• 제목/요약/키워드: indoor-impulse noise

검색결과 15건 처리시간 0.021초

공간크기에 따른 로켓모타 충격소음의 비교분석에 관한 연구 (A Study of the Comparison Analysis for the Rocket Motor Impulse Noise by the Indoor Sizes)

  • 송기혁;정성학;강우람;이덕주;박종호
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.85-90
    • /
    • 2014
  • The purpose of this study is to analysis the 3 differential size of the interior space for impulse noise. To achieve this goal the 3 kinds (27, 35, $50m^3$) of interior space were performed comparing the impulse noise. Result of this study, the standard error of the mean peak sound pressure of value from 0.19 to 0.27dB and there was no significant difference (p<0.01). And B-duration is significant differences (P<0.01) range from 3.98 to 7.93ms. This is respectively less than 10ms. These findings are confirmed in accordance by the 3 differential space size of the indoor-impulse noise due to 0.3 dB or less, so there was no difference to the operational influence. And also below 100 Hz were found fundamental mode frequency analysis. Results were matched with calculated theoretical values.

실내 충격소음 측정시스템 구현에 관한 연구 (A study of the measurement systems implementation for the interior impulse noise)

  • 송기혁;정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.93-100
    • /
    • 2014
  • 본 연구의 목적은170dB 이상의 고충격 소음원에서 실내 충격소음을 측정 평가 할 수 있는 측정시스템 구축 방법을 제안하는데 있다. 이러한 목적을 달성하기 위하여 실내충격소음 측정시스템용 시험장을 설계 및 구현하고, 충격소음 측정용 마이크로폰, Head & Torso Simulator, Ear Simulator를 구성하였다. 충격소음 측정 시 정확한 측정을 위하여 3가지 측정방법을 동시에 측정할 수 있도록 구현하였으며, 정확성과 신뢰성을 위하여 3가지의 실내충격소음 측정값을 상호 비교하였다. 3가지 측정방법에 따른 최대 음압레벨과 옥타브 밴드 결과를 비교 분석함으로써 실내 충격소음의 주파수 특성에 따른 차이점을 확인하였다. 이러한 결과는 반사파의 영향에 의한 것으로 판단된다. 이에, 시험장의 크기를 변형하면서 측정할 수 있도록 실내 충격소음 측정시스템을 구현하였다. 본 시스템 구현을 통하여, 충격 소음원의 특징분석과 해당 주파수별 스펙트럼의 반사파 영향들을 파악할 수 있을 것이며, 향후, 실내 충격소음에 대한 데이터 획득 및 분석을 위하여 유용하게 활용될 수 있을 것으로 판단된다.

폭발파 모델을 이용한 실내 음장 해석에 관한 연구 (Study on the Indoor Acoustic Field Analysis using the Blast Wave Model)

  • 송기혁;강우람;이덕주;김영남
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.142-150
    • /
    • 2015
  • A portable recoilless guided missile generates a strong back blast and impulsive noise at the nozzle when it launches. In the case of indoor operations, the hazard of the blast noise from a recoilless weapon increases due to limited indoor spaces. Also, the noise levels determine the operational feasibility of a weapon; therefore, it is important to predict the blast noise levels distribution in the indoor space in advance. In addition, computational fluid dynamics (CFD) method generally used for fluid related simulations, requires high computing cost and time to simulate the whole domains. The domain includes both blast wave region and large and various indoor space region. Therefore, an efficient method for predicting the far-field noise level within a short time should be developed. This paper describes an analysis model for predicting the indoor noise distributions by considering the shape effect of the building within a short time. A new developed blast wave model was implemented using the noise source. Additionally, noise reflections at the closed surfaces such as walls and noise transmissions at the opened surfaces such as windows and doors were considered in calculating the noise levels. The predicted noise levels were compared with the experimental data obtained from the indoor launch test to validate the reliability of program.

Relative azimuth estimation algorithm using rotational displacement

  • Kim, Jung-Ha;Kim, Hyun-Jun;Kim, Jong-Su;Lee, Sung-Geun;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.188-194
    • /
    • 2014
  • Recently, indoor localization systems based on wireless sensor networks have received a great deal of attention because they help achieve high accuracy in position determination by using various algorithms. In order to minimize the error in the estimated azimuth that can occur owing to sensor drift and recursive calculation in these algorithms, we propose a novel relative azimuth estimation algorithm. The advantages of the proposed technique in an indoor environment are that an improved weight average filter is used to effectively reduce impulse noise from the raw data acquired from nodes with inherent errors and a rotational displacement algorithm is applied to obtain a precise relative azimuth without using additional sensors, which can be affected by electromagnetic noise. Results from simulations show that the proposed filter reduces the impulse noise, and the acquired estimation error does not accumulate with time by using proposed algorithm.

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

Blind Signal Processing for Medical Sensing Systems with Optical-Fiber Signal Transmission

  • Kim, Namyong;Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 2014
  • In many medical image devices, dc noise often prevents normal diagnosis. In wireless capsule endoscopy systems, multipath fading through indoor wireless links induces inter-symbol interference (ISI) and indoor electric devices generate impulsive noise in the received signal. Moreover, dc noise, ISI, and impulsive noise are also found in optical fiber communication that can be used in remote medical diagnosis. In this paper, a blind signal processing method based on the biased probability density functions of constant modulus error that is robust to those problems that can cause error propagation in decision feedback (DF) methods is presented. Based on this property of robustness to error propagation, a DF version of the method is proposed. In the simulation for the impulse response of optical fiber channels having slowly varying dc noise and impulsive noise, the proposed DF method yields a performance enhancement of approximately 10 dB in mean squared error over its linear counterpart.

