• Title/Summary/Keyword: indoor space

Search Result 962, Processing Time 0.032 seconds

A Study on the Estimate of Thermal Environment and the Subjective Responses of the Aged during Summer in the Welfare Facilities -Focused on the Welfare Facilities for the Aged in Taegu- (노인복지시설의 하절기 실내 온열환경과 노인의 주관적 반응평가에 관한 연구 -대구광역시 소재 노인복지시설을 중심으로)

  • 이형우;홍원화
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 2002
  • The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.

Indoor Localization Method using Single Inertial and Ultrasonic Sensors (단일 관성 센서와 초음파를 이용한 실내 위치추정 방법)

  • Ryu, Seoung-Bum;Song, Chang-Woo;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.115-122
    • /
    • 2010
  • Most of intelligent services provided today work based on the users' location. Numerous devices for indoor localization services have their own characteristic functions and operating systems, we need the interoperability and diversity of middleware to connect and control these devices. The indoor localization method using existing inertial sensors are relatively less efficient because of additional cost according to the size of space. Accordingly, the indoor user localization method proposed in this study supports integrated services using OSGi framework, an open source project, and solves problems in inertial sensor based on accurate distance to a specific object measured using ultrasonic sensor. Furthermore, it reduces errors resulting from difference in response rate by adding the reliability item.

A Study on Indoor Air Pollutants Reduction Effect by Plants per Season (식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구)

  • Song, Jeong Eun;Kim, Yong Shik;Sohn, Jang Yeul
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

Development of Air Cleaning System for Railroad Vehicles (차세대 객차용 청정시스템 개발)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2109-2113
    • /
    • 2008
  • As the standard of living is higher, the passengers using public transportations desire better qualities of environment as well as more comfortable indoor environment. In case of train, the passengers' comfort in passenger cabin is one of the most important elements to be competitive with other transport systems. The indoor air quality of the cabin should be managed properly, because many passengers travel for a long time in the small space of $144\;m^3$. For proper management of the air quality, the heating, ventilation and air conditioning (HVAC) system is required for the ventilation of the compartment. To maintain comfortable environment in the compartment, the automatic ventilation system is needed to exchange the indoor air with fresh air or clean indoor air. In this study, we investigated the indoor air quality (PM-10, $CO_2$, and VOCs) in the compartment of train. In addition, type and pattern of PM-10 has been analyzed through the clustering analysis. Based on the analysis, we could found that the fine particulate matters in the compartment can be a serious hazard to human. To control the concentration of PM-10 and $CO_2$ air cleaners were developed. Through this study, it is expected that people who take a train will be in a more comfortable environment.

  • PDF

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

Indoor Mobile Localization System and Stabilization of Localization Performance using Pre-filtering

  • Ko, Sang-Il;Choi, Jong-Suk;Kim, Byoung-Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.2
    • /
    • pp.204-213
    • /
    • 2008
  • In this paper, we present the practical application of an Unscented Kalman Filter (UKF) for an Indoor Mobile Localization System using ultrasonic sensors. It is true that many kinds of localization techniques have been researched for several years in order to contribute to the realization of a ubiquitous system; particularly, such a ubiquitous system needs a high degree of accuracy to be practical and efficient. Unfortunately, a number of localization systems for indoor space do not have sufficient accuracy to establish any special task such as precise position control of a moving target even though they require comparatively high developmental cost. Therefore, we developed an Indoor Mobile Localization System having high localization performance; specifically, the Unscented Kalman Filter is applied for improving the localization accuracy. In addition, we also present the additive filter named 'Pre-filtering' to compensate the performance of the estimation algorithm. Pre-filtering has been developed to overcome negative effects from unexpected external noise so that localization through the Unscented Kalman Filter has come to be stable. Moreover, we tried to demonstrate the performance comparison of the Unscented Kalman Filter and another estimation algorithm, such as the Unscented Particle Filter (UPF), through simulation for our system.

