• 제목/요약/키워드: inductively coupled plasma-mass spectrometry

검색결과 237건 처리시간 0.026초

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권4호
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry에 의한 $U_3Si/Al$ 사용후핵연료 중 La의 분리 및 정량 (Determination of La in $U_3Si/Al$ Spent Nuclear Fuel by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry)

  • 한선호;최광순;김정석;전영신;박양순;지광용;김원호
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.601-607
    • /
    • 2000
  • 란탄은 사용후핵연료의 연소도 지표원소들 중 하나로써 이용되고 있다. $U_3Si/Al$ 사용후핵연료는 다량의 U과 Al 속에 미량의 La이 포함되어 있어 정량시 매질의 영향을 줄이기 위해 화학적 분리가 요구된다. La의 분리 및 측정을 위해 IC-ICP-MS를 이용하였으며, 우선 방사성 시료를 취급하기 위하여 유도결합 플라스마 질량분석기의 플라스마 부분 및 분리관을 방사선 차폐 글로브박스 내에 설치하였다. CG10 분리관과 ${\alpha}$-HiBA 용리액을 사용하여 U, Al, La 및 몇 가지 핵분열생성물 (Sr, Zr, Y, Mo, Ru, Pd, Rh, Cs, Ba, Ce, Pr, Nd, Sm, Eu 및 Cd)의 머무름 거동을 살펴보았다. 0.2 M ${\alpha}$-HiBA 용리액에서 U과 Al이 초기에 용출되므로 분리관과 ICP-MS의 시료분무기 사이에 3방향 밸브를 연결하여 다량의 U과 Al이 ICP-MS로 유입되지 않도록 하므로써 매질의 영향을 줄일 수 있었다. 이 조건에서 La은 약 12분 정도에 분리 및 측정이 가능하였으며, $1-10{\mu}g/L$ (ppb)의 농도범위가 측청에 적합하였고 시료양을 $200{\mu}L$ 취할 경우 La의 검출한계는 $0.25{\mu}g/L$이었다.

  • PDF

ICP-MS에 의한 지하수 중의 Germanium 분석에 관한 연구 (Determination of Germanium in Spring Waters by Inductively Coupled Plasma Mass Spectrometry)

  • 박경수;송승연;심의섭;김선태
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.120-124
    • /
    • 1998
  • 지하수 중의 극미량 germanium을 ICP-MS로 신속, 정확하게 분석할 수 있었으며 질량수 74를 분석하는 것이 가장 방해영향이 적음을 알 수 있었다. 지하수 중의 약 30%만이 $0.1{\mu}g/L$ 이상의 germanium을 함유하였고, 유기 germanium을 포함하는 지하수의 존재도 확인하였다.

  • PDF

골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교 (Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead)

  • 윤충식;최인자;박성균;김록호
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.152-158
    • /
    • 2003
  • 본 연구는 인체의 골중 납 농도를 측정하는데 필요한 시료 전처리법과 기기 분석법을 평가하기 위하여 수행되었다. 절단한 인간 사체 다리의 뼈를 상온에서의 산 분해법과 마이크로웨이브 분해법 (microwave oven method)을이용하여 납을 추출하였으며, 유도결합 플라즈마 질량분석법 (ICP-MS)과 흑연로 원자 흡수 분광 광도법 (GF-AAS)으로 납 농도를 측정하였다. 표준시료를 이용하여 회수율을 조사한 결과, 산분해 후 ICP-MS로 측정한 경우 높은 회수율을 보였으나, 산분해 후 GF-AAS로 측정한 것은 표준 농도보다 낮은 값을 보였으며, 마이크로웨이브 분해한 경우는 두 측정기기 모두 표준 농도보다 높은 값을 보였다. 뼈 시료의 경우, 산분해 후 ICP-MS로 측정한 납 농도는 GF-AAS의 값과 높은 상관성을 보였으나 (상관계수 = 0.983), GF-AAS가 ICP-MS보다 계통적으로 높은 값을 측정하였다. 마이크로웨이브 분해 역시 두 분석방법이 높은 상관성을 보였으나 (상관계수 = 0.950), 대체로 산분해에 의한 값보다 높은 농도를 보였다. 결론적으로, 상온에서 질산으로 분해 후 ICP-MS를 이용하여 측정한 것이 골중 납 농도를 결정하는데 편이성과 정확성 면에서 가장 효율적인 방법으로 보인다.

ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구 (Analysis of Copper, Zinc in Serum Using ICP-MS & AAS)

  • 이예진;김동엽;이고은;조영숙
    • 대한임상검사과학회지
    • /
    • 제41권1호
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

Synthesis of Silver Nanoparticles from the Decomposition of Silver(I) [bis(alkylthio)methylene]malonate Complexes

  • Lee, Euy-Jin;Piao, Longhai;Kim, Jin-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.60-64
    • /
    • 2012
  • Silver(I) [bis(alkylthio)methylene]malonates were synthesized from the reaction of silver nitrate and potassium [bis(alkylthio)methylene]malonates. The structures of the Ag complexes were characterized with nuclear magnetic resonance (NMR), inductively coupled plasma atomic emission spectrometry (ICP-AES) and elemental analysis. Ag nanoparticles (NPs) were obtained from the decomposition of the Ag complexes in 1,2-dichlorobenzene at $110^{\circ}C$ without an additional surfactant. The average sizes of the Ag NPs are in the range of 5.1-6.3 nm and could be controlled by varying the length of the alkyl chain. The optical properties, crystalline structure and surface composition of Ag NPs were characterized with ultraviolet-visible (UV-visible) spectroscopy, transmission electron microscopy (TEM), X-ray diffraction (XRD), gas chromatography-mass spectrometry (GC-MS), X-ray Photoelectron Spectroscopy (XPS) and thermal gravimetric analysis (TGA).

