizer.

  • PDF

Effect of trace oxygen on H2S removal in anaerobic digestion (혐기소화 시 미량 산소가 H2S 제거에 미치는 영향)

  • Jo, Eun-Young;Park, Kwang-Su;Ahn, Johng-Hwa
    • Journal of Industrial Technology
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2019
  • This work experimentally determined the effect of microaerobic condition on anaerobic digestion of thickened waste activated sludge in semi-continuous mesophilic digesters at hydraulic retention time of 20 days. The concentration of hydrogen sulfide was $7{\pm}2ppm$ at the microaerobic condition and $14{\pm}2ppm$ at the anaerobic condition. Removal efficiency of volatile solid was not significantly different between microaerobic ($40{\pm}8%$) and anaerobic ($38{\pm}8%$) conditions. There was no important difference between microaerobic ($1,352{\pm}98ml/d$) and anaerobic ($1,362{\pm}104ml/d$) conditions in the biogas production, either. Therefore, it could be concluded that the application of the microaerobic condition was an efficient method of the hydrogen sulfide removal from the biogas.

Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed (기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교)

  • Lee, Youngjae;Kim, Jongmin;Kim, Donghee;Lee, Yongwoon
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.80-89
    • /
    • 2017
  • The bubbling fluidized bed (BFB) reactor with a diameter of 0.1 m and a height of 1.2 m was used for experimental study of co-firing and emission characteristics fueled by sewage sludge (SS) and wood pellet (WP). The facility consists of a fluidized bed reactor, feeding system, cyclone, condenser and gas analyzer, The mean particle diameter and minimum fluidization velocity are $460{\mu}m$ and $0.21ms^{-1}$ respectively. SS produced from Korea and WP from Canada were examined. The various mixing ratios of WP were 20, 50, and 80% based on HHV. The equivalence ratio of 1.65, reactor temperature of $800^{\circ}C$, air flow rate of $100Lmin^{-1}$, and fluidization number of 4 were fixed in the BFB experiment. In TGA, the range of combustion temperature of SS was wider than that of WP. It represents that the combustibility of WP is higher than that of SS. The BFB reactor temperature was maintained between 800 and $900^{\circ}C$. CO emission of SS was high because of lower combustibility. $NO_X$ and $SO_X$ formation of SS were higher than that of WP since high nitrogen and sulfur contents of SS. CO, $NO_X$, and $SO_X$ formation were suppressed as the mixing ratio of WP was increased. The slagging and fouling tendencies show high in all test conditions.

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye;LEE, So-Hee;YUN, Yeo-Jin;CHOI, Soo-Young;JUNG, Min-Jae;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

A study on Establishment of Vermicomposting Index Using Leakage Water (침출액을 이용한 지렁이 퇴비화지표 설정에 관한 연구)

  • Lee, Chang-Ho;Kim, Jong-Oh;Choi, Suk Soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.1
    • /
    • pp.178-184
    • /
    • 2007
  • In the present work, the vermicomposting index was investigated using leakage water from sludge to develop the process of mechanization and automation in the earthworm-cast treatment. The in situ sewage sludge was used batch and continuous experiments. Due to different treatment processes, the physico-chemical characteristics of liquid extracted from sludge was the similar change pattern. However, some items, such as Oxidation Reduction Potential (ORP), pH, Electrical Conductivity (EC) and $NH_3-N$, showed the distinct changes between pre- and post-vermicomposting. Also, The ORP and EC were the best parameters for the vermicomposting index. These results offered that the present vermicomposting technology was an actual earthworm-cast treatment.

  • PDF

Isolation and Culture Conditions of Hydrogen-producing Bacterium from Sewage Sludge (하수슬러지에서 수소생산 균주의 분리 및 배양조건)

  • Woo, Dae-Sik;Joo, Hyun;Lee, Jae-Hwa
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.407-411
    • /
    • 2013
  • Hydrogen producing bacterium, strain AS12 was isolated from the sludge of the anaerobic wastewater treatment process of south sewage treatment plant, Busan city. Phylogenetic analysis based on 16S rRNA sequence studies indicated that AS12 belonged to the genus Escherichia coli sp.. The optimum temperature and pH for hydrogen production were $35^{\circ}C$ and 8.0, respectively. The impact of the types and concentrations of carbon and nitrogen sources in the media on hydrogen production was investigated. The optimum carbon and nitrogen concentrations were 10 g/L of galactose and 5 g/L of peptone, respectively.

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.