실내 무선 채널에서 전력검출 기반 Noncoherent OOK UWB 시스템의 성능 분석 (Performance Analysis of a Noncoherent OOK UWB System Based on Power Detection in Indoor Wireless Channels)

  • 오종옥;양석철;신요안
    • 한국통신학회논문지
    • /
    • 제29권11C호
    • /
    • pp.1498-1509
    • /
    • 2004
  • 본 논문에서는 향후 유비쿼터스 센서 네트워크 응용 등에 적합하도록 간단한 송수신기 구조를 유지하면서, 실제 데이터를 전송하기 전에 Noise Power Calibration 및 Noise Power Windowing 방법을 통해 잡음의 영향을 고려하여 적응적인 임계값을 결정하고 이를 이용하여 전력검출 (Power Detection)을 수행하여 성능을 향상하는 임펄스 라디오 (Impulse Radio) 형태의 Noncoherent OOK (On-Off Keying) UWB (Ultra Wide Band) 시스템을 제시하고, 전형적인 UWB 실내 무선 채널 모델에서의 성능을 분석하였다. 모의실험 결과 AWGN (Additive White Gaussian Noise) 채널에서는 Noise Power Calibration 모드를 위한 슬롯수의 증가에 따라 이상적인 Ideal Adaptive Threshold를 사용하는 경우께 근접하는 우수한 성능을 보임을 확인할 수 있었고, 반면 데이터 전송률의 큰 감소를 감수해야 하는 Noise Power Windowing 방법에 의한 성능 개선은 두드러지게 나타나지 않음을 알 수 있었다. 더욱이 IEEE 802.15 Task Group 3a UWB 실내 채널 모델을 이용한 모의실험 결과, Noise Power Calibration 모드가 적용된 Noncoherent OOK UWB 시스템의 성능이 Ideal Adaptive Threshold의 경우와 비트오율 성능이 매우 근접하며, 펄스 반복 전송의 회수의 증가에 따라 비트오율 성능이 향상됨을 확인 할 수 있었다.

청각 보호 장구의 실내 충격소음 차음성능에 관한 연구 (A study of the Indoor-Impulse Noise Attenuation Effect for the Hearing Protection Devices)

  • 정성학;송기혁
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권5호
    • /
    • pp.37-42
    • /
    • 2014
  • 본 연구의 목적은 170 dB 수준의 충격 소음원에서 주파수별 귀마개의 차음성능을 확인하고, 주파수 특성과 패턴 형상을 분석하는데 있다. 충격 소음에서의 Combat Arm Earplug와 3M Form types 1100 Earplug의 주파수별 귀마개 차음성능을 산출하였다. 차음성능을 확인하기 위해서 B&K Head and Torso Simulator와 Ear Simulator를 제작하여 충격 소음원의 주파수별로 차음성능을 비교하였다. 기존의 연구들은 충격 소음원이라 할지라도 대부분 140 dB 수준의 고충격 소음원이였으나, 본 연구는 그보다 더 높은 수준의 충격 소음원이라는 특징을 가지고 있다. 연구결과, 주파수별 충격소음의 차음효과는 평균 28.58 dB 인 것으로 나타났다.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

DFT를 이용한 잔향이 긴 음향 전달계의 임펄스 레스폰스 추정에 관한 연구 (The Comparative Study of the Methods Estimating the Impulse Response of a System with Long Reverberation Time using Discrete Fourier Transform (DFT))

  • 김천덕
    • 한국음향학회지
    • /
    • 제7권2호
    • /
    • pp.26-38
    • /
    • 1988
  • 이 논문은 긴 잔향을 갖는 실내의 음향전달계의 임펄스 레스폰스를 DFT(Discrete Fourier Transform)의 알고리즘으로 크로스 스펙트럼 (cross spectrum method)에 의해 구하는 3가지 방법에 대해 기술한다. 첫째의 방법은 종래부터 사용되어온 방법으로 음원신호로서 백색잡음(white noise)을 사용한다. 따라서, 임펄스 레스폰스 추정시 매우 긴 시간창의 데이터와 다수회의 DFT를 행하여야 한다. 두번째 방법은 음원신호로써 짧은 지속시간의 랜덤노이즈(random noise)를 사용하여 첫번째 방법에서 DFT수행시 데이타의 시간창의 길이를 짧게 하기 위하여 개발된 방법이다. 세번째 방법은 본 논문에서 제안한 방법으로 음원신호로써 짧은 지속시간의 두 종류의 확정산호를 교차하여 발생하는 방법이다. 이 방법은 DFT수행시 시간창의 길이는 두번째 방법과 같고 FFT 계산횟수는 5번으로 행할 수 있다. 이들 음원신호에 대해 잔향이 긴 음향전달계의 임펄스 레스폰스 측정은 전자계산기의연산처리능력과 임펄스 레스폰스 측정정도의 관점에서 비교 시험한 결과는 마지막 방법이 가장 유리하다는 결론을 얻었다.

  • PDF