Browse > Article
http://dx.doi.org/10.4491/KSEE.2012.34.4.223

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge  

Na, En-Soo (Shin Woo Industrial Development Co., Ltd.)
Shin, Sung-Soo (Shin Woo Industrial Development Co., Ltd.)
Shin, Mi-Soo (Department of Environmental Engineering, Chungnam National University)
Jang, Dong-Soon (Department of Environmental Engineering, Chungnam National University)
Publication Information
Abstract
The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.
Keywords
Sewage Sludge; Multiple Screw Type Dryer; Numerical Study; Drying Efficiency;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pack, J. H, Lee, M. S. and Choi, H. I., "The optimum design of treatment facilities for dehydrated sewage sludge by plasma pyrolysis, casification, vitrification process," Proceeding of the Korean Pyrolysis & Melting Conference(2002).
2 Veslind, P.A., Worrell, and W., Reinhart, D., "Processing of municipal soild waste," Solid waste engineering, BROOKS/COLE, Pacific grove, 180-181(2002).
3 Mulet, A., Berna, A., Borras, M. and Pinaga, F., "Effect of air flow rate on carrot drying," Drying Technol., 5(2), 245-258(1987).   DOI   ScienceOn
4 Patankar, S. V., Numerical heat transfer and fluid flow, McGraw-Hill Company(1980).
5 Launder, B.E. and Spalding, D.B., "Mathematical modeling of turbulence," Academic press, New York(1972).
6 Magnussen, B. F. and Hjertager, B. H., "On mathematical modeling of turbulence combustion with special emphasis on soot formation and combustion," sixteenth symposium on combustion institute, Pittsburgh, 719-729(1977).
7 Hwang, J. W., Phae, C. G., Ko, H. B. and Ko, B. S., "Investigation on heat efficiency of incineration system combined with dryer for treatment of sewage and wastewater sludge," Kor. Soc. Waste Manage., 19(2), 175-182(2002).