Experimental Study on the Operating Characteristics of a Solar Hybrid Heat Pump System according to Indoor Setting Temperature (실내설정온도에 따른 태양열 하이브리드 열펌프 시스템 운전특성에 대한 실험적 연구)

  • Kim, Won-Seok;Cho, Hong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.50-58
    • /
    • 2010
  • Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature were carried out during spring and winter season. The system was consisted of a concentric evacuated tube solar collector, heat medium tank, heat storage tank, and heat pump. As a result, the heating load was increased by 21.1% when the indoor setting temperature rose by 2oC for the same ambient temperature. Besides, the spring season had good outdoor conditions compared to the winter season, therefore the heating load was reduced and heat gain by collector increased, relatively. In case of the winter season, the solar fraction was shown less than 10% because the heat losses of system and space increased considerably. The solar fraction decreased significantly as the indoor setting temperature increased.

A Study about Indoor Environmental Improvement of Green Building Certification System through, POE (거주 후 평가를 통한 친환경 인증제도의 실내환경 개선 방향에 대한 연구)

  • Lee, Myung-Joon;Lee, Jong-Chan;Kim, Kwoang-Ho;Kim, Byung-Sean
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1055-1060
    • /
    • 2006
  • The Korean Green Building Certification System was activated from 2005. The purpose of it is to improve the quality of residential unit. Recently, people stay inside of building more than for 90% of a day Accordingly, it is really important for them to make the quality of Indoor Environmental better, in brief, to develop the indoor environmental factor in KGBC is important. One of the best way to develop the system is to do research based on POE because the area of problem can be realized. Accordingly, we get the information about POE from another research for the part of the indoor environment for residential unit to have the critical mind about the KGBC, and tried to compare the factors to another which is from foreign Green Building Certification System such as LEED, BREEAM, GBTool, After they have been analyzed, we could find that some of factor need to be revised and added. Also, there was one problem that many part of factor was created without any consideration of direction of each space in residential unit.

  • PDF

PRACTICAL USE OF INDOOR SPATIAL DATABASE

  • Wenyuan Luo;Yoon-Sun Lee;Jae-Jun Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1491-1496
    • /
    • 2009
  • Because of the development of advanced construction technology, the inner environments of building become more and more complicated, which may result in many problems. The administer may forget where they put up the certain picture, and search for it all over the building, or they underestimate the number of the visitors, and find the situation is out of control, while the pedestrian may get lost, and after making their efforts, they found they turned back to the origin point again. So it is very necessary to establish an indoor spatial database. On one hand, it is able to assist administrator to manage the property and human flow inside the building, on the other hand it could help the pedestrian find the way easily especially when they are not familiar with the building or there is an emergency. This paper focused on how to create the indoor spatial database including both static database and moving objects database. The static database is built on the basis of 3D building models, and the moving objects database gets information from many kinds of cameras and sensors installed in the building. And at the same time the paper discussed the practical use of indoor spatial database mainly in three aspects including consistency management, building restructure, and pedestrian navigation.

  • PDF

A Study on the Importance and Performance of the Display of Dining Space for Hotel Banquets (호텔 연회 식공간 연출에 대한 중요도와 만족도 분석 연구)

  • Kim, Gi-Chul;Lee, Yeon-Jung
    • Culinary science and hospitality research
    • /
    • v.15 no.2
    • /
    • pp.173-187
    • /
    • 2009
  • The purpose of this study is to provide useful information for establishing efficient marketing direction by investigating the performance(satisfaction) and importance of the display of dining space for hotel banquets. The importance and satisfaction scores of the display of dining space were measured on the five-point Likert scale. The results were summarized as follows. 'Taste of food(4.53 point)', 'freshness of food materials(4.50 point)', and 'indoor cleanliness(4.38 point)' were considered highly important while 'carpet shape of the floor(3.68 point)' and 'art objects(3.69 point)' were scored low. As for the factors of satisfaction, 'freshness of food materials(3.86 point)', 'taste of food(3.85 point)', 'indoor cleanliness(3.74 point)', and 'overall cleanliness of tables(3.73 point)' were considered highly satisfactory while 'art objects(3.42 point)', 'item decoration(3.44 point)', 'furniture and accessory decoration(3.45 point)' were scored low. As a result of analyzing difference between importance and performance of the display of dining space, importance(4.02 point) was much higher than performance(3.60 point). For the IPA result, customers made much account of 'taste of food', 'freshness of food materials', 'indoor cleanliness', 'overall cleanliness of tables', 'cleanliness state of a banquet hall' and so on, so they were regarded as the items to be continuously cared for. Also, intensive care was needed in such factors as 'indoor temperature', 'food vessels', 'soundproofing' and 'colors of a banquet hall' due to low customer satisfaction.

  • PDF