References
- Castleman, K.R. (1996) Digital Image Analysis. Prentice Hall, New Jersey
- Chatfield, C. (1996) The Analysis of Time Series-an introduction, Chapman & Hall, London
- Chow, W.K., W.Y. Fung, and L.T. Wong (2002) Preliminary studies on a new method for assessing ventilation in large spaces, Building and Environment, 37, 145-152 https://doi.org/10.1016/S0360-1323(01)00020-8
- Drescher, A.C., D.Y. Park, M.G. Yost, A.J. Gadgil, S.P. Levine, and W.W. Nazaroff (1997) Stationary and time-dependent indoor tracer-gas concentration profiles measured by OP-FTIR remote sensing and SBFM-computed tomography, Atmospheric Environment, 31(5), 727-740 https://doi.org/10.1016/S1352-2310(96)00221-X
- Etheridge, D. and M. Sandberg (1996) Building Ventilation: theory and measurement, John Wiley & Sons, Chichester, U.K
- Fischer, M.L., P.N. Price, T.L. Thatcher, C.A. Schwalbe, M.J. Craig. E.E. Wood, R.G. Sextro, and A.J. Gadgil (2001) Rapid measurements and mapping of tracer gas concentrations in a large indoor space, Atmospheric Environment, 35, 2837-2844 https://doi.org/10.1016/S1352-2310(01)00081-4
- Hong, J.H., J.H. Lee, and S.S. Park (2007) Application of an in-situ measurement system to determine HONO levels in an indoor environment, Journal of Korean Society for Atmospheric Environment, 23(2), 191-202 https://doi.org/10.5572/KOSAE.2007.23.2.191
- Jayaraman, B., E.U. Finlayson, M.D. Sohn, T.L. Thatcher, P.N. Price, E.E. Wood, R.G. Sextro, and A.J. Gadgil (2006) Tracer gas transport under mixed convection conditions in an experimental atrium: Comparison between experiments and CFD predictions, Atmospheric Environment, 40, 5236-5250 https://doi.org/10.1016/j.atmosenv.2006.04.021
- Kamen, E.W. and B.S. Heck (1997) Fundamentals of Signals and Systems-using MATLAB, Prentice Hall, New Jersey
- Karlsson, J.F. and B. Moshfegh (2007) A comprehensive investigation of a low-energy building in Sweden, Renewable Energy, 32, 1830-1841 https://doi.org/10.1016/j.renene.2006.10.009
- Kim, S.D., T.S. Kim, H. Lee, and J.J. Lee (1993) The spatial characteristics of ventilation efficiency, Journal of Korean Society for Atmospheric Environment, 9(3), 236-241
- Lagus, P.L. (1977) Characterization of building infiltration by the tracer-dilution method, Energy 2(4), 461-464 https://doi.org/10.1016/0360-5442(77)90009-3
- Lee, H. (1993) Study on the Influence of Ventilation on Indoor Air Pollutant Removal, Master Thesis, the University of Seoul, Seoul
- Lee, H. and H.B. Awbi (1998) Effect of data logging frequency on tracer gas measurement. In Proceedings of the Roomvent '98, KTH-Royal Institute of Technology, Stockholm, Sweden, June 14-17, Vol. 2, 477-482
- O'Neill, P.J. and R.R. Crawford (1991) Identification of flow and volume parameters in multizone systems using a single-gas tracer technique, ASHRAE Transactions, Vol. 97, 49-54
- Phillips, D. and G. Bragg (1994) The measurement of high frequency variations in concentrations of indoor air constituents. ASHRAE Transactions, Vol. 100, 1225-1229
- Ramirez, R.W. (1985) The FFT-fundamentals and concepts, Prentice Hall, New Jersey
- Said, M.N.A. (1997) Measurement of air change rates and air flow patterns in large single-cell buildings, Energy and buildings, 26, 175-182 https://doi.org/10.1016/S0378-7788(96)01032-8
- Sandberg, M. and H. Stymne (1989) The constant tracer flow technique, Building and Environment, 24(3), 209-219 https://doi.org/10.1016/0360-1323(89)90034-6
- Sherman, M.H. (1989a) Analysis of errors associated with passive ventilation measurement techniques. Building and Environment 24(2), 131-139 https://doi.org/10.1016/0360-1323(89)90002-4
- Sherman, M.H. (1989b) Uncertainty in air flow calculations using tracer gas measurements, Building and Environment, 24(4), 347-354 https://doi.org/10.1016/0360-1323(89)90029-2
- Signal Processing Toolbox User's Guide (v4.2) (1998) Mathworks Inc., Massachusetts
- Sohn, M.D. and M.J. Small (1999) Parameter estimation of unknown air exchange rates and effective mixing volumes from tracer gas measurements for complex multi-zone indoor air models, Building and Environment, 34, 293-303 https://doi.org/10.1016/S0360-1323(98)00022-5