• 제목/요약/키워드: inductive reactance

검색결과 15건 처리시간 0.022초

초전도 전류 발전기의 유도리액턴스 손실에 관항 연구 (A Study on the Analysis of the Inductive Reactance Losses of a Superconducting Current Generator)

  • Ko, Tae-Kuk
    • 대한전기학회논문지
    • /
    • 제39권12호
    • /
    • pp.1317-1320
    • /
    • 1990
  • The inductive reactance losses of a superconducting current generator built at Case Western Reserve University has been analyzed. The calculations of the field in the spot make it possible to estimate the spot inductance as well as the filament inductance on the foil. It is shown that magnetic energy lost in switching the current is mainly due to the amplitude of the fluctuation in voltage associated with the inductive reactance losses of a superconducting current generator.

  • PDF

유도성 리액턴스 변화를 이용한 VCO의 설계 및 동작 연구 (A Design and Performance Investigation of VCO using Inductive Reactance Variation)

  • 오세환;서석태;구경완;이원희;허정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.405-408
    • /
    • 2000
  • We designed and fabricated VCO using inductive reactance variation at 2GHz. A varactor diode is one of the main devices in VCO, which varies capacitance depending on reverse voltage. In this paper, a varactor diode is not used as a variable capacitive reactance device but as an inductive device. The circuit design and simulation have been carried out using HP-MDS. The fabricated VCO is measured using the HP 8532B spectrum analyzer and the HP 4352B VCO/PLL analyzer. The experimental result shows the phase noise -110dBc/Hz at a 100kHz offset frequency, the control voltage sensitivity of 23MHz/V and a -3.5dBm output power with a D.C. current consumption of 5.9mA. The simulation and measurements show exact agreement except with regard to the oscillation frequency. The measured oscillation frequency is lower than the simulation result because there is some parasitic inductance in the PCB layout.

  • PDF

궤도 차량용 유도 급전/집전 장치의 특성평가 (The performance of inductive power collector used for railway vehicle system)

  • 한경희;이병송;백수현;권삼영;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.188-190
    • /
    • 2006
  • This paper suggests the inductive power collector using electromagnetic induction for railway vehicle such as the PRT(Personal Rapid Transit) system. Some ideas for inductive power collector design to improve the power transfer performance are presented. The inductive power of secondary part is related to mount of linked flux to secondary part by the length of air-gap, which is expected by such a system parameter as leakage reactance and magnetizing reactance. This paper will study for some performance of traditional transformer from equivalent circuit considering leakage reactance.

  • PDF

축소모델을 이용한 SSSC의 제어효과 및 계통응답 분석 (Analysis of Control Performance and Response of System using Scaled Model for SSSC)

  • 최종윤;홍순욱;장병훈;윤종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.202-204
    • /
    • 2000
  • This paper describes the theory and experimental result of scaled model of SSSC. The SSSC, a solid-state voltage source inverter coupled with a transformer, is connected in series with a transmission line. Injected voltage is almost in quadrature with the line current, thereby emulating an inductive or a capacitive reactance in series with the transmission line.

  • PDF

축소모델을 이용한 STATCOM의 제어효과 및 계통응답 분석 (Analysis of Control and Performance Response of System using Scaled Model for STATCOM)

  • 유현호;한영성;박상태;오관일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.199-201
    • /
    • 2000
  • This paper describes the theory and experimental result of scaled model of STATCOM. The STATCOM, a solid-state voltage source inverter coupled with a transformer, is tied to a transmission line. A STATCOM inject an almost sinusoidal current of variables magnitude, at the pont of connection. This injected current is almost in quadrature with the line voltage, thereby emulating an inductive or capacitive reactance at the point of connection with the transmission line.

  • PDF

대형접지전극시스템 접지임피던스의 측정 (Measurement of Grounding Impedances in Large-scale Grounding Electrode Systems)

  • 이경훈;최종혁;최영철;이규선;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.193-196
    • /
    • 2008
  • In these days, large structures are constructed and bonded with ground grid Because the distances between mesh and auxiliary electrodes are not enough in downtown areas, it is very difficult to measure the ground resistance of large scale grounding electrode systems. Actually the auxiliary electrodes for test are installed in grounding grid. This paper present the experimental results of ground resistance and impedance according to the location of auxiliary electrode. As a result, we get much lower resistances and impedances than real values the auxiliary electrodes are placed in the ground grid. In case that the auxiliary electrodes are located in the ground grid the resistances are very low and reactance only is inductive component.

  • PDF

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권2호
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선 (RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module)

  • 이동수
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.8-12
    • /
    • 2003
  • TO-can 레이저 다이오드를 사용한 광송수신기 모듈의 주파수 대역의 특성을 관찰하였다. 레이저 다이오드의 등가회로를 추출하기 위한 R-L-C변수는 임피던스 분석기를 이용하였다. 칩콘덴서를 사용하여 패키지내의 도선에 의한 인덕턴스 성분과의 임피던스 정합을 시도하였으나 저주파수 대역에서 공진으로 인한 경사가 발견되었다. 표면실장 형으로 소자를 구성하여 사용함으로써 공진주파수를 이동시켜 원하는 주파수 대역에서 공진 경사를 제거할 수 있었다.

나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기 (Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector)

  • 신임휴;김동욱
    • 한국전자파학회논문지
    • /
    • 제24권11호
    • /
    • pp.1104-1112
    • /
    • 2013
  • 본 논문에서는 감지기에서 특정 거리만큼 떨어진 곳에 버블 형태의 감지 영역을 형성하는 새로운 버블형 동작 감지기를 위해 나노초의 발진 기동 시간과 8.35 GHz의 중심주파수를 가지는 광대역 콜피츠 전압제어발진기를 설계 및 제작하였다. 전압제어발진기는 HEMT 소자 및 콜피츠 궤환 구조를 이용한 부성 저항부와 바랙터 다이오드 및 단락된 마이크로스트립 분기 선로를 이용한 공진부로 구성되었다. 패키지된 트랜지스터의 기생 인덕턴스로 인해 8.1 GHz에서 용량성 값에서 유도성 값으로 변하는 부성 저항부의 리액턴스 변화는 마이크로스트립 분기 선로와 직렬 캐패시터를 이용하여 보상하였다. 부성 저항 값을 결정하는 궤환 캐패시터들의 값을 조정함으로써 부성 저항 값 변화에 따른 발진 기동 시간 개선 여부와 부성 저항부의 입력 리액턴스 기울기 변화에 따른 대역폭 개선 여부도 조사되었다. 제작된 전압제어발진기는 2.3 GHz(28 %)의 튜닝 대역폭과 4.1~7.5 dBm의 출력 전력, 그리고 2 nsec 이하의 발진 기동 시간을 가지는 것으로 측정되었다.