대기 분진의 무기 화학적 조성 분석과 Chemical Mass Balance에 의한 오염원 기여도 산출 (Characterization of Inorganic Chemicals in Total Suspended Particulates and a Source Apportionment by Chemical Mass Balance Model)

  • 서영화;구자공
    • 한국대기환경학회지
    • /
    • 제8권2호
    • /
    • pp.112-120
    • /
    • 1992
  • Twenty four metal, nonmetal elements and 4 major anions in total suspended particulates (TSP) collected at two sites in Daejon city from october to december in 1991 by a Hi-vol sampler were thoroughly analyzed by Inductively Coupled Plasma/ Atomic Emission Spectrometry (ICP/AES) and Ion Chromatography (IC). These analyzed data were used to perform a receptor modeling using the Chemical Mass Balance (CMB) for the source apportionment of TSP sample. Approximately 60% TSP weight in industrial complex area was influenced by potential industrial sources and 25% was by heating fuels and automobile emissions, whereas a half of TSP in residential area was influenced by surrounding environment and more than 35% of TSP was influenced by heating fuels. The CMB model provided source apportionment results reasonably and scientifically with a minor limitation.

  • PDF

Lu-Hf 동위원소시스템의 지질학적 활용 (Lu-Hf Isotopic Systematics and Its Applications for Geology)

  • 최성희
    • 암석학회지
    • /
    • 제23권3호
    • /
    • pp.229-237
    • /
    • 2014
  • Lu-Hf 시스템은 다중검출기부착 유도결합플라즈마 질량분석기의 발달과 함께 최근 들어 지질학에 폭넓게 활용되고 있는 동위원소시스템이다. 본 연구는 Lu-Hf 동위원소시스템의 기본 원리를 소개하고, 지질연 대측정 도구로서 또 암석 성인 연구의 지시자로서의 Lu-Hf 시스템이 활용되고 있는 사례를 소개하며 향후 연구 방향을 제안한다. 나아가서는 우리나라 고철질 내지는 초고철질 암석시료에 활용한 사례를 바탕으로 Hf 동위원소를 통해 본 한반도 맨틀의 생성과 진화과정에 대해 논의한다.

수소화물 발생-유도결합플라스마 질량분석법에 의한 철강 중의 납의 정량 (Determination of Lead in Steels by Hydride generation-Inductively Coupled Plama/Mass Spectrometry)

  • 박창준;송선진;이동수
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.410-415
    • /
    • 2001
  • 철강 시료 중의 납 분석을 위하여 수소화물 발생법을 플라스마에 납을 선택적으로 주입하고 유도결합플라스마 질량분석법으로 측정하는 분석법을 개발하였다. 납 수소화물 $PbH_4$의 생성을 위해서는 $NaBH_4$와 반응 전에 먼저 준안정 상태의 Pb(IV)로 만들어주기 위하여 산화제가 필요하다. $1000{\mu}g/mL$ 이상의 철 매질을 함유하는 시료용액으로 납 수소화물을 발생시키기 위한 최적조건을 찾는 연구를 수행하였다. 철 매질이 $10{\mu}g/mL$ 이상 존재할 때는 $K_2Cr_2O_7$이 효과적인 산화제로 작용하였으며 젖산을 가하여 감도를 향상시켰다. 시료용액의 산농도 그리고 산화제와 젖산 농도의 최적값은 철 매질의 농도에 따라 달랐다. 동위원소 희석법을 사용하여 납을 정량하였으며 철강 표준물질 NIST SRM 361, 362 분석결과는 불확도 범위안에서 검정값과 잘 일치하였다.

  • PDF

Feasibility Study of Isotope Ratio Analysis of Individual Uranium-Plutonium Mixed Oxide Particles with SIMS and ICP-MS

  • Esaka, Fumitaka;Magara, Masaaki;Suzuki, Daisuke;Miyamoto, Yutaka;Lee, Chi-Gyu;Kimura, Takaumi
    • Mass Spectrometry Letters
    • /
    • 제2권4호
    • /
    • pp.80-83
    • /
    • 2011
  • Isotope ratio analysis of nuclear materials in individual particles is of great importance for nuclear safeguards. Although secondary ion mass spectrometry (SIMS) and thermal ionization mass spectrometry (TIMS) are utilized for the analysis of individual uranium particles, few studies were conducted for the analysis of individual uranium-plutonium mixed oxide particles. In this study, we applied SIMS and inductively coupled plasma mass spectrometry (ICP-MS) to the isotope ratio analysis of individual U-Pu mixed oxide particles. In the analysis of individual U-Pu particles prepared from mixed solution of uranium and plutonium standard reference materials, accurate $^{235}U/^{238}U$, $^{240}Pu/^{239}Pu$ and $^{242}Pu/^{239}Pu$ isotope ratios were obtained with both methods. However, accurate analysis of $^{241}Pu/^{239}Pu$ isotope ratio was impossible, due to the interference of the $^{241}Am$ peak to the $^{241}Pu$ peak. In addition, it was indicated that the interference of the $^{238}UH$ peak to the $^{239}Pu$ peak has a possibility to prevent accurate analysis of plutonium isotope ratios. These problems would be avoided by a combination of ICP-MS and chemical separation of uranium, plutonium and americium in individual U-Pu particles.