• Title/Summary/Keyword: indoor test

Search Result 774, Processing Time 0.02 seconds

Application of the Extract of Zanthoxylum piperitum DC to Manufacturing Eco-friendly Antimicrobial Interior Fabric Blind Materials (초피 추출물을 이용한 친환경 항균 실내 직물 블라인드 소재 개발)

  • Xie, Li Rui;Jun, Do Youn;Park, Ju Eun;Kwon, Gi Hyun;Cho, Bonggeun;Park, Hyun Woo;Lee, Chang Woo;Kim, Chang Young;Jung, Hyo-Il;Kim, Young Ho
    • Journal of Life Science
    • /
    • v.26 no.8
    • /
    • pp.936-942
    • /
    • 2016
  • As the incidence of environmental diseases is increasing due to harmful environmental factors, there is a rising interest in developing eco-friendly materials for housing. In this study, we sought to develop antimicrobial interior fabric blind materials by employing ethanol extract of a medicinal plant Zanthoxylum piperitum DC. As determined by the disc diffusion method, the zones of inhibition of the pericarp ethanol extract at a concentration of 5 mg/disc against Klebsiella pneumoniae, Staphylococcus aureus, and Streptococcus mutans were 13.5±1.5 mm, 14.0±0.5 mm and 15.0±0.1 mm, respectively, whereas the leaf ethanol extract (5 mg/disc) against K. pneumoniae, S. aureus, and S. mutans were 12.8± 0.3 mm, 13.5±1.0 mm, and 12.0±0.1 mm, respectively. The IC50 of the leaf ethanol extract against K. pneumoniae, S. aureus and S. mutans were about 0.5 mg/ml, 0.1 mg/ml and 1.0 mg/ml respectively. To examine whether the leaf ethanol extract possessing antibacterial activity of Z. piperitum DC can be applicable to production of antimicrobial fabric blind materials, the fabrics treated with either 1.0% or 2.0% of the leaf ethanol extract were tested for antibacterial activity against K. pneumoniae and S. aureus using International Standard Fabrics Test Method. The results indicate that the fabric treated with the ethanol extract of Z. piperitum DC possesses an excellent antimicrobial activity against both pathogenic bacteria. These results suggest that Z. piperitum DC may be applicable to producing functional fabrics which are effective in reducing the harmful bacterial factors in indoor environments.

Middle Schooler's Perception of the Unit "Housing Education" of the 9th Grade Technology and Home Economics (주생활 영역 학습에 대한 중학생의 인식)

  • Choi, Hyun-Suk;Jang, Sang-Ock
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.3
    • /
    • pp.1-16
    • /
    • 2008
  • The purpose of this study is to investigate the perception of middle schooler's lesson of 9th grade "Housing Education" Questionnaire survey was conducted with 394 middle school students in Gyeongnam in 2006 and the dada analyzed by the descriptive statistics, t-test, One-way ANOVA, Duncan's multiple range test, Pearson correlation and multiple regression analysis by using SPSS 14. program. The result of this study were as follows. The unit 'Use of dwelling space' was perceived useful in real life, interesting in explanation & visual materials of the text, taught easily to understand the students and ranked highest in class satisfaction compared with the rest two units. The unit 'Indoor environment & equipment' was least interesting, most difficult and ranked lowest in class satisfaction. The unit 'House management & repair' was relatively interesting and easy, but not useful in real life, not much interesting in explanation & visual materials in text, taught difficult by teachers. The class satisfaction ranked second of the units. Female students perceived that the unit 'Use of dwelling space' was easy, but male students perceived that all the units were interesting in the explanation & visual materials in textbook, various teaching-learning methods, interesting experiment & practice, and was satisfied with the unit 'House management & repair'. As their academic achievement of "Technology & Home Economics" was lower, they perceived that the education contents and various experiment & practice were more difficult. The class satisfaction of middle schoolers about the unit "Housing Education" were affected by how easily the teacher taught the subject, making it more understandable, the level of difficulty of the contents and the level of interest of explanation & visual materials of text.

  • PDF

Experiments on Flow Characteristics of Asphalt Seal Composite Waterproofing Method for Underground Concrete Structure Exterior Wall Waterproofing (지하 콘크리트 구조물 외벽 방수용 아스팔트 씰재 복합방수 공법의 흘러내림 특성에 관한 실험)

  • Ko, Sang-Ung;Kim, Kyoung-Hoon;Kim, Young-Sam;Shin, Hong-Chul;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.297-303
    • /
    • 2018
  • With the changing trend of the building construction to high rising and large scaling, the underground structure has been increased, and its usage also increased and variety. Hence, to protect the underground structure against underground water, various water proofing methods has been developed. Among the many water proofing methods, the combined water proofing method using both asphalt seal and sheet has been widely used to secure the sufficient performance and decrease the construction failure. However, during the summer period of extremely high temperature conditions, the asphalt sealing materials were separated and leaked into the structure. Therefore, the aim of the research is to provide the quality standard of asphalt sealing material based on the various temperature changes depending on seasons. According to the experimental results, the temperature of the sealing materials applied on the slab was increased up to $54^{\circ}C$ which was $3^{\circ}C$ higher than the structure temperature of $51^{\circ}C$. Based on the melting test for asphalt sealing materials applied on the outside wall of the structure, in the case of water-dispersing typed materials showed significant melting down due to its slow evaporation and low viscosity. Furthermore, from the accelerated test conducted indoor conditions, a solvent-type and water-dispersing typed materials showed significant melting down due to their low viscosity and melting point in ambient conditions. Based on these results, viscosity and melting point are found as the important factors on asphalt sealing materials' quality, and it is necessary to designate the quantitative level of the viscosity and melting point for quality control.